• Title/Summary/Keyword: FlipMin

Search Result 110, Processing Time 0.023 seconds

A Compact Low-Power Shunt Proximity Touch Sensor and Readout for Haptic Function

  • Lee, Yong-Min;Lee, Kye-Shin;Jeong, Taikyeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.380-386
    • /
    • 2016
  • This paper presents a compact and low-power on-chip touch sensor and readout circuit using shunt proximity touch sensor and its design scheme. In the proposed touch sensor readout circuit, the touch panel condition depending on the proximity of the finger is directly converted into the corresponding voltage level without additional signal conditioning procedures. Furthermore, the additional circuitry including the comparator and the flip-flop does not consume any static current, which leads to a low-power design scheme. A new prototype touch sensor readout integrated circuit was fabricated using complementally metal oxide silicon (CMOS) $0.18{\mu}m$ technology with core area of $0.032mm^2$ and total current of $125{\mu}A$. Our measurement result shows that an actual 10.4 inches capacitive type touch screen panel (TSP) can detect the finger size from 0 to 1.52 mm, sharply.

Optical Failure Analysis Technique in Deep Submicron CMOS Integrated Circuits

  • Kim, Sunk-Won;Lee, Hyong-Min;Lee, Hyun-Joong;Woo, Jong-Kwan;Cheon, Jun-Ho;Kim, Hwan-Yong;Park, Young-June;Kim, Su-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.4
    • /
    • pp.302-308
    • /
    • 2011
  • In this paper, we have proposed a new approach for optical failure analysis which employs a CMOS photon-emitting circuitry, consisting of a flip-flop based on a sense amplifier and a photon-emitting device. This method can be used even with deep-submicron processes where conventional optical failure analyses are difficult to use due to the low sensitivity in the near infrared (NIR) region of the spectrum. The effectiveness of our approach has been proved by the failure analysis of a prototype designed and fabricated in 0.18 ${\mu}m$ CMOS process.

Recent Advances in Radiation-Hardened Sensor Readout Integrated Circuits

  • Um, Minseong;Ro, Duckhoon;Kang, Myounggon;Chang, Ik Joon;Lee, Hyung-Min
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.3
    • /
    • pp.81-87
    • /
    • 2020
  • An instrumentation amplifier (IA) and an analog-to-digital converter (ADC) are essential circuit blocks for accurate and robust sensor readout systems. This paper introduces recent advances in radiation-hardening by design (RHBD) techniques applied for the sensor readout integrated circuits (IC), e.g., the three-op-amp IA and the successive-approximation register (SAR) ADC, operating against total ionizing dose (TID) and singe event effect (SEE) in harsh radiation environments. The radiation-hardened IA utilized TID monitoring and adaptive reference control to compensate for transistor parameter variations due to radiation effects. The radiation-hardened SAR ADC adopts delay-based double-feedback flip-flops to prevent soft errors which flips the data bits. Radiation-hardened IA and ADC were verified through compact model simulation, and fabricated CMOS chips were measured in radiation facilities to confirm their radiation tolerance.

Formation of fine pitch solder bump with high uniformity by the tilted electrode ring (경사진 전극링을 이용한 고균일도의 미세 솔더범프 형성)

  • Ju, Chul-Won;Lee, Kyung-Ho;Min, Byoung-Gue;Kim, Seong-Il;Lee, Jong-Min;Kang, Young-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.323-327
    • /
    • 2004
  • The bubble flow from the wafer surface during plating process was studied in this paper. The plating shape in the opening of photoresist becomes gradated shape in the fountain plating system, because bubbles from the wafer surface are difficult to escape from the deep openings, vias. So, we designed the tilted electrode ring contact to get uniform bump height on all over the wafer and evaluated the film uniformity by SEM and ${\alpha}-step$. In ${\alpha}-step$ measurement, film uniformities in the fountain plating system and the tilted electrode ring contact system were ${\pm}16.6%,\;{\pm}4%$ respectively.

  • PDF

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Dynamics of a Bose-Einstein Condensate on Changing Speeds of an Atomchip Trap Potential

  • Kim, Seung Jin;Noh, Jae June;Kim, Min Seok;Lee, Jin Seung;Yu, Hoon;Kim, Jung Bog
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.633-638
    • /
    • 2014
  • We report experimental behaviors of condensed $^{87}Rb$ atoms responding to changes in the trap potential of the atomchip. The two-types of adiabatic and non-adiabatic overall changes were implemented by changing the ramp-down speed of the chip-wire current, which can dominantly modify the one-axis magnetic field gradient. Under the adiabatic process, a pure condensate stayed in the initial spin state and collectively oscillated with both monopole and dipole modes, while an atomic cloud above the critical temperature exhibited sound waves in a dense ultracold gas. On the other hand, Bose-Einstein condensate atoms with non-adiabatic perturbation were split into spatially different positions by spin states through spin-flip. We investigated the split ratio among spin states depending on final evaporation frequency. Potential changes, of course, cause collective oscillations regardless of the changing process.

