• 제목/요약/키워드: Fluorescent

검색결과 3,058건 처리시간 0.048초

Fluorescent Compounds Having the Spaced and Integrated Type Receptors

  • Choi, Chang-Shik
    • Rapid Communication in Photoscience
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2016
  • Fluorescent receptors have gained much attention because of their usefulness in analysis and clarification of the roles of biomolecules in living systems. Molecular structures of the integrated type including that the receptor itself is fluorescent, and play an important role in having the functionality or selectivity of the fluorescent compounds. These spaced type fluorescent receptors are required to have special molecular design in order to transmit the information of molecular recognition to the fluorescent unit through the spacer unit. Compared with the spaced type fluorescent receptors, number of the integrated type receptors is limited due to the difficult molecular design and synthesis. Modification of alteration of the fluorophore frequently caused deterioration of the fluorescent property. Various spaced type and integrated type fluorescent receptors including switch on-off receptors are introduced in this article.

Expression of various fluorescent protein and their production in shake flasks

  • Park, So-Jung;Han, Kyung-Ah;Rhee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.408-411
    • /
    • 2005
  • 대장균을 이용하여 형광단백질을 형질전환하고 배양하면서 그 특성을 관찰하고 형광세기 및 형광 단백질의 크기를 조사하였다.

  • PDF

꽃게 통발용 미끼 및 미끼통의 형광 특성 (Fluorescent characteristics of baits and bait cages for swimming crab Portunus trituberculatus pots)

  • 장호영;구재근;이근우;조봉곤;정병곤
    • 수산해양기술연구
    • /
    • 제44권3호
    • /
    • pp.174-183
    • /
    • 2008
  • In order to develop the substitutive materials for natural baits of swimming crab pots, the fluorescent characteristics of the baits were analyzed, and the preference of fluorescent dyes were investigated by the mean entrapped catch number to the pots through the water tank experiments and fishing experiments. On the investigation of fluorescent characteristics by the 5 kinds of baits, mackerel, krill, manila clam, pig's fat and chicken's head which were used in substitutive baits for test in the UV long wave(365nm) area, it showed clear blue fluorescence in the skin of mackerel, shell of krill, manila clam and bill of chicken's head, and green fluorescence in the mackerel s muscle and internals, and yellow fluorescence in the pig's fat and chicken's head. On the investigation of fluorescent characteristics by the bait cages in the UV short wave(254nm) and long wave(365nm) area, it showed each green, red and blue fluorescence in the cylinderical or hexahedral red plastic bait cages which were painted each green, red and blue fluorescence dyes, but it showed yellowish green flourescence in the cylinderical or hexahedral red plastic bait cage which was painted yellow fluorescent dye. On the preference investigation of the fluorescent dyes of swimming crabs by the 5 kinds of the bait cages which were put the mackerel in the non-fluorescent red plastic cage($RF_N$), red, yellow, green and blue fluorescent plastic cages(RF, YF, GF, BF) each, nonfluorescent red plastic cage($RF_N$) was entrapped mean 2.0(6.7%), but blue fluorescent plastic cage(BF) was mean 5.0(16.7%) and it was more 2.5 times comparing to $RF_N$, and red fluorescent cage(RF) was same level and green fluorescent cage(GF) was 50% of catch number comparing to $RF_N$, and yellow fluorescent cage(YF) was entrapped nothing(F 46.324, P < 0.05). On the investigation of the entrapped catch number to the pots which were put the mackerel in the blue fluorescent hexahedral plastic cage(HP) and blue fluorescent silicon mackerel model cage(SM), HP was mean 3.4(11.3%) and it was a little more comparing to SM which was entrapped mean 3.2(10.7%)(t 0.775, P > 0.05). Fishing experiments on the preference investigation of swimming crabs by the pots which were put in the non-fluorescent red plastic cage($RF_N$) and blue fluorescent plastic cage(BF) were conducted 3 times. Mean catching number and weight of $RF_N$ were 71.7 ind.(18.3%) and 16.9kg(64.3%), and those of BF were 93.0 ind.(23.1%) and 19.8kg(64.5%), respectively.

