• Title/Summary/Keyword: Flow Mobility

Search Result 270, Processing Time 0.023 seconds

An Electrical Characteristics on the Pentacene-Based Organic Thin-Film Transistors using PVA Alignment Layer (PVA 배열층을 이용한 펜타신 유기 박막 트랜지스터의 전기적 특성)

  • Jun, Hyeon-Sung;Oh, Hwan-Sool
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.177-182
    • /
    • 2010
  • The pentacene-based organic thin film transistors(OTFTs) using polyvinylalcohol(PVA) alignment layer were fabricated on the $SiO_2$ evaporated to n-type (111) Si substrates. The pentacene film was deposited by thermally evaporated at $10^{-7}$ torr. X-ray diffraction (XRD) and atomic force microscope(AFM) measurement showed pentacene film which deposited on rubbed PVA layers were partially crystallized at (001) plane. The pentacene OTFTs with PVA layers rubbed perpendicular to the direction of current flow was shown to align better orientation than parallel rubbed case and thus to enhance the mobility and saturation current by a factor of 2.3 respectively. We obtained mobility by 0.026 $cm^2$/Vs and on-off current ratio by ${\sim}10^8$.

Evaluation of Electrokinetic Flow Mobility Using Isotacho-Electrophoresis Techniques

  • An, J.H.;Joo, Y.H.;Lee, C.Y.;Lee, Y.J.;Park, C.W.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.444-448
    • /
    • 2011
  • In the present study, we separated the marker particles from the suspending particle mixture solution using isotacho-electrophoresis technique, a novel quantitative ionic particle separation method, in the microchannel. A multiple stacking zone of the suspending particle was visualized with variations in electric field strength, pH value and concentration of the ionic solution. In particular, the electrophoretic mobility of ionic particle (fluorescein) was estimated based on the electrophoretic velocity value measured by the particle image velocimetry. As a result, isotacho-electrophoresis zones were clearly visualized as going downstream in the electric field. The particle migration velocity increased proportional to the applied voltage increase; it was also affected by the pH value variations in the ionic solution.

A Study on the Relationship between Oxygen and Carrier Concentration in a GZO Film on an Amorphous Structure (GZO 박막에 대한 비정질 구조에 따른 산소공공과 전하농도의 연관성에 대한 연구)

  • Kim, Do Hyoung;Kim, Hong Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.25-29
    • /
    • 2015
  • In this study, RF magnetron sputtering was used to investigate the relationship between oxygen vacancy and carrier concentration in a GZO film on an amorphous structure. RF power was fixed at 50W and Ar flow was changed on a glass plate to create a thin film at room temperature. The transmittance of Al-adopted amorphous GZO was measured at 85% or higher; therefore, the transmittance was shown to be outstanding in all films. The hall mobility was also shown to be higher at the film showing the high transmittance at a short-wavelength, whereas the optical energy gap was shown to be higher at the film with high oxygen vacancy. The oxygen vacancy at the amorphous oxide semi-conductor increased the optical energy gap while it was not directly involved in increasing the mobility. The oxygen vacancy increases the carrier concentration while lowering the quality of amorphous structure; such factor, therefore affected the mobility. The increase of amorphous property is a direct way to increase the mobility of amorphous oxide semi-conductor.

Effect of Flow Rate on the Continuous Cycling Electrolytic Treatment Process for Silver Ion Containing Wastewater (은 함유 폐수의 연속 순환 전해처리 시 유량변화가 회수 공정에 미치는 영향)

  • Chung, Won-Ju;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.577-580
    • /
    • 2007
  • The influence of flow rate has been investigated on the treatment efficiency of continuous cycling electrolytic process employing artificial and actual photographic wastewater which containing silver ion. For artificial wastewater, the treatment efficiency of process was found to rise ca. three times when the flow rate of wastewater was increased from 3 mL/min to 15 mL/min. The process efficiency was doubled under the same condition regarding actual wastewater. The effect of flow rate on the treatment efficiency was observed to be altered according to the metal ionic form and solution composition. The coefficient of mass transfer was estimated using model equation, which verified that the raised treatment efficiency at higher flow rate was due to the increased mobility of ionic species.

