• Title/Summary/Keyword: Force sensing resistor

Search Result 33, Processing Time 0.028 seconds

Algorithm development of a body pressure detection sensor for the occupant classification system (고안전 에어백의 승객 분류를 위한 체압감지 센서를 위한 알고리즘 개발)

  • Yun, Duk-Sun;Oh, Seong-Rok;Song, Jeong-Hoon;Kim, Byeong-Soo;Boo, Kwang-Suck
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.385-392
    • /
    • 2009
  • This paper describes the algorithm development of a new body pressure detection sensor for occupant classification system. U.S. Government has required that advanced airbag system should be installed to every automobiles after 2006 according to FMVSS 208 regulation. Therefore, Occupant Classification System should be provided the passenger with safety in order to protect the infants or children that sit in the front passenger seat. When an occupant sits on the chair of the vehicle, deployment of the airbag depends on passenger's weigh distribution and postures. Authors have been developed a new pattern recognition of passenger and weight distribution at the same time by Force Sensing Resistor for the safety.

Design and Implementation of a Readout Circuit for a Tactile Sensor Pad Based on Force Sensing Resistors (FSR로 구성된 촉각 센서 패드용 Readout 회로의 설계 및 구현)

  • Yoon, Seon-ho;Baek, Seung-hee;Kim, Cheong-worl
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.331-337
    • /
    • 2017
  • A readout circuit for a tactile sensor pad based on force sensing resistors was proposed, which was composed of an analog signal conditioning circuit and a digital circuit with a microcontroller. The conventional signal conditioning circuit has a dc offset voltage in the output signal, which results from the reference voltage applied to the FSR devices. The offset voltage reduces the dynamic range of the circuit and makes it difficult to operate the circuit under a low voltage power supply. In the proposed signal conditioning circuit, the dc offset voltage was removed completely. The microcontroller with A/D converter and D/A converter was used to enlarge the measurement range of pressure. For this, the microcontroller adjusts the FSR reference voltage according to the resistance magnitude of FSR under pressure. The operation of the proposed readout circuit which was connected to a tactile sensor pad with $5{\times}10$ FSR array was verified experimentally. The experimental results show the proposed readout circuit has the wider measurement range of pressure than the conventional circuit. The proposed circuit is suitable for low voltage and low power applications.

Analysis and Design of Humanoid Robot Foot using the Design of Experiments (실험 계획법을 이용한 휴머노이드 발의 설계 및 해석)

  • Yoo, Young-Kuk;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1791-1792
    • /
    • 2008
  • 휴머노이드 로봇은 기구적으로 불안정성을 내포하고 있기 때문에 이것에 대한 안정화를 하기 위해서 연구자들은 많은 방법을 사용하고 있다. 본 연구자는 실험 계획법(Design of Experiments)을 통해 본 연구자가 개발한 ISHURO-II의 발의 설계를 변경하였다. 퍼지 알고리즘을 이용하여 아랫부분에 장착된 FSR(Force Sensing Resistor)센서에서 ZMP(Zero Moment Point)의 값을 비교하여 더욱 안정된 보행이 가능하도록 하였다. 적용된 안정화 알고리즘의 성능은 VC++ 및 동역학 해석 프로그램을 이용한 시뮬레이션을 통해 검증하였다.

  • PDF

A Study on the Design of DC Parameter Test System (DC 파라메터 검사 시스템 설계에 관한 연구)

  • 신한중;김준식
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.2
    • /
    • pp.61-69
    • /
    • 2003
  • In this paper, we developed the U parameter test system which inspects the property of DC parameter for semiconductor products. The developed system is interfaced by IBM-PC. It is consisted of CPLD part, ADC (Analogue to Digital Converter), DAC (Digital to Analogue Converter), voltage/current source, variable resistor and measurement part. In the proposed system, we have designed the constant voltage source and the constant current source in a part. The CPLD part is designed by VHBL, which it generates the control and converts the serial data to parallel data. The proposed system has two test channels and it operates VFCS mode and CFVS mode. The range of test voltage is from 0[V] to 100[V], and the range of test current is from 0[mA] to 100[mA)]. The diode is tested. The test results have a good performance.

