• Title/Summary/Keyword: Field Coverage

Search Result 430, Processing Time 0.025 seconds

Protection of Incumbent Services and Its Impact on Coverage of TV Band Device Networks in TV White Space

  • Kang, Kyu-Min;Park, Jae Cheol;Cho, Sang-In;Park, Seungkeun
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.112-122
    • /
    • 2016
  • This paper presents a set of candidate regulatory requirements for TV band devices (TVBDs) in the Rep. of Korea. To guarantee the protection of incumbent services, especially digital TV (DTV) and wireless microphones, in TV frequency bands, we suggest minimum separation distances of TVBDs from the noise-limited contour according to incumbent users and TVBD types. This paper also deals with multiple sets of separation distances of a co-channel TVBD network from a DTV protected contour on the basis of the radio propagation characteristics of different geographic areas to make good use of TV white space (TVWS) and safely protect the DTV service. We present a low-power transmission mode of TVBDs and the relevant separation distances for small-cell deployment. The service coverage reduction ratio of a TVBD network is investigated in the presence of DTV interference in four geographic areas. The TVWS field verification results, conducted on the island of Jeju (Rep. of Korea), show that incumbent services operate well without harmful interference from neighboring TVBDs with the proposed separation distances.

3D Seismic Travel-time Tomography using Fresnel Volume (프레넬 볼륨을 이용한 3차원 탄성파 주시 토모그래피)

  • Ko, Kwang-Beom;Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.2
    • /
    • pp.101-107
    • /
    • 2003
  • 3D seismic travel-time tomography algorithm baled on Fresnel volume was developed and its feasibility was investigated by the numerical experiments. To testify the field applicability of the developed algorithm, frequency characteristics and way coverage of the crossholel seismic raw data were investigated and 3D velocity tomogram cube with about 8m spatial resolution was obtained. When compared this 3D velocity cube with the conventional 2D ray tomogram, two results were matched well. We concluded that 3D seismic tomography algorithm developed in this study has enough potential to the field application.

Fabrication of Sputtered Gated Silicon Field Emitter Arrays with Low Gate Leakage Currents by Using Si Dry Etch

  • Cho, Eou Sik;Kwon, Sang Jik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.28-31
    • /
    • 2013
  • A volcano shaped gated Si-FEA (silicon field emitter array) was simply fabricated using sputtering as a gate electrode deposition and lift-off for the removal of the oxide mask, respectively. Due to the limited step coverage of well-controlled sputtering and the high aspect ratio in Si dry etch caused by high RF power, it was possible to obtain Si FEAs with a stable volcano shaped gate structure and to realize the restriction of gate leakage current in field emission characteristics. For 100 tip arrays and 625 tip arrays, gate leakage currents were restricted to less than 1% of the anode current in spite of the volcano-shaped gate structure. It was also possible to keep the emitters stable without any failure between the Si cathode and gate electrode in field emission for a long time.

A Field Application of 3D Seismic Traveltime Tomography (I) - Constitution of 3D Seismic Traveltime Tomography Algorithm - (3차원 탄성파 토모그래피의 현장 적용 (1) - 3차원 토모그래피 알고리즘의 구성 -)

  • Moon, Yoon-Sup;Ha, Hee-Sang;Ko, Kwang-Buem;Kim, Ji-Soo
    • Tunnel and Underground Space
    • /
    • v.18 no.3
    • /
    • pp.202-213
    • /
    • 2008
  • In this study, theoretical approach of 3D seismic traveltime tomography was investigated. To guarantee the successful field application of 3D tomography, appropriate control of problem associated with blind zone is pre-requisite. To overcome the velocity distortion of the reconstructed tomogram due to insufficient source-receiver array coverage, the algorithm of 3D seismic traveltime tomography based on the Fresnel volume was developed as a technique of ray-path broadening. For the successful reconstruction of velocity cube, 3D traveltime algorithm was explored and employed on the basis of 2nd order Fast Marching Method(FMM), resulting in improvement of precision and accuracy. To prove the validity and field application of this algorithm, two numerical experiments were performed for globular and layered models. The algorithm was also found to be successfully applicable to field data.

Plan Dose Evaluation of Three Dimensional Conformal Radiotherapy Planning (3D-CRT) of Nasopharyngeal Carcinoma (NPC): Experience of a Tertiary Care University Hospital in Pakistan

  • Abbasi, Ahmed Nadeem;Hafiz, Asim;Ali, Nasir;Khan, Khurshid Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5989-5993
    • /
    • 2013
  • Background: Radiation therapy is the mainstay of treatment for nasopharyngeal carcinoma. Importance of tumor coverage and challenges posed by its unique and critical location are well evident. Therefore we aimed to evaluate our radiation treatment plan through dose volume histograms (DVHs) to find planning target volume (PTV) dose coverage and factors affecting it. Materials and Methods: This retrospective study covered 45 histologically proven nasopharyngeal cancer patients who were treated with definitive 3D-CRT and chemotherapy between Feb 2006 to March 2013 at the Department of Oncology, Section Radiation Oncology, Aga Khan University Hospital, Karachi, Pakistan. DVH was evaluated to find numbers of shrinking field (phases), PTV volume in different phases and its coverage by the 95% isodose lines, along with influencing factors. Results: There were 36 males (80%) and 9 females (20%) in the age range of 12-84 years. Stage IVA (46.7%) was the most common stage followed by stage III (31.1). Eighty six point six-percent received induction, 95.5% received concurrent and 22.2% received adjuvant chemotherapy. The prescribed median radiation dose was 70Gy to primary, 60Gy to clinically positive neck nodes and 50Gy to clinically negative neck regions. Mean dose to spinal cord was 44.2Gy and to optic chiasma was 52Gy. Thirty seven point eight-percent patients completed their treatment in three phases while 62.2% required four to five phases. Mean volume for PTV3 was $247.8cm^3$ (50-644.3), PTV4 $173.8cm^3$ (26.5-345.1) and PTV5 $119.6cm^3$ (18.9-246.1) and PTV volume coverage by 95% isodose lines were 74.4%, 85.7% and 100% respectively. Advanced T stage, intracranial extension and tumor volume > $200cm^3$ were found to be important factors associated with decreased PTV coverage by 95% isodose line. Conclusions: 3D CRT results in adequate PTV dose coverage by 95% isodose line. However advanced T stage, intracranial extension and large target volume require more advanced techniques like IMRT for appropriate PTV coverage.

