• Title/Summary/Keyword: Fire escape safety

Search Result 118, Processing Time 0.023 seconds

Measurement of the Visibility of the Smoke Images using PCA (PCA를 이용한 연기 영상의 가시도 측정)

  • Yu, Young-Jung;Moon, Sang-ho;Park, Seong-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1474-1480
    • /
    • 2018
  • When fires occur in high-rise buildings, it is difficult to determine whether each escape route is safe because of complex structure. Therefore, it is necessary to provide residents with escape routes quickly after determining their safety. We propose a method to measure the visibility of the escape route due to the smoke generated in the fire by analyzing the images. The visibility can be easily measured if the density of smoke detected in the input image is known. However, this approach is difficult to use because there are no suitable methods for measuring smoke density. In this paper, we use principal component analysis by extracting a background image from input images and making it training data. Background images and smoke images are extracted from images given as inputs, and then the learned principal component analysis is applied to map of as a new feature space, and the change is calculated and the visibility due to the smoke is measured.

A Study on the Safety Regulation Revision for Urban Transit Vehicles (도시철도차량의 안전기준 강화에 관한 연구)

  • Lee Woo-Dong;Shin Jeong-Ryol;Kim Gil-Dong;Han Suk-Youn;Park Kee-Jun;Hong Jai-Sung;Ahn Tai-Ki;Lee Ho-Yong;Kim Jong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.322-326
    • /
    • 2003
  • Dae-gu subway accident raise whole points in connection with safety facilities and operating of national urban transit system like rolling stocks, facilities, management of human. Rolling stock is made every effort for improvement of performance, guarantee of comfortableness, insurance of economical efficiency. But Security like safety of fire is not thoroughgoing enough. Especially, interior material has used although it is not prove its degree of safety. it is a main cause of Dae-gu subway accident. Safety regulation of urban transit vehicle that legislate for security in March 2000 does not applied manufacturing vehicles before in 2000. It has be prescribed in the regulations that incombustibles must be used. But detailed test standard related with incombustibles is not prescribe. Thus that regulation be required reinforcement of detailed test standard. Main cause of Dae-Gu subway accident is a fire in vehicle. However, many defects are found in infrastructure and operating vehicle of urban transit, such as inexperienced disposal of driver and CCC in early stage of the fire accident, unskilled opening and closing doors, insufficient escape facilities and safety facilities of a station house and tunnel, and incomplete communication system between vehicle and CTC, extraordinary step. Thus the aims of this study are prevention of urban transit accident, improvement plan of safety driving, and proposal of quick action plan through analysis of total faculty of vehicle.

  • PDF

A study on quantitative risk assessment for railway Tunnel fire (철도터널에서 차량화재시 정량적 위험도 평가에 관한 연구)

  • Yoo, Ji-Oh;Nam, Chang-Ho;Jo, Hyeong-Je;Kim, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2010
  • As we learned in Daegu subway fire accident, fire in the railway tunnel is prone to develop to large disaster due to the limitation of smoke control and smoke exhaust. In railway tunnel, in order to ensure fire safety, fire prevention and fighting systems are installed by quantitative risk assessment results. Therefore, in this research, developed the program to establish quantitative risk assessment and suggested quantitative safety assessment method including fire scenarios in railway tunnel, fire and evacuation analysis model, fatality estimate model and societal risk criteria. Moreover, this method applys to plan preventing disaster for Honam high speed railway tunnel. As results, we presented the proper distance of escape route and societal risk criteria.

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

How Phenolic Composites were chosen - In Case of England (4) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 4))

  • Nomaguchi, Kanemasa;Forsdyke, Ken L.;Brown, Denver E.
    • Composites Research
    • /
    • v.17 no.4
    • /
    • pp.75-81
    • /
    • 2004
  • In applying phenolic composites in the marine market, Mech-Tool Engineering Ltd. U.K., for instance, they developed, based on their fire approval certificated technologies, many products such as bulkheads for boats, firewalls, blastwalls, blastrelief, escape route or tunnels, small modules, or safety havens and so on. These are one of very best applications with phenolic composites which may inspire you another fire protecting tools of your new products for our societies as well as those products.

