• Title/Summary/Keyword: Fire explosion

Search Result 637, Processing Time 0.026 seconds

Experiment and Simulation of Diffusion of Gas Released from the Relief Valve of a Gas Cylinder for a Portable Gas Range (압력 방출밸브를 장착한 이동식 부탄연소기용 부탄캔의 분출가스 확산 실험 및 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • In the last five years, 91 accidents from portable gas ranges and non-refillable metallic gas cartridges have occurred. The gas cylinder installed with a relief valve was developed to prevent an explosive accident from the gas cartridge. In this study it was carried out to evaluate the safety of a gas cylinder mounted with a relief valve which can prevent an explosion. Under the real using condition and the extreme condition the gas cylinder is heated with an electric heater. Simultaneously, the operating pressure is checked and the suitability of releasing flux is evaluated. And the possibility of fire or explosion was tested when the gas was released from the relief valve at the real using condition. Using a numerical simulation method, the diffusion of butane gas released from a relief valve was visualized.

Consequence Analysis of Gas Explosion in LPG Vessel Retail Store Which is Located around Apartment Complex (LPG 판매소에서 가스 폭발이 주위 아파트에 미치는 영향 평가)

  • Lee Su-Kyung;Bae Young-Bum;Oh Jeong-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.48-53
    • /
    • 2006
  • In case of fire and explosion which resulted from LP gas release of LPG vessel retail store, the populated area such as apartment complex is supposed to be damaged either partially or totally. To estimate the damage of LP gas explosion, we conducted quantitative risk analysis procedure as has been recommended by AIChE/CCPS. For incident scenario selection, event tree analysis was proposed. TNT equivalent method, SAFER Trace v.8.0 and probit model were also used for consequence analysis. The various methods and analyses which were performed in this study are presented with the effect zones in the layout.

  • PDF

Measurement and Prediction of Combustion Properties of Styrene (스티렌의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong;Na, Byeong-Gyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.70-76
    • /
    • 2013
  • For the safe handling of styrene, this study was investigated the explosion limits of styrene in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of styrene recommended 0.9 Vol.% and 8.0 Vol.%, respectively. The lower flash points of styrene by using closed-cup tester were experimented $29^{\circ}C{\sim}31^{\circ}C$. The lower flash points of styrene by using open cup tester were experimented $32^{\circ}C{\sim}36^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for styrene. The experimental AIT of styrene was $460^{\circ}C$.

A Research on the Shotcrete Tunnel Application to Concrete mixing PET Fiber (PET FIBER를 혼입한 콘크리트의 숏크리트 터널 적용에 관한 연구)

  • Kim, Joo-Seok;Yoo, Sang-Geon;Lee, Yong-Jun;Shin, Hyum-Seong;Kim, Eun-Kyum
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.928-934
    • /
    • 2008
  • Resently, Fiber Reinforced Concrete is used for not only preventing crack of concrete but also reinforcing general methods. Steel Fiber and PP(poly-propylene) Fiber are usually used as fiber reinforced materials. However, using these materials for shotcrete on Railway tunnel can cause some problems such as damage of pressure hose and shotcrete rebound. In addition, Steel fiber is an expensive material and it can cause safety problems during applying to shotcrete. PP Fiber can cause a problem in fiber balling during applying to shotcrete railway tunnel construction. A purpose of the research is applying a development of PET(Poly Etylene Terephtalate) fiber by recycling pet bottles to the shotcrete tunnel exposed to explosion spalling. To investigate the reinforcement effect of the PET fiber, some basic tests are accomplished to physical properties and explosion spalling by fire. As a result of the tests, a concrete mixing the PET fiber has stronger resistance effect in the explosion spalling by high temperature than another strong fiber concrete does, and that the former concrete is also equal or more effective on the result of the above tests to physical properties like compression and strain than the latter one is demonstrated.

  • PDF

Transient Analysis of Heat Transfer and Pressure Variation for LPG Tank with Metal Explosion Suppression Material (금속폭발억제재가 충진된 LPG 탱크의 비정상 열전달 및 압력변화 해석)

  • Kim H. Y.;Chang H. W.;Chun C. K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.4
    • /
    • pp.406-414
    • /
    • 1987
  • As one of the explosion suppression methods of LPG tank exposed to hot environment by an accident or fire, some material which has large heat capacity and thermal conductivity can be installed inside the LPG tank in order to suppress the temperature increasement of tank wall. In the present study, theoretical model for the horizontally locating cylindrical LPG tank with and without the aluminum explosion suppression material has been developed to predict the characteristics of system. As a parametric study, effects of two major parameters, thickness of material filling and initial vapor volume fraction, on the time variation of wall temperature, temperature and pressure in tank are numerically examined. The results of present study show that the thickness of material filling does not give big differences in the suppression characteristics when the thickness of filling is larger than three inches. In case of material filling, there are marked suppression effects to the increase-ment of wall temperature, average vapor temperature and pressure in tank compared with the case of no filling.