Epipolar Geometry of Line Cameras Moving with Constant Velocity and Attitude

  • Habib, Ayman F.;Morgan, Michel F.;Jeong, Soo;Kim, Kyung-Ok
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.172-180
    • /
    • 2005
  • Image resampling according to epipolar geometry is an important prerequisite for a variety of photogrammetric tasks. Established procedures for resampling frame images according to epipolar geometry are not suitable for scenes captured by line cameras. In this paper, the mathematical model describing epipolar lines in scenes captured by line cameras moving with constant velocity and attitude is established and analyzed. The choice of this trajectory is motivated by the fact that many line cameras can be assumed to follow such a flight path during the short duration of a scene capture (especially when considering space-borne imaging platforms). Experimental results from synthetic along-track and across-track stereo-scenes are presented. For these scenes, the deviations of the resulting epipolar lines from straightness, as the camera's angular field of view decreases, are quantified and presented.

  • PDF

A Study of Radio Wave Propagation Characteristics at 900MHz Range for Urban Modelling (도시형 모델링을 위한 900MHz대 전파전파 특성에 대한 연구(I))

  • 남채우;박성교박종백
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.165-168
    • /
    • 1998
  • This paper describes the characteristics of CT-2 radio wave propagation at 900MHz range. Typical cell coverage of CT-2 based on picocellular design provides a 200m radius. The five sites of urban regions of Kwang Ju city were chosen to characterize propagation in various environments. On the basis of cell coverage data measured with field strength meter, average 75% of telepoint service was retained and it was lack 25% of overall gain. In some sites telepoint service was limited to two of four directions around a station. If specially designed collinear antenna with specific directivities are used in these shadow area, improved results will be acquired.

  • PDF

A Short Consideration of Binomial Confidence Interval (이항신뢰구간에 대한 소고)

  • Ryu, Jea-Bok
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.5
    • /
    • pp.731-743
    • /
    • 2009
  • The interval estimation for binomial proportion has been treated practically as well as theoretically for a long time. In this paper we compared the properties of major confidence intervals and summarized current issues for coverage probability and interval length which are the criteria of evaluation for confidence interval. Additionally, we examined the three topics which were considered in using the binomial confidence interval in the field. And finally we discussed the future studies for a low binomial proportion.

GPS Implementation for GIS Coverage Map (GPS 측량시스템을 이용한 GIS 커버리지 맵 구현)

  • 임삼성;노현호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.3
    • /
    • pp.197-203
    • /
    • 1999
  • Depending on geographical features and error sources in the survey field, inaccurate data is inevitable in GPS kinematic survey for positioning with feature codes. In this study, the trimmed mean and the first order differential equation are used to develop an inaccurate positioning data detection algorithm, and a cubic spline curve and a linear polynomial are used to interpolate the inaccurate data. Based on interpolated data, a digital map for 30 km range of rural highway is produced and a corresponding GIS coverage map is obtained by analyzing and solving the problem associated with the map.

  • PDF

Analysis of the Medical Market Share of Traditional East Asian Medicine (TEAM) in Taiwan Using National Health Insurance Research Database (NHIRD) (대만 건강보험연구데이터(NHIRD)를 이용한 대만에서의 전통 동아시아 의학(TEAM)의 의료시장 점유율 분석)

  • Jeung, Chang-Woon;Choi, Chang-Hyuk;Jo, Hee-Geun;Song, Min-Yeong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.133-144
    • /
    • 2018
  • Objectives Since the health insurance coverage for traditional Korean medicine is very low, some physicians and researcher have suggested that government's institutional support is needed for korean medicine field. Therefore We examine the use of traditional medicine and western medicine in Taiwan, which operates a similar health insurance system to Korea. Methods We selected several studies from Pubmed and NHIRD, that could be used to numerically evaluate the use of traditional medicine. We reviewed the current status of medical use in Taiwan and compare it with that of Korea. Results Through a total of 87 studies, We found that 26.59%~31% of Taiwanese use Traditional medical institutions more than once a year, and the use of traditional medicine has been increasing since 2000. In adults than children, in women than men, the use rate of traditional medicine was high. Especially, herbal medicine was the most common intervention, accounting for 70% of traditional medical care. Conclusions The core of low insurance coverage for traditional Korean medicine is in lack of coverage for herbal medicine. Taiwan's case shows that the unmet demand for traditional Korean medicine of the Korean population can exist widely.