화재용 중저압 물분무 노즐의 분무특성에 관한 연구 (A Study on Spray Characteristics of Water Mist Nozzle with Mid-low Pressure for Fire Suppression)

  • 김성찬;유홍선;박현태;방기영
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.28-32
    • /
    • 2003
  • The present study investigates the spray characteristics of water mist nozzle with mid-low pressure for fire suppression. The examined nozzle types are swirl and spiral nozzle. The result shows that K factor of water mist nozzle is much smaller than those of general sprinkler. Spray angle of spiral nozzle is largest and more than $150^{\circ}$. SMD(Sauter Mean Diameter) of water mist nozzles is ranged between 100 and 200$\mu\textrm{m}$through measuring by image processing method. The spray pattern of spiral nozzle represent that water flux of first stream is 2 times larger than that of second stream. This study will contribute better understandings of the water-mist spray characteristics and useful daia for developing the water-mist nozzles.

변압기실 화재에 대한 미분무수 소화시스템의 적용 - 소화특성을 중심으로(Part 1) (Application of Water Mist System for a Power Transformer Room - Fire Extinguishment(Part 1))

  • 한용식;최병일;김명배
    • 한국화재소방학회논문지
    • /
    • 제19권4호
    • /
    • pp.32-36
    • /
    • 2005
  • 고전력 변압기에 설치되어있는 가스계 소화설비는 초기 화재에는 대응할 수 있지만 소화후 다시 발화되는 화재에 대하여는 아무런 대책이 될 수 없다. 따라서 초기 소화와 재발화된 화재의 소화 또는 재발화 방지가 가능한 소화 및 냉각시스템이 변압기에 필요할 것이다. 이러한 시스템으로 미분무수 설비가 선택되었으며, 본 연구에서는 주로 소화특성에 대하여 기술한다. 시험 대상으로 특정한 고압과 저압시스템을 선정하여 그 소화능력을 비교하였다. 변압기실은 약 $10m\times10m\times$의 공간이며 변압기의 크기는 이 공간의 $7\%$정도이다. 실물규모의 소화실험이 6개의 화재시나리오 (2개의 분무화재, 3개의 풀 화재, 1개의 흐름화재)에 의하여 수행되었으며, 고압시스템이 저압시스템에 비하여 산소희석 및 냉각효과 측면에서 우수한 소화특성을 나타내었다.

산불현장 지상진화 행동매뉴얼 구축 방안 -국유림관리소 지상진화대원 업무를 중심으로- (Construction Plan of Ground Fire Fighter Conduct Manual on Forest Fire Occurrence Site -Case Study on Ground Fire Fighter Team of National Forest Office-)

  • 이시영;이명욱
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.8-14
    • /
    • 2007
  • 산불현장에서 산불진화 단계에 따라 조치하여야 할 국유림관리소의 개인별 임무 역할 수행내용에 대한 행동매뉴얼 구축방안을 제시하였다. 본 매뉴얼의 적용범위는 (1) 헬기 도착 전에 초기산불 진화에 활용, 2) 헬기 투입 후 지상진화지원 활동에 활용, (3) 헬기 철수 후 뒷불진화에 활용, (4) 헬기진화 불가능한 야간진화에 활용에 두었다. 또한, 본 매뉴얼은 주로 현장진화 지휘자 또는 담당자의 임무를 산불대응 단계에 따라 제1단계인 산불접수단계에서 10단계 철수단계에 이르기까지 총 10단계로 구별하여 정리하였으며, 진화대원들이 평상시 이를 숙지하여 진화대원의 안전은 물론이고 체계적이고 신속한 현장 대응을 통해 산불로부터 인명, 재산피해 및 산림피해를 감소시키는데 기여하고자 개발하였다.

도로터널에서 자연풍에 의한 미세물분무의 화재제어 특성에 관한 수치해석 연구 (A Numerical Study on the Fire Suppression Characteristics of a Water Mist with Natural Wind in a Road Tunnel)

  • 황철홍;김한수;이창언;장영남;신현준
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.221-227
    • /
    • 2008
  • 본 연구에서는 FDS 코드를 이용하여 외부 자연풍에 의한 터널 내의 미세물분무 소화특성을 검토하였으며, 상세반응이 고려된 1차원 대향류 비예혼합화염을 이용하여 화염내부에서 미세물분무의 냉각 및 화학반응효과에 의한 소화현상을 규명하였다. 연구결과로서, 외부 자연풍의 유속 증가에 따라 고온 연기층의 분포 및 분무 특성의 큰 변화가 발생됨을 확인하였다. 외부 자연풍이 없는 경우에는 분무입자 직경이 작을수록 소화성능이 좋지만, 풍속이 증가함에 따라 입자직경이 클수록 소화성능이 좋아짐을 알 수 있었다. 자연풍은 입자의 화염면 침투를 방해할 뿐 아니라. 충분한 산소의 공급으로 화제 억제를 방해할 것으로 예측된다. 또한 자연풍이 존재하는 조건의 화염은 화염 신장효과에 의해 밀폐된 공간에서의 화염 보다 작은 양의 $H_2O$침투에 의해서도 소화될 수 있으며, $H_2O$의 화학반응에 의한 소화효과는 외부 자연풍의 유속에 크게 영향을 받지 않음을 확인하였다.