Effective Use Of The Evacuation Behavior Of The Crowd In A Fire At The Small Theater (소극장에서 화재시 군중의 피난행동을 이용한 효율적인 대피방법)

  • Shin, Hongkyung;Jeong, Myeongjin;Park, Sojin;Heo, Subin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.249-255
    • /
    • 2019
  • Currently, most small theaters in Korea are not equipped with fire escape prevention laws unlike large theaters. The small theater is a place where many people stay in a small space, which can lead to a great deal of damage in the event of a fire. Therefore, we propose an efficient evacuation method using the evacuation behavior of the crowd as a way to minimize the casualties in case of a fire in a small theater.

A Study on the Analysis of Fire Risk by Fire and the Improvement of Evacuation Equipment for Apartment (About Existing 16 or Fewer Storey Apartment) (공동주택의 화재위험성 분석 및 피난시설 개선에 관한 연구 (16층 이하의 기존 공동주택을 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon;Sa, Jae-Cheon;Nam, Jung-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.127-135
    • /
    • 2011
  • In this study, we assumed the kitchen fire raising the highest fire rate in apt. and analyzed the fire risk to use CFD in order to estimate the problem of evacuation equipment and the fire vulnerability of 16 or fewer storey apartment. Fire occurring in the kitchen is expended to the livingroom and other rooms. We analyzed that the temperature effected by heat was more than $60^{\circ}C$ after 90 sec in the entrance of apartment unit. If fire is early recognized by men and men don't escape in time, it have too huge demage to block the exit. When the evacuation equipment suggested in this study was installed in order to solve the problem of evacuation equipment, we analyzed that it was estimated more than safe in safety evaluation by heat and heat flux.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

Design of Smart Device Assistive Emergency WayFinder Using Vision Based Emergency Exit Sign Detection

  • Lee, Minwoo;Mariappan, Vinayagam;Mfitumukiza, Joseph;Lee, Junghoon;Cho, Juphil;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.101-106
    • /
    • 2017
  • In this paper, we present Emergency exit signs are installed to provide escape routes or ways in buildings like shopping malls, hospitals, industry, and government complex, etc. and various other places for safety purpose to aid people to escape easily during emergency situations. In case of an emergency situation like smoke, fire, bad lightings and crowded stamped condition at emergency situations, it's difficult for people to recognize the emergency exit signs and emergency doors to exit from the emergency building areas. This paper propose an automatic emergency exit sing recognition to find exit direction using a smart device. The proposed approach aims to develop an computer vision based smart phone application to detect emergency exit signs using the smart device camera and guide the direction to escape in the visible and audible output format. In this research, a CAMShift object tracking approach is used to detect the emergency exit sign and the direction information extracted using template matching method. The direction information of the exit sign is stored in a text format and then using text-to-speech the text synthesized to audible acoustic signal. The synthesized acoustic signal render on smart device speaker as an escape guide information to the user. This research result is analyzed and concluded from the views of visual elements selecting, EXIT appearance design and EXIT's placement in the building, which is very valuable and can be commonly referred in wayfinder system.

Study on the Escape Safety of University Dormitory with the Consideration of Plan Types (대학 기숙사의 평면 형태에 따른 피난 안전성 검토)

  • Jeong, Hyeon-Jae;Jeong, Gun-Sik;Ahn, Young-Chull
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • University dormitory has some weaknesses against disaster such as fire because of high population density and strict control of access in night time. The purpose of this study is suggestion of a guide of effective floor plan for improvement of evacuation safety. Plans for preventing disasters are studied and evacuation safeties are analysed using network model analysis method according to plan types. The weakness of disaster prevention is quantified, and effectiveness of bidirectional evacuation is confirmed. The circuit type floor plan shows best evacuation characteristics and this result is anticipated to be adopted to design process of new dormitories and will contribute to improvement of evacuation safety.