An Preliminary Technical Analysis of Developing Micro Bump Inspection System (초미세 범프 측정 시스템 개발을 위한 사전 기술 분석)

  • Yoo, Sunggeun;Song, Min-jeong;Park, Sangil;Cho, Sung-man;Jeon, So-yeon;Jeon, Ji-hye;Kim, Hee-tae;Myung, Chan-gyu;Park, Goo-man
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.11a
    • /
    • pp.144-145
    • /
    • 2017
  • 최근 전자 기기의 크기가 줄어들고 PCB의 사이즈와 반도체 패키지의 크기가 소형화되어 플립 칩 본딩(Flip chip bonding) 기술을 적용한 반도체 패키지 방식이 점점 늘어나고 있다. 이에 따라 PCB와 반도체 칩 사이를 연결하기 위해 응용되던 BGA(Ball Grid Array)에 핀 배열 대신 사용되는 범프(Bump)를 50um 이내의 초미세 범프로 만들어 일정한 배열을 유지하는 것이 중요하다. 또한 초미세 범프의 모양과 품질이 패키지 수율과 밀접하게 연관되기 때문에 이를 검사할 수 있는 기술이 필수적이다. 이에 본 논문은 초미세 범프측정을 할 수 있는 시스템 개발을 위한 측정 대상의 특징과 사용할 수 있는 광학계를 분석하였고, 획득된 영상을 가지고 딥러닝을 적용하여 정확하게 불량여부를 판별할 수 있는 초미세 범프 측정 시스템을 고안하였다.

  • PDF

Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency

  • Choi, Narae;Kim, Min-Oh;Shin, Jaewook;Lee, Joonsung;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2016
  • Visualization of the tissue loss tangent property can provide distinct contrast and offer new information related to tissue electrical properties. A method for non-invasive imaging of the electrical loss tangent of tissue using magnetic resonance imaging (MRI) was demonstrated, and the effect of loss tangent was observed through simulations assuming a hyperthermia procedure. For measurement of tissue loss tangent, radiofrequency field maps ($B_1{^+}$ complex map) were acquired using a double-angle actual flip angle imaging MRI sequence. The conductivity and permittivity were estimated from the complex valued $B_1{^+}$ map using Helmholtz equations. Phantom and ex-vivo experiments were then performed. Electromagnetic simulations of hyperthermia were carried out for observation of temperature elevation with respect to loss tangent. Non-invasive imaging of tissue loss tangent via complex valued $B_1{^+}$ mapping using MRI was successfully conducted. Simulation results indicated that loss tangent is a dominant factor in temperature elevation in the high frequency range during hyperthermia. Knowledge of the tissue loss tangent value can be a useful marker for thermotherapy applications.

The Wetting Properties of UBM-coated Si-wafer to the Lead-free Solders in Si-wafer/Bumps/Glass Flip-Chip Bonding System

  • Hong, Soon-Min;Park, Jae-Yong;Park, Chang-Bae;Jung, Jae-Pil;Kang, Choon-Sik
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.74-79
    • /
    • 2000
  • In an attempt to estimate the wetting properties of wettable metal layers by wetting balance method, an analysis of wetting curves of the coating layer was performed. Based on the analysis, wetting properties of UBM-coated Si-plate were estimated by the new wettability indices. The wetting curves of the one and both sides-coated UBM layers have the similar shape and show the similar tendency to the temperature. So the wetting property estimation of one side coating is possible with wetting balance method. For UBM of Si-chip, Cr/Cu/Au UBM is better than Ti/Ni/Au in the point of wetting time. At general reflow temperature, the wettability of high melting point solders(Sn-Sb, Sn-Ag) is better than that of few melting point ones(Sn-Bi, Sn-In).The contact angle of the one side coated plate to the solder can be calculated from the farce balance equation by measuring the static state force and the tilt angle.

  • PDF

VLSI design of efficient VLC/VLD utilizing the characteristics of MPEG DCT coefficients (MPEG DCT 계수의 특징을 이용한 효율적인 VLC/VLD의 VLSI 설계)

  • Kong, Jong-Pil;Kim, Young-Min
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.1
    • /
    • pp.79-86
    • /
    • 1996
  • In this paper we propose an architecture for VLC(Variable Length Coder) and VLD(Variable Length Decoder) which is simple with respect to implementation point and efficient in memory. We implemented encoding and decoding circuit where we need only 7-bit address memory space for 114 MPEG1 DCT coefficients and employed minimal number of flip-flops and logics for an architecture to integrate a shift register for serial-to-parallel or parallel-to-serial conversion of the data in code mapping ROM. We obtained 50Mbps operating speed in both encoding and decoding process as the result of simulation using 0.80.8${\mu}m$ CMOS standard cells.

  • PDF