  • PDF

Study on Fire Risk of Air Conditioner through Fire Cases (화재사례를 통한 에어컨의 화재위험성 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.70-77
    • /
    • 2017
  • As the quality of live gets better, the frequency of using air conditioner is along drastically increasing. On that matter, setting up measures of preventing increasing fire cases has been required. 43,413 fire cases occurred in last 2016, the cases occurred by electricity account for about 20%(8,655 cases). Among the electricity cases, the amount of cases occurred with air conditioner issues covers 1.5%; causes of the fire incidents vary, including incomplete contacts, short circuits, tracking, and such. In this study, we intend to investigate the case of ignition at the connection point where the power cord connected to the outdoor unit is arbitrarily connected during the air conditioner installation process, and to propose preventive measures against the cause in order to reduce the damage of life as well as the property from electric fire incidents.

Implications of Emergency Alert and Resident Evacuation in Japan during the Great East Japan Earthquake: Literature Survey Study (동일본 대지진 당시 일본의 비상 발령 및 주민대피에 관한 실태 조사와 시사점 도출: 문헌조사연구)

  • Lee, Jaeyoung;Kim, Younhee;Eom, Young ho
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.500-511
    • /
    • 2021
  • Purpose: This study seeks to draw out implications that must be considered in the process of establishing measures to evacuate residents in preparation for domestic nuclear disasters by conducting an investigation about the disaster situation at the time of the Fukushima nuclear power plant explosion, emergency warning situation for residents protection, evacuation situation and In addition to investigating problems and measures raised in the resident protection system at that time. Method: A literature survey was conducted focusing on reports published by Japan's national, parliament, local governments and related agencies from right after the Great East Japan Earthquake to the present. Result: Found out what needs to be considered in the process of establishing domestic radiation disaster measures through the results of the survey on the problems and countermeasures derived from the process of evacuation of residents at the time of the Fukushima nuclear power plant explosion. Conclusion: The reviews were classified into four categories and detailed reviews were presented.

A Study on Prevention of Fire Accidents by Splash Filling in the Filtration Process of Pharmaceutical Companies (제약회사 여과 공정중 스플래쉬 필링에 의한 화재사고 예방대책에 관한 연구)

  • Kim, Sang Gil;Lee, Dae Joon;Yang, Seung Bok;Rhim, Jong Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.29-34
    • /
    • 2021
  • Flammable substances are often present in the raw materials of pharmaceutical products manufactured by pharmaceutical companies. In this case, an excessive amount of flammable substances is added to make an intermediate, and flammable substances that do not participate in the reaction are removed through filtration and drying steps. In addition, the flammable liquid separated in the filtration process is accumulated in the form of splash filling in the filtrate container. In this case, vapor and mist of flammable liquid are generated, which lowers the lower limit of explosion and minimum ignition energy, and increases the risk of fire and explosion due to complex charging. In this study, by analyzing fire accidents that occurred during the recent filtration process of pharmaceutical companies, it is proposed to prevent static electricity accumulation by measures of nitrogen supply facilities, capacity improvement, conductive filter fabric and so on.

A Study on the Anti-Spalling Performance of High-Strength Concrete Members by covered Engineered Cementitious Composite (ECC로 피복된 고강도콘크리트 부재의 폭렬억제성능에 관한 연구)

  • Lee, Jae-Young;Kim, Jae-Hwan;Han, Byung-Chan;Park, Sun-Gyu;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites (ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 5 HSC specimens are being exposed to fire, in order to exami ne the influence of vari ous parameters (such as depth of layer=20, 30, 40 mm; construction method=lining and repairing type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion (3 hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

Research and Analysis of the Causes and Preventive Measures of Fires Caused by a Disposable Gas Lighter (1회용 가스라이터로 인한 화재 원인과 예방대책의 조사·분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This study analyzed the regulatory actions of disposal gas lighters as well as the situations, causes, and preventive measures of fires, and accidents caused by disposal gas lighters. Since child-resistant lighters became mandatory, the percentage of fires caused by playing with fire has decreased in Korea as it did in America and Japan. Fires caused by disposal gas lighters can occur by afterburning, unintentional lighting, large flames, or explosion or bursting as well as by arson and playing with fire. This study suggests the preventive measures of fires caused by disposal gas lighters as follows: Taking a step not to be used as child's tool for playing with fire, the warning of fire cases caused by afterburning, warning of the dangers of leaving disposal gas lighters on the car dashboard or high temperature places, improving the protective synthetic resin cover of the stop part of a vehicle seat rail, and providing information on precautions for keeping in drawers or disposition methods.