1 |
2010, Jung I.S., Park, T.K. and Chung, H.T., "Parametric Study on Water Mist Fire Suppression System Based on CFD Methods," (in Korean) J. ILASS-Korea, Vol.15, No.3, pp.12-130.
|
2 |
2008, Maritime Safety Committee, "Amendments to the Revised Guidelines for Approval of Sprinkler Systems Equivalent to that Referred to in SOLAS Regulation II-2/12," IMO Resolution MSC., 265(84).
|
3 |
2000, NIST, "Fire Dynamic Simulator, Technical Reference Guide," NIST, U.S.A.
|
4 |
2007, Bae, K.Y., Chung, H.T. and Kim, H.B., "Numerical Analysis on Interaction between Fire Flame and Water Mist according to the Varaition of Nozzle Performance," (in Korean) Proc. KSME Spring Meetings, pp.2522-2527.
|
5 |
2001, FLUENT Inc., "Fluent 6 User's Guide," FLUENT Inc., U.S.A.
|
6 |
2006, Lee C.H., Chung, H.T., Choi, B.I., Han, Y.S. and Kim, C, "Numeric Study on the Effects of Design Parameters on the Spray Characteristics of Fire Suppression Nozzles," (in Korean) J. ILASS-Korea, Vol.11, No.4, pp.199-204.
|
7 |
2000, Kim, M.B., "A State of the Art for Water Mist Fire Protection Systems and Introduction of NFPA 750," (in Korean) J. Korean Inst. of Fire Science & Eng., Vol.1, No.2, pp.2-5.
|
8 |
2003, Tanner, G. and Knasiak, K.F., "Spray Characterization of Typical Fire Suppression Nozzles," Proc., 3rd Int. Water Mist Conf. Madri, pp.103-109.
|
9 |
2003, Kim, S.C. and Ryou, H.S., "Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire," (in Korean) Proc. KSME Spring Meetings, pp.1703-1708.
|
10 |
2004, Kim, S.C. and Ryou, H.S., "The Effects of Water Mist on the Compartment Fire," Int'l J. Air Conditioning and Refrigeration, Vol.12, No.1, pp.30-36.
|
11 |
2006, Chung, H.T., Lee, C.H., Choi, B.I., Han, Y.S. and Ock, Y.W., "Application of CFD Technique to Prediction of Spray Characteristics of Water-Mist Fire Suppression Nozzles," (in Korean) J. Compt. Fluids Eng., Vol.11, No.4, pp.56-61.
|
12 |
2009, Bae, K.Y., Chung, H.T., Kim, H.B., Jung, I.S. and Kim, C., "Numerical Simulation on Fire Suppression Characteristics through Mobile Mist Spray Nozzles," (in Korean) J. Korean Soc. for Power System Eng., Vol.13, No.5, pp.25-33.
|