형광램프대체용 LED FDL 개발 (Development of The LED FDL for Replacing Fluorescent Lamp)

  • 양병문;장우진;차재상
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

The Recent Current of Fluorescent Polypyridine Compounds Having Photofuctionality

  • Choi, Chang-Shik
    • Rapid Communication in Photoscience
    • /
    • 제5권2호
    • /
    • pp.21-26
    • /
    • 2016
  • Many kinds of fluorescent polypyridine compounds including bpy and dppz derivatives are described in understanding the recent current of fluorescent materials having photofuctionality. Those polypyridine compounds have the photofunctionality such as the fluorescence recognition and/or photo-switching. Furthermore, those compounds are applicated for the construction of long ranged photoinduced electron/energy transfer system. Various fluorescent ${\pi}-conjugation$ systems connected by amide or imine bond as well as the simple fluorescent bpy derivatives are introduced in this review paper.

형광등과 자연광의 광도에 따른 실내조경식물의 생육반응과 도입 방안 (Growth Responses and Introduction Plan of Interior Landscape Plants under Light Intensity of Fluorescent Light and Sunlight)

  • 최경옥;이상우
    • 한국조경학회지
    • /
    • 제33권4호
    • /
    • pp.119-128
    • /
    • 2005
  • This study was carried out to obtain fundamental information of growth response of interior landscape plants under a fluorescent lighting, a sunlight at indoor. Ficus elastica Roxb. vu. decora Hort, Spathiphyllum 'Clevelandii', Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' and Cordyline terminalis Kunth var. red edge Hort were examined under 100lux, 500lux, 1,000lux and 2,000lux light intensity consisted of fluorescent lighting and sunlight at indoor condition. Result of experiments are as follows; 1. A Ficus elastica Roxb. var. decora Hort plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting in cases of all conditions. 2. A Spathiphyllum 'Clevelandii' showed the best effective adaptations under law intensity among experimental plants. A Spathiphyllum 'Clevelandii', plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 1,000lux light intensity of fluorescent lighting in cases of all conditions. 3. It need the best high establishment of fluorescent lighting among experimental plants for good plant growth. A Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status was better showed under high light intensity in case of same light source. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting. 4. A Cordyline terminalis Kunth var. red edge Hort plant growth status was better showed under fluorescent lighting than sunlight. but, A plant growth status was better showed under $500lux\sim1,000lux$ than 2,000lux in cases of all intensity of fluorescent lighting. while, A plant growth status was better showed under $1,000lux\sim2,000lux$ in cases of all intensity of sunlight.

Effect of degumming conditions on the fluorescence intensity of fluorescent silk cocoons: A combined experimental and molecular dynamics study

  • Chan Yeong, Yu;Ezekiel Edward, Nettey-Oppong;Elijah, Effah;Su Min, Han;Seong-Wan, Kim;Seung Ho, Choi
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제45권2호
    • /
    • pp.56-69
    • /
    • 2022
  • Silk is a unique natural biopolymer with outstanding biocompatibility, high mechanical strength, and superior optical transparency. Due to its excellent properties, silk has been widely reported as an ideal biomaterial for several biomedical applications. Recently, fluorescent silk protein, a variant of native silk, has been reported as a biophotonic material with the potential for bioimaging and biosensing. Despite the realization of fluorescent silk, the traditional degumming process of fluorescence silk is crude and often results in fluorescence loss. The loss of fluorescent properties is attributed to the sensitivity of silk fibroin to temperature and solvent concentration during degumming. However, there is no comprehensive information on the influence of these processing parameters on fluorescence evolution and decay during fluorescent silk processing. Therefore, we conducted a spectroscopic study on fluorescence decay as a function of temperature, concentration, and duration for fluorescent silk cocoon degumming. Sodium carbonate solution was tested for degumming the fluorescent silk cocoons with different concentrations and temperatures; also, sodium carbonate solution is combined with Alcalase enzyme and triton x-100 to find optimal degumming conditions. Additionally, we conducted a molecular dynamics study to investigate the fundamental effect of temperature on the stability of the fluorescent protein. We observed degumming temperature as the prime source of fluorescent intensity reduction. From the MD study, fluorescence degradation originated from the thermal agitation of fluorescent protein Cα atoms and fluctuations of amino acid residues located in the chromophore region. Overall, degumming fluorescent silk with sodium carbonate and Alcalase enzyme solution at 25 ℃ preserved fluorescence.

