• 제목/요약/키워드: Fire Management

검색결과 1,689건 처리시간 0.034초

반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1) (Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1))

  • 한수진;강경식
    • 대한안전경영과학회지
    • /
    • 제8권5호
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

로지스틱 회귀모형을 이용한 수관화확산확률식의 개발 (Development of Crown Fire Propagation Probability Equation Using Logistic Regression Model)

  • 유계선;이병두;원명수;김경하
    • 한국지리정보학회지
    • /
    • 제17권1호
    • /
    • pp.1-12
    • /
    • 2014
  • 수관화는 대형산불의 주된 확산유형으로 빠른 확산속도와 높은 산불강도의 특성을 보이며 많은 피해를 입힌다. 이 연구에서는 수관화 피해를 사전에 예측하기 위해서 수관전소 피해를 입은 지역의 지형 임상 기상 특성을 분석하여 수관화확산확률식을 개발하였다. 영덕 울진 고령 예천에서 일어난 4개의 산불피해지를 대상으로 하였으며, 총 18개의 공간 변수를 구축한 뒤 기타연소지에 대한 수관전소지의 비를 이용하여 각 변수별 구간 가중치를 구하고 로지스틱 회귀모형을 이용하여 변수와의 상관계수를 산출하였다. 그 결과, 수관화확산확률은 임상이 침엽수림일 때, 250m 이상에서 고도가 높아질수록, 기복이 심할수록, 사면향은 남서 또는 남동사면일 경우, 능선일수록, 일사량이 많아질수록 높게 나타났다. 고도와 경사가 낮은 곳에서는 교란현상이 많이 나타나 일정한 패턴을 보이지 않았다. 이 확률식을 통해 수관화 위험지를 사전에 분석할 수 있고, 산불방지 숲가꾸기 지역 선정 및 진화 우선 지역 선정 등에 효과적으로 활용할 수 있을 것이다.

산불로 인한 지표층 연소량 및 온실가스 배출량 추정 (Estimation of Biomass Loss and Greenhouse Gases Emissions from Surface Layer Burned by Forest Fire)

  • 이병두;윤호중;구교상;김경하
    • 한국산림과학회지
    • /
    • 제101권2호
    • /
    • pp.286-290
    • /
    • 2012
  • 산불은 전 세계적으로 다량의 온실가스를 배출하여 지구온난화에 기여한다. 본 연구에서는 산불로 인한 지표층 연료의 연소량과 이로 인한 온실가스 배출량을 분석하고자 하였다. 이를 위해 51개 산불을 대상으로 소나무림과 활엽수림으로 구분하고, 다시 지표화와 수관화 피해 지역으로 나누어 잔존 연료량을 채취하여, 미연소 지역의 연료량과 일원분산분석을 수행하였다. 그 결과 활엽수 지표화 지역은 8,361 kg/ha, 소나무 지표화 지역은 8,055 kg/ha, 소나무 수관화 지역은 12,333 kg/ha이 연소되어, 수종별 산불행태별로 차이가 있었다. 이때의 연소율은 각각 78, 59, 90%이었다. 이산화탄소, 메탄, 아산화질소 등의 온실가스 배출량은 활엽수 지표화 연소지역 15,856 kg/ha, 소나무 지표화 연소지역 14,834 kg/ha, 소나무 수관화 연소지역은 약 22,709 kg/ha이었다.

소방안전경영시스템 구축을 위한 실태평가에 관한 연구 (A Study on Real Condition Estimation for Fire Protection Safety Management System Builds)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.18-24
    • /
    • 2013
  • 대형화, 다양화되고 있는 화재 폭발사고 및 지구온난화와 자연현상에 의한 재난으로부터 인명과 재산손실을 예방하기 위해 정부와 기업은 많은 노력을 기울이고 있다. 그러나 국가의 성장과 더불어 국민의 삶의 질 향상 및 복지증진이라는 국가의 거시적 목표에 부응하되 기업목적인 이윤추구의 달성을 위해 우선시된 경제정책 속에서 앞만 보고 달려온 기업들은 미온적 위험관리의 결과로 소중한 인명과 재산손실을 감내하고 있다. 2007년 소방방재청의 '안전문화 활성화를 위한 국민안전의식조사'에서 국민이 생각하는 우리 사회의 안전불감증은 '심각한 수준'으로 조사된 바, 본 연구에서는 소방안전사고예방과 안전의식수준향상을 위해 위험관리가 가능한 대기업뿐만 아니라 조직과 예산규모가 작아 사고발생의 위험이 큰 중소기업의 현 실태를 평가, 체계적인 안전관리를 통한 소방안전사고예방을 위해 현 실정에 맞는 '단계별 소방안전경영시스템' 구축에 대한 필요성을 조사하였다.

화재 시 승강기를 이용한 피난에 관한 연구 (A Study on escape using elevators in fire emergency)

  • 정의수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2007년도 추계학술대회
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구 (A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities)

  • 전용한;한상필
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구 (A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS))

  • 민세홍;윤정은
    • 대한안전경영과학회지
    • /
    • 제11권2호
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

인화성액체의 연소 형태에 관한 실험적 연구 (Experimental Studies on the Burning Forms of Flammable Liquids)

  • 최승복;최돈묵
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.247-251
    • /
    • 2010
  • The victims of fire are increasing steadily. Fires have been occurred by arson, spontaneous combustion and various causes. As a result of that, the damages of fire got out of hand. Especially, the fires of flammable liquids are can be spreaded easily because of high calorific value and fire loads. These rapid fire spread cause the huge losses of both life and property and the malfunction of extinguishing systems. In these studies, we examined the spread pattern of surface fire on the water surface by the reappearance experiment.

  • PDF

FIRE PROTECTION FOR PETROCHEMICAL PLANT

  • Suh, Jung-H.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.244-251
    • /
    • 1997
  • Since 1970s, The Petrochemical Industry in Korea has grown rapidly by the successful economic growth. While the process became larger and more complex, hazardous chemicals have been used in large quantity, Therefore, the risk of a major accident such as fire, explosion and toxic material release has been increased. Korea has been ranked the fifth in petrochemical product capacity worldwide, also required to meet international standards on process safety management. Fire Protection System integral part of safely management in Petrochemical Plants, will be reviewed.

  • PDF

전자공장 화재의 다수 사상자 발생원인 분석 (Analysis of the Causes of Multiple Casualties in an Electronics Factory Fire)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.130-139
    • /
    • 2019
  • 2018년 8월 21일 15시 40분경 발생한 전자공장화재로 9명이 사망하고 6명이 부상을 입는 인명피해가 발생하였다. 이 논문에서는 이 전자공장화재에서 다수 사상자가 발생한 원인을 화재조사결과 등을 토대로 구체적으로 분석하고 있다. 다수 사상자가 발생한 주요 원인은 자동화재탐지설비 기능 정지, 비상방송시설 기능 정지, 4층 천장의 우레탄폼 착화로 인한 급격한 화재 확산, 화재발견 직후 정전 발생, 스프링클러설비 미작동, 화재신고 지연, 소방시설관리 업체의 소방시설관리 부실 등으로 분석하였다.