• Title/Summary/Keyword: Fire water

Search Result 1,101, Processing Time 0.023 seconds

A Survey on the Actual Wearing Conditions of Fire Fighter's Uniform (한국 소방복의 착용만족도 및 착용자 의견에 관한 조사연구)

  • 정정숙;이연순
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.11
    • /
    • pp.75-83
    • /
    • 1999
  • To develope an efficient fire fighter’s uniform for the fire fighting work and body protection, this study examined the regulations of fire lighter’s uniform and surveyed the actual wearing conditions, satisfaction degree, preferred color and design others. The results are as follows; 1. As for the satisfaction degree, the degree was normal in ordinary, low in working uniform and heat-proof uniform and very low in water-proof uniform about its design, size, color and materials. 2. As for the color, red was preferred for the working uniform and water-proof uniform. Blue, yellow and green was preferred next for corking uniform and yellow and blue for water-proof uniform. 3. As for the design, fire fighters wanted partial revision of the present uniform. They preferred stretchy training wear style and overact style in order. For the water-proof uniform, they preferred hip-length suit and pants and next to it they liked flee-length suit, waist belt and overact in order. 4. As for the regulations of the uniform, they wanted some addition in casual uniform, water-proof pants and water-proof gloves, and some deletion in the thermal barrier of water-proof uniform and ordinary uniform. 5. As for the distribution of the uniforms, the use of coupons was highly preferred.

  • PDF

A Study on the Application of Water Mist Fire Extinguishing System to Machinery Spaces (미분무수 소화설비의 선박용 기관실 적용에 관한 연구)

  • Kim, Ki-Ok;Ann, Byung-Ho;Yang, Woo-Jin;Kim, Young-Han
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.132-133
    • /
    • 2005
  • A study to evaluate the fire extinguishing performance of the water mist system inside simulated machinery spaces according to IMO MSC/Circ.668 was performed. Fire tests were conducted inside a compartment having a area 100$m^2$(10m${\times}$10m) with a ceiling height of 10m and door opening of 2m${\times}$2m in size. Test fuels were used heptane, diesel, wood crib and mineral oil. Water mist nozzles were installed downward at ceiling and horizontally at bilge area. All fires in the test were extinguished within 15minutes of system activation and there was no reignition or fire spread.

  • PDF

A Study on Smoke Movement Characteristics for Water spray system Installation in Tunnel (터널내 수분무 시설 설치시 연기유동 특성 연구)

  • Lim, Kyung-Bum;Kim, Ha-Young;Yoo, Ji-Oh;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.230-233
    • /
    • 2008
  • In this study, we conducted an FDS simulation for the purpose of carrying out a basic assessment of the usefulness of the water spray for fire extinguishing. We analyzed the effect of securing the stability in temperature and smoke density in case of fire according to fire intensities and changes in wind speed. When there was no wind speed in tunnels, it was effective in securing the safety of people because the cooling effect of the water spray system had an excellent effect on reducing temperatures and smoke densities there.

  • PDF

EXPERIMENTS ON THE INTERACTION OF WATER SPRAYS WITH POOL FIRES

  • Han, Yong-Shik;Kim, Myung-Bae;Shin, Hyun-Dong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.518-525
    • /
    • 1997
  • A series of measurements and visualization to investigate the interaction of water sprays with pool fires is presented. Fire source is a small-scale pool burner with methanol, ethanol and gasoline. Measurements of temperatures, $O_2$, $CO_2$, and CO concentrations along the plume centerline are carried out to observe pool fire structures without water sprays. Visualization by the Ar-ion laser sheet shows flow pattern of droplets of the sprays above the pool fires. It is observed that in the case of methanol and ethanol, water sprays continuously penetrate into the center of fuel surfaces. The gasoline pool fire allows intermittent penetration of water sprays because of pulsating characteristics of the gasoline flame. To evaluate the cooling effect of the fuel surface by the sprays, the temperature was measured at the fuel surface. As soon as the mists reach the fuel surface of methanol and ethanol, the temperatures of the fuel surface decrease rapidly below the boiling point, and then the fires are extinguished. Due to the application of mist upon the gasoline fire, though the fuel temperature decrease abruptly at the time of the injection, such a rapid decrease do not continue till the extinction point.