전기천공시스템에서 Propidium Iodide와 Yo-Pro-1의 농도에 따른 세포 생존율과 전달효율 평가 (Evaluation of Cell Viability and Delivery Efficiency in Electroporation System According to the Concentrations of Propidium Iodide and Yo-Pro-1)

  • 배서준;임도진
    • Korean Chemical Engineering Research
    • /
    • 제57권6호
    • /
    • pp.898-906
    • /
    • 2019
  • 본 연구에서는 전기천공시스템에서 형광 염료를 사용한 세포 생존율 평가와 형광 염료를 전달 물질로 하여 세포 내부로의 전달 효율 평가를 통해 세포의 생존율과 전달 물질의 전달 효율 평가에 사용하기 적합한 형광 염료의 선정 및 사용에 적절한 농도에 대한 가이드라인을 제시 할 수 있는 기초 연구를 수행하였다. 형광 염료로는 Propidium Iodide와 Yo-Pro-1을 사용하였다. Propidium Iodide과 Yo-Pro-1을 사용한 세포 생존율 평가와 전달 효율의 평가에서 각 형광염료의 유세포 분석 히스토그램의 모양은 형광 염료의 종류와 사용한 농도에 따라 다른 것을 확인하였다. 이는 사용하는 형광 염료의 특성과 연관이 있는 것으로 이 결과를 통해 세포 분석에 사용하는 형광 염료의 특성에 따라 분석 결과가 달라지는 것을 알 수 있었다. 형광 염료 자체가 세포 생존률에 미치는 영향은 크지 않음을 확인하였다. 또한 두 종류 이상의 형광 염료를 사용하여 분석을 하는 경우 발생할 수 있는 형광 신호 간의 간섭 영향을 확인하였다. 간섭의 영향은 Yo-Pro-1의 농도가 높을수록 큰 것으로 확인되었으며 Propidium Iodide의 농도는 형광 신호의 간섭에 큰 영향을 미치지 않음을 확인하였다. 본 연구를 통해 형광 염료의 종류와 농도에 따라 세포 생존율 평가와 전달 효율의 평가 결과가 영향을 받는 것을 확인했으며 이는 형광 염료의 특성과 연관이 있는 것으로 판단된다. 또한, 본 연구 결과를 토대로 세포 생존율 평가와 전달 효율 평가에 적절한 형광 염료의 선정과 사용에 적절한 농도를 제시하였다.

2-beam Coupling 방법을 이용한 광 고분자 형광 패턴 형성 (Fluorescent Pattern Generation on the Fluorescent Photopolymer with 2-beam Coupling Method)

  • 김윤정;김정훈;심보연;이명규;김은경
    • 한국광학회지
    • /
    • 제21권1호
    • /
    • pp.6-11
    • /
    • 2010
  • 아크릴레이트계 모노머를 사용한 최적화 된 포토폴리머에 안트라센 형광폴리머를 첨가하여 형광 특성을 가지는 포토폴리머를 제조하고, 514 nm 레이저를 이용하여 2-beam coupling 방법으로 형광 포토폴리머 필름 위에 회절격자를 형성하였다. 기록 시작 후 30초 이내에 선명한 fluorescent line pattern 이 형성되었으며, 회절격자 형성 뒤, 패턴이 형성된 부분에서 형광 세기의 증가가 관찰되었다. 기록 시 간섭 빔 앞에 mask pattern 을 이용하여 $50\;{\mu}m$ gap electrode 패턴을 형성하였다. 이 때 형성된 패턴은 micron scale gap패턴 안에 회절격자로부터 생성된 submicron scale의 grating line을 보였다. 이는 beam의 광 고분자 film 표면에 대한 각도($3.6^{\circ}$, $15^{\circ}$), 패턴에 사용된 광 고분자의 굴절률 등으로부터 Bragg's equation 을 사용하여 계산된 이론적인 grating 간격 ($0.6\;{\mu}m$) 과 오차범위 안에서 일치 하였다.

형광 나노입자: 합성 및 응용 (Fluorescent Nanoparticles: Synthesis and Applications)

  • 김영국;송병관;이정구;백연경
    • 한국분말재료학회지
    • /
    • 제27권2호
    • /
    • pp.154-163
    • /
    • 2020
  • Fluorescent nanoparticles are characterized by their unique properties such as luminescence, optical transparency, and sensitivity to various chemical environments. For example, semiconductor nanocrystals (quantum dots), which are nanophosphors doped with transition metal or rare earth ions, can be classified as fluorescent nanoparticles. Tuning their optical and physico-chemical properties can be carried out by considering and taking advantage of nanoscale effects. For instance, quantum confinement causes a much higher fluorescence with nanoparticles than with their bulk counterparts. Recently, various types of fluorescent nanoparticles have been synthesized to extend their applications to other fields. In this study, State-of-the-art fluorescent nanoparticles are reviewed with emphasis on their analytical and anti-counterfeiting applications and synthesis processes. Moreover, the fundamental principles behind the exceptional properties of fluorescent nanoparticles are discussed.