• Title/Summary/Keyword: Fault analysis

Search Result 2,751, Processing Time 0.03 seconds

The Analysis of Operational Characteristics of Inductive High-Tc Superconducting Fault Current Limiter Concerning Harmonic Component (고조파 성분을 고려한 유도형 고온초전도한류기의 동작 특성 해석)

  • Yim, Do-Hyon;Joo, Min-Seok;Chu, Yong;Kim, Han-Jun;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.131-133
    • /
    • 1995
  • Inductive high-Tc superconducting fault current limiter using YBCO superconducting ring in the secondary part has many advantages in power networks. It is based on the superconducting to normal transition and this paper describes its operational characteristics and experimental results, especially focused on the harmonic component analysis and recovery time. We fabricated and tested it under various conditions for the analysis of transient fault characteristics. And for the analysis of harmonics we used FFT methods. The superconducting ring was quenched in 240Arms and fault current was effectively limited to the lower current level. In addition, it was fast recovered when the fault condition was removed and after fault the system had odd harmonics.

  • PDF

Behavioral Characteristics of the Yangsan Fault based on Geometric Analysis of Fault Slip (단층슬립의 기하분석에 의한 양산단층의 거동 특성)

  • Chang, Chun-Joong;Chang, Tae-Woo
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.277-285
    • /
    • 2009
  • In order to assess the fault behavior by the geometric analysis of fault slip, the study area between Yangsan city and Shinkwang-myon, Pohang city along the strike of the Yangsan fault is divided into 5 domains($A{\sim}E$ domains) based on the strike change of main fault, the type of fault termination, the cyclic variation of fault zone width, deformation pattern of fault rocks and angular deviation of secondary shears. And, we would apply the relationship between the mode of fault sliding and the resultant deformation texture obtained from previous several experimental studies of simulated fault gouge to the study of the Yangsan fault. To understand sliding behavior of the fault we measured the data of fault attitude and fault slip, and analyzed relationships between the main fault and secondary Riedel shear along the Yangsan fault. The sliding behavioral patterns in each section were analyzed as followings; the straight sections of A, D and E domains were analyzed as the creeping section of stably sliding. In contrast, the curved section of B domain was analyzed as the locked section of stick-slip movement.

Differential Fault Attack on SSB Cipher (SSB 암호 알고리즘에 대한 차분 오류 공격)

  • Kang, HyungChul;Lee, Changhoon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.1
    • /
    • pp.48-52
    • /
    • 2015
  • In this paper, we propose a differential fault analysis on SSB having same structure in encryption and decryption proposed in 2011. The target algorithm was designed using advanced encryption standard and has advantage about hardware implementations. The differential fault analysis is one of side channel attacks, combination of the fault injection attacks with the differential cryptanalysis. Because SSB is suitable for hardware, it must be secure for the differential fault analysis. However, using proposed differential fault attack in this paper, we can recover the 128 bit secret key of SSB through only one random byte fault injection and an exhausted search of $2^8$. This is the first cryptanalytic result on SSB having same structure in encryption and decryption.

Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle (무선충전 전기자동차 전력공급장치에서의 지락사고 특성 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Um;Song, Young-Sang;Lim, Hyun-Sung;Cho, Min-Ho;Lyu, Ji-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.13-17
    • /
    • 2014
  • In this paper, the risk of electric shock is analyzed through analysis for characterization of potential distribution analysis and ground fault current analysis near the area where there are occurred a ground fault at electric vehicle wireless charging system using 20kHz. Studies for electric vehicle wireless charging system are in the works for development of efficiency increase, pickup shape design and communication module as a fundamental research step. But the research related to electrical safety and is still scarce state so that more studies are necessary to commercialize. As a result of analysis, it is verified that induced voltage is arisen more up to 45V near the a area of accident during ground fault and fault current has been maintained continuously without clearing fault condition by operating characteristics for circuit breaker and inverter.