  • PDF

Experiments of Water Mist System Application for Rack Storage (랙크식 창고에 대한 미분무 시스템 적용성 실험)

  • Myoung, Sang-Yup;Kim, Jong-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.627-637
    • /
    • 2020
  • Purpose: This experimental study was conducted to find out whether a water-mist fire suppression system can be applied to C.E.P., a representative combustible material of a rack storage. Method: First, it was confirmed whether the water-mist fire-extinguishing system used in this experiment was capable of extinguishing oil fires. After that, the C.E.P. boxes were loaded in the same small space as used in the oil fire experiment, and then the experiment was conducted on three scenarios; door opening, door closing, and door closing and increasing the internal load. The scenario was set considering the opening and space size conditions, which are important factors for the water-mist fire suppression. Result: Oil fire suppression tests have shown that fires are well extinguished in both the door open and closed conditions. In case of a fire of C.E.P. boxes in the same space condition as an oil fire, the fire was not extinguished in the door open condition. Fires were extinguished in the case with the door closed condition, but the afterglow was confirmed. Conclusion: In the oil fire suppression test, a water-mist fire suppression system extinguished a fire in both the door open and closed conditions. However, for the C.E.P fire, it was possible to extinguish only under the door closed condition, and there was a possibility of re-ignition.

Trends of Onboard Fire Extinguishing System (선박용 소화설비의 국제동향)

  • Kim, Mann-Eung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

A Numerical Study on the Fire Suppression Characteristics of a Water Mist with Natural Wind in a Road Tunnel (도로터널에서 자연풍에 의한 미세물분무의 화재제어 특성에 관한 수치해석 연구)

  • Hwang, Cheol-Hong;Kim, Han-Su;Lee, Chang-Eon;Jang, Young-Nam;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.221-227
    • /
    • 2008
  • In this study, the fire suppression characteristics of a water mist with natural wind in a road tunnel were calculated using the FDS(Fire Dynamic Simulation) code. In addition, the cooling and the chemical kinetic effects of water vapor on fire extinction ere investigated in a counterflow non-premixed flame using a detailed chemistry. As a result, the behavior of fire plume and the spray characteristics of water mist are modified remarkably with the increasing of wind velocity. In the case which is not the external natural wind, small droplets are more efficient in fire suppression than large droplets. However, the large droplets show better results on the fire suppression than the small droplets with the increasing of wind velocity. It can be estimated that the natural wind disturb the penetration of water droplets into the flame region and decrease the effect of oxygen dilution. Finally, it can be identified that the fire into the natural wind can be suppressed with smaller amount of $H_2O$ by flame stretching effect in the flame region than one in an enclosure, and the chemical kinetic effects of $H_2O$ on fire extinction are not affected significantly the velocity of natural wind.

A Literature Study on the Combination of acupoints of HANGYEOK and YEOLGYEOK in the Saam Acupuncture Method (사암침법 한격과 열격의 경혈구성에 관한 고찰)

  • Yu, Jun-Sang;Han, Suzy;Yun, Dong Won
    • The Journal of Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.81-97
    • /
    • 2020
  • Objectives: The objective of this study is to review the methods of combining acupoints of HANGYEOK(Cooling Mode) and YEOLGYEOK(Heating Mode) in Saam Acupuncture Method. Methods: We searched and investigated the journals and literatures by OASIS(Korea Institute of Oriental Medicine) and relevant searching engines with the key word "Saam, Hangyeok, Yeolgyeok". Unfortunately there was no relevant articles on this theme except six literatures. Six literatures with the key words relevant to Saam and acupuncture were selected and analyzed according to each composition of acupuncture prescription especially focusing on HANGYEOK and YEOLGYEOK. Results: Analyzing HANGYEOK and YEOLGYEOK of 12 meridians, two different methods emerged. In HANGYEOK to treat Heat Pattern, one method is to tonify Water points and directly sedate Fire points. The other is also to tonify Water point, but sedate Earth points instead of Fire points. It is assumed that Earth sedation method is to eradicate the underlying Fire. In only Heart meridian and Pericardium meridian there is one method to treat Heat Pattern: Water tonification and Fire Sedation. In YEOLGYEOK to treat Cold Pattern, there is one method to tonify Fire points and sedate Water points. In Pericardium meridian and Triple Energizer meridian there are some different combination of acupoints depending on literatures. Conclusions: Considering HANGYEOK and YEOLGYEOK in Saam Acupuncture Method, two methods are mainly discussed in HANGYEOK; Water Tonification Fire Sedation and Water Tonification Earth Sedation. To remove the underlying Fire, it is regarded that Water Tonification Earth Sedation is appropriate and close to Saam's thought.

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.