  • PDF

Development of Anthropomorphic Robot Hand with Tactile Sensor: SKKU Hand II (촉각센서를 갖는 인간형 로봇손의 개발: SKKU Hand II)

  • Choi Byung-June;Lee Sang-Hun;Kang Sung-Chul;Choi Hyouk-Ryeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.6
    • /
    • pp.594-599
    • /
    • 2006
  • In this paper an anthropomorphic robot hand called SKKU Hand IIl is presented, which has a miniaturized fingertip tactile sensor. The thumb is designed as one part of the palm and multiplies the mobility of the palm. The fingertip tactile sensor, based on polyvinylidene fluoride (PVDF) and pressure variable resistor ink, is physically flexible enough to be deformed into any three-dimensional geometry. In order to detect incipient slip, a PVDF strip is arranged along the direction normal to the surface of the finger of the robot hand. Also, a thin flexible sensor to sense the static force as well as the contact location is fabricated into an arrayed type using pressure variable resistor ink. The driving circuits and the tactile sensing systems for the SKKU Hand II are embedded in the hand. Each driving circuit communicates with others using CAN protocol. SKKU Hand II is manufactured and its feasibility is validated through preliminary experiments.

A Study on Walking Stabilization and Path Tracking of Biped Robot Using RFID (이족 보행 로봇의 보행 안정화 및 RFID를 이용한 경로 추종에 관한 연구)

  • Park, Jong-Han;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • In order to apply a biped robot in real world, the robot requires a robust walking and a function of localization, path planning and navigation. Recently, localization and path planning using RFID of mobile robot has been studying. However, when the biped robot walks, it has unstability and tends to leave the path. In the paper we propose a method of walking stabilization using FSR(Force Sensing Resistor), Gyro and accelerometer for the real biped robot. Also a path tracking algorithm using RFID sensor attached in robot's foot is proposed based on localization of the robot. The proposed algorithm is verified from walking experiments using real biped robot on uneven terrain and path tracking experiments on the RFID environments.

Detection of Implicit Walking Intention for Walking-assistant Robot Based on Analysis of Bio/Kinesthetic Sensor Signals (보행보조로봇을 위한 다중 생체/역학 센서의 신호 분석 및 사용자 의도 감지)

  • Jang, Eun-Hye;Chun, Byung-Tae;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.294-301
    • /
    • 2010
  • In order to produce a convenient robot for the aged and the lower limb disabled, it is needed for the research detecting implicit walking intention and controlling robot by a user's intention. In this study, we developed sensor module system to control the walking- assist robot using FSR sensor and tilt sensor, and analyzed the signals being acquired from two sensors. The sensor module system consisted of the assist device control unit, communication unit by wire/wireless, information collection unit, information operation unit, and information processing PC which handles integrated processing of assist device control. The FSR sensors attached user's the palm and the soles of foot are sensing force/pressure signals from these areas and are used for detecting the walking intention and states. The tilt sensor acquires roll and pitch signal from area of vertebrae lumbales and reflects the pose of the upper limb. We could recognize the more detailed user's walking intention such as 'start walking', 'start of right or left foot forward', and 'stop walking' by the combination of FSR and tilt signals can recognize.

Development of Sensory Feedback System for Myoelectric Prosthetic Hand (전동의수 사용자를 위한 감각 측정 및 전달 시스템 개발)

  • Bae, Ju-Hwan;Jung, Sung Yoon;Kim, Shinki;Mun, Museong;Ko, Chang-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.851-856
    • /
    • 2015
  • This study aimed to develop a sensory feedback system which could measure force and temperature for the user of myoelectric prosthetic hands. The Sensory measurement module consisted of a force sensing resistor to measure forces and non-contact infrared temperature sensor. These sensors were attached on the fingertips of the myoelectric prosthetic hand. The module was validated by using standard weights corresponding to external force and a Peltier module. Sensory transmission module consisted of four vibration motors. Eight vibration patterns were generated by combining motion of each vibration motor and were dependent on kinds and/or magnitude. The module was verified by using standard weigts and water at varying temperatures. There were correlations of force and temperature between the sensory measurement module and standard weight and water. Additionally, exact vibration patterns were generated, indicating the efficacy of the sensory feedback system for the myoelectric prosthetic hand.

Measurement and analysis of body pressure distribution on a bed

  • 박세진;황민철;김창범
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.55-61
    • /
    • 1995
  • We spend about 40% of lifte time on a bed and seek how such amount of time is spent comfort. Bed comfort has been pursuited. The pressure distributions on a bed by body pressure has been considered as one of the most important factors of bed comfort. This study is to quantify the subjective assessment by the body pressure distribution and develop the objective evaluation method of bed comfort. A new measurement system for body pressure on a bed was developed in this study. The thin film pressure sensor (FSR: Force Sensing Resistor) of an elastomer-type was used to prevent the distortion of contact pressure. The pressure distribution is measured by FSR and displayed on the monitor by color-coded contour patterns. Some of the bed test results were described. And the relations between body pressure distribution and bed comfort were evaluated.

  • PDF