A Study of Stability Evaluation for Tunnel at the Fault Zone Crossing (단층대를 통과하는 터널의 안정성확보에 관한 연구)

  • 박인준;최정환;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.105-112
    • /
    • 2001
  • The purpose of this study is to assess the stability of tunnel for a high speed railway crossing the fault zone. The area where the tunnel crossed the fault zone can be unstable during construction and operation. Geotechnical investigations have been conducted to determine an optimum excavation method by obtaining the material properties around the fault zone and to check the stability of the tunnel. For the numerical analysis, the FLAC, numerical analysis code based on finite difference method, was utilized to analyze the behavior of the fault at three points having typical ground conditions. Based on the results of numerical analysis, the combinations of compaction grouting and LW grouting were determined as suitable methods for pre-excavation Improvement of the ground surrounding the tunnel opening. In conclusion, the stability of the tunnel construction for the high speed railway within the fault zone may be obtained by adopting the optimum excavation method and the reinforcement method. The numerical analysis based on FLAC program contains errors caused by assumptions used in numerical analysis, therefore constant monitoring with respect to the change of ground condition and groundwater is highly recommended to minimize the numerical error and the possibility of damage to tunnel.

  • PDF

Integration of Image Regions and Product Components Information to Support Fault (조립체 결함 분석 지원을 위한 영상 영역과 부품 정보의 병합 ^x Integration of Image Regions and Product Components Information to Support Fault)

  • Kim, Sun-Hee;Kim, Kyoung-Yun;Lee, Hyung-Jae;Kwon, Oh-Byung;Yang, Hyung-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.11
    • /
    • pp.266-275
    • /
    • 2006
  • Mostly mechanical products are connected by several components instead of single accessory in product process. Although majority of assembly process is automated, the fault analysis is not automated because it needs expert knowledge in various fields to support inclusive decision-marking. This paper proposes an assembly fault analysis support system that uses image regions which can be easily accessed and understood by experts of various fields. An assembly fault analysis support system helps effective fault analysis from assembly by integrating image regions, product design information, and fault detection information. The proposed method enables fault information access from multimedia information by segmenting product images. After product images are segmented by labeling, design information and fault information are integrated in extended Attributed Relational Graph.

  • PDF

A Methodology for Constructing Function Tree & Fault Tree in Reliability Analysis (신뢰성 분석을 위한 Function Tree 및 Fault Tree 구성 방법에 관한 연구)

  • Ha, Sung-Do;Lee, Eon-Kyung;Kang, Dal-Mo
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.333-338
    • /
    • 2001
  • Fault tree is a widely used methodology for analyzing product reliability. The fault trees are usually constructed using the experiences of expert reliability engineers in top-down approaches and have different structures according to each expert's subjectivity. In this work it is tried to find a general method for the fault tree construction based on the function tree that is the result of product function deployment. Based on the function tree, the method has the advantage of resulting an objective fault tree since the faults are defined as the opposite concept of functions. The fault tree construction of this work consists of the following steps: 1) definition of product primary function with the viewpoints of product operation and configuration, 2) construction of functional relation chart using a grouping algorithm, 3) abstraction of functional block diagram according to operation sequences and configuration of a product, 4) construction of function tree for each viewpoint, and 5) construction of fault tree by matching the function tree and simplification of the result.

  • PDF

Dynamic Analysis Algorithm of Irreversible Demagnetization of IPM-type Brushless DC Motor by Stator Turn Fault (고정자 절연파괴 고장에 의한 매입형 영구자석 BLDC 모터의 불가역 감자에 대한 동적해석 알고리즘)

  • Lee, Yoon-Seok;Kim, Kyung-Tae;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1661-1667
    • /
    • 2013
  • This paper studies the dynamic irreversible demagnetization characteristics of an interior permanent magnet (PM) brushless DC motor with a stator turn fault. A new algorithm, which is a finite element method (FEM) combined with a line voltage equation of the motor, is developed to analyze irreversible demagnetization under dynamic and transient states and considers a stator turn fault. The input current, circulating current, magnetic distribution characteristics, and operating property of the PM, including the irreversible demagnetization in the fault state, are analyzed using this algorithm by considering the magnetic saturation effect. The feasibility of the proposed method confirmed from the analysis results is verified via an experiment. Through this fault analysis, we can accurately check the fault phenomena of a PM motor against the demagnetