Browse > Article

A Study on the Analysis of Fire Risk by Fire and the Improvement of Evacuation Equipment for Apartment (About Existing 16 or Fewer Storey Apartment)  

Min, Se-Hong (경원대학교 공과대학 소방방재공학과)
Lee, Jae-Moon ((주)창우에프이엔씨)
Sa, Jae-Cheon (경원대학교 환경대학원 소방방재공학과)
Nam, Jung-O ((주)크로텍)
Publication Information
Fire Science and Engineering / v.25, no.6, 2011 , pp. 127-135 More about this Journal
Abstract
In this study, we assumed the kitchen fire raising the highest fire rate in apt. and analyzed the fire risk to use CFD in order to estimate the problem of evacuation equipment and the fire vulnerability of 16 or fewer storey apartment. Fire occurring in the kitchen is expended to the livingroom and other rooms. We analyzed that the temperature effected by heat was more than $60^{\circ}C$ after 90 sec in the entrance of apartment unit. If fire is early recognized by men and men don't escape in time, it have too huge demage to block the exit. When the evacuation equipment suggested in this study was installed in order to solve the problem of evacuation equipment, we analyzed that it was estimated more than safe in safety evaluation by heat and heat flux.
Keywords
Analysis of risk by fire; Evacuation equipment; Apartment fire; CFD Modeling;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 소방방재청, "국가화재정보센터 E-화재통계", http:// www.nfds.go.kr/index.jsf.
2 소방방재청 2011년 예방소방행정 통계자료.
3 영등포소방서 화재 구조 구급 상황 보고서(7차보고).
4 중앙일보뉴스 http://article.joinsmsn.com/news/article/ article.asp?total_id=6081476&cloc=olink|article|defa ult.
5 조선일보 뉴스 http://news.chosun.com/site/data/ html_dir/2006/12/14/2006121400008.html.
6 뉴시스 http://news.naver.com/main/read.nhn ?mode= LSD&mid=sec&sid1=102&oid=003&aid=00002603 09.
7 Kevin McGrattan, Simo Hostikka and Jason Floyd, "NIST Special Publication 1019-5 Fire Dynamics Simulator (Version 5)", NIST(2009).
8 Daniel Madrzykowski, NIST Special Publication 1066; Appendix 6.
9 전흥균, "아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구", 한국화재소방학회 논문지,Vol.24, No.4(2010).
10 여용주, "수계소화설비공학", 한국화재연구소, pp.23- 28(2006).
11 소방방재청, "피난기구의 화재안전기준(NFSC 301)", 별표 1 소방대상물의 설치장소별 피난기구의 적응성 (2009).
12 특허청뉴스, "노약자 장애우를 배려한 피난기구 특허 첫걸음", 특허청 http://kipo.korea.kr(2011).