증점제를 함유한 미분무수의 목재화재 소화효과 (Efficiency of Water Mist Suppression System Containing Viscosity Agent to Extinguish Wood Cribs Fire)

  • 김민형;신창섭
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.78-84
    • /
    • 2014
  • Viscosity agents were added to water to improve extinguishing performance of low pressure water mist suppression system on wood cribs fire, and a small scale wood cribs fire experiment was conducted to measure the extinguishing performance. CMC and agar were used for viscosity agent and as the amount of viscosity agent enlarges, it showed the increase of the viscosity of aqueous solution and the decrease of the fluidity. On wood cribs fire experiment, the extinguishing efficiency was improved with supplemental viscosity agent as it enhanced the adhesive time of aqueous solution on the wood, and therefore expanded the contact time of fire surface. The surface tension of aqueous solution was decreased with the addition of agar which to be assumed as an increase factor of extinguishing efficiency. By the extinguishing experimental result, the most effective extinguishing agent was CMC 0.6 wt.%, with the flame suppression time and the extinguishing time were reduced by 70s and 93s respectively at this concentration.

선박 거주구역용 소화시스템의 전산 시뮬레이션 (COMPUTATIONAL SIMULATION OF FIRE SUPPRESSION SYSTEM FOR CABINS OF SHIPBOARD ENCLOSURE)

  • 정인수;정희택;한용식
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.40-45
    • /
    • 2016
  • The numerical simulation has been performed to predict the performance of the fire suppression system for cabin of shipboard enclosure. The present study aims ultimately at finding the optimal parametric conditions of the mist-injecting nozzles using the CFD methods. The open numerical code was used for the present simulation named as FDS (Fire Dynamics Simulator). Application has been done to predict the interaction between water mist and fire plume. In this study, the passenger cabin was chosen as simulation space. The computational domains for simulation in the passenger cabin were determined following the fire scenario of IMO rules. The full scale of the flow field is $W{\times}L{\times}H=4{\times}3{\times}2.4m^3$ with a dead zone of $W{\times}L{\times}H=1.22{\times}1.1{\times}2.4m^3$. The water mist nozzle is installed in ceiling center of 2.3 m height from the floor, and there are six mattresses and four cushions in the simulation space. The combination patterns of orifices to the main nozzle and the position to install nozzles were chosen as the simulation parameters for design applications. From the present numerical results, the centered-located nozzles having evenly combined orifices were shown as the best performance of fire suppression.

소방·방재 R&D 성과분석 연구 (Performance Analysis for Fire Suppression and Disaster Management R&D Projects)

  • Yoon, Jonghyun;Kim, Geunyoung;Lim, Hyeounjoon
    • 한국재난정보학회 논문집
    • /
    • 제10권2호
    • /
    • pp.208-218
    • /
    • 2014
  • 재난 안전사고에 따른 피해액 증가 및 재난 안전 관련 산업의 성장은 소방방재 R&D 사업에 대한 과학적 성과평가의 필요성을 높여 주고 있다. 2004~2011년 동안의 소방방재 R&D 성과분석 결과에 따르면 성과유형에 있어서 학술적 성과와 공공적 성과가 다수를 이룬다. 그리고 연구수행주체와 연구개발단계별로 성과유형의 특성이 있음을 확인하였다. 이와 같은 결과는 연구수행주체별 성과물의 특성과 연구개발단계별 성과물의 특성을 감안하여 연구과제 선정평가 시 적절한 연구수행 주체와 과학기술분야의 선정과 수행 주체별 성과목표 설정의 적절성을 판단하는데 활용할 수 있을 것으로 보인다. 아울러 성과관리를 위한 기초적인 자료로 활용될 것으로 보인다. 향후 이와 같은 소방 방재 특성을 개선하기 위한 방안을 마련하기 위한 연구를 전문적으로 수행할 필요가 있는 것으로 보인다.

헬기에 의한 지상 물투하 형태 및 범위 실험 (Study on Ground Water Drop Pattern and Coverage Level by Helicopter)

  • 배택훈;이시영;손정훈
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • 항공기에 의한 산불공중진화는 지상진화 보다 진화의 효과성이 좋다. 따라서 공중진화는 산불의 대형화를 방지하는데 중요하다. 미국에서는 고정익항공기 및 회전익항공기(헬리콥터)가 합동으로 공중진화를 하나 우리나라는 회전익항공기만을 이용하고 있다. 따라서 헬리콥터에 의한 공중진화의 효과성에 대한 연구가 필요하다. 공중진화의 효과성은 투하되는 물의 분포형태와 범위에 따라서 결정된다. 따라서 본 연구는 산림청에서 운용하는 S-64E, Ka-32T, AS350B2의 3개 기종으로 물투하 실험을 실시하여 유효 분포형태와 범위를 도출하였다. 이 연구 결과로 조종사들이 공중진화의 효과성을 증대시키는데 기여하고자 한다.

상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구 (A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권4호
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

질소로 희석된 대향류 메탄 비예혼합화염에서 CO2에 의한 소화특성 (CO2 Suppression Characteristics of the Nitrogen-diluted Methane Counterflow Non-premixed Flame)

  • 이호현;오창보;황철홍
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.42-48
    • /
    • 2013
  • The $CO_2$ suppression characteristics and flame structure of nitrogen-diluted methane counterflow non-premixed flame were studied experimentally and numerically. To mimic a situation where combustion product gases are entrained into a compartment fire, fuel stream was diluted with $N_2$. A gas-phase suppression agent, $CO_2$, was diluted in the air-stream to investigate the suppression characteristics by the agent. For numerical simulation, an one-dimensional OPPDIF code was used for comparison with experimental results. An optically-thin radiation model(OTM) was adopted to consider radiation effects on the suppression characteristics. It was confirmed experimentally and numerically that suppression limit decreased with increasing nitrogen mole fraction in the fuel stream. A turning point was found only when a radiation heat loss was considered and the extinguishing concentration for turning point was differently predicted compared to the experiment result. Critical extinguishing concentration when neglecting radiation heat loss was also differently predicted compared with the experimental result.