A Study on Ammonia Partial Oxidation over Ru Catalyst (Ru 촉매에서의 암모니아 부분산화에 대한 연구)

  • SANGHO LEE;HYEONGJUN JANG;CHEOLWOONG PARK;SECHUL OH;SUNYOUP LEE;YONGRAE KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.786-794
    • /
    • 2022
  • Green ammonia is a promising renewable energy carrier. Green ammonia can be used in various energy conversion devices (e.g., engine, fuel cell, etc.). Ammonia has to be fed with hydrogen for start-up and failure protection of some energy conversion devices. Ammonia can be converted into hydrogen by decomposition and partial oxidation. Especially, partial oxidation has the advantages of fast start-up, thermally self-sustaining operation and compact size. In this paper, thermodynamics, start-up and operation characteristics of ammonia partial oxidation were investigated. O2/NH3 ratio, ammonia flow rate and catalyst volume were varied as operation parameters. In thermodynamic analysis, ammonia conversion was maximized in the O2/NH3 range from 0.10 to 0.15. Ammonia partial oxidation reactor was successfully started using 12 V glow plug. At 0.13 of O2/HN3 ratio and 10 LPM of ammonia flow rate, ammonia partial oxidation reactor showed 90% of ammonia conversion over commercial Ru catalyst. In addition, Increasing O2/NH3 ratio from 0.10 to 0.13 was more effective for high ammonia conversion than increasing catalyst volume at 0.10 of O2/NH3.

Preparation of ITO Thin Films for Display Application with $O_2$ Gas Flow Ratio and Input Current by FTS (Facing Targets Sputtering) System

  • Kim, H.W.;Keum, M.J.;Lee, K.S.;Kim, H.K.;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1477-1479
    • /
    • 2005
  • In this work, the ITO thin films were prepared by FTS (Facing Targets Sputtering) system under different sputtering conditions which were varying $O_2$ gas flow, input current at room temperature. As a function of sputtering conditions, electrical and optical properties of prepared ITO thin films were measured. The electrical, optical characteristics and surface roughness of prepared ITO thin films were measured. In the results, as increasing $O_2$ gas 0.1[sccm] to 0.7[sccm], resistivity of ITO thin film was increased with a decreasing carrier concentration, $O_2$ gas over 0.3[sccm] the carrier mobility have a similarly value. Transmittance of prepared ITO thin films were improved at increasing $O_2$ gas 0.1[sccm] to 0.7[sccm]. And transmittance of all of the prepared ITO thin films was over 80%. We could obtain resistivity $6.19{\times}10^{-4}[{\omega}{\cdot}cm]$, carrier mobility $22.9[cm^2/V{\cdot}sec]$, carrier concentration $4.41{\times}10^{20}[cm^{-3}]$ and transmittance over 80% of ITO thin film prepared at working pressure 1mTorr, input current 0.4A without any substrate heating.

  • PDF

Experimental Study On Power Flow Analysis of Vibration of a Coupled Plate (연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Lee, G.H.;Kil, H.G.;Hwang, S.G.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency responsefunctionshasbeenperformed.

  • PDF

Brownian Dynamics Simulation Study on the Anisotropic FENE Dumbbell Model for Concentrated Polymer Solution and the Melt

  • Sim, Hun Gu;Lee, Chang Jun;Kim, Un Jeon;Bae, Hyeong Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.9
    • /
    • pp.875-881
    • /
    • 2000
  • We study the rheological properties of concentrated polymer solution and the melt under simple shear and elon-gational flow using Brownian dynamicssimulation. In order to describe the anisotropic molecular motion, we modifiedthe Giesekus' mobility tensor by incorporating the finitely extensible non-linear elastic (FENE) spring force into dumbbell model. To elucidate the nature of this model, our simulation results are compared with the data of FENE-P ("P"standsfor the Perterin) dumbbell model and experiments. While in steady state both original FENE and FENE-P models exhibit a similar viscosity response,the growthof viscosity becomes dissimilar as the anisotropy decreases and the flowrate increases. The steady state viscosity obtained from the simulation well describes the experiments including the shear-thinning behavior in shear flow and viscosity-thinning behavior in elongational flow. But the growth of viscosity oforiginal FENE dumbbell model cannot describe the experimental results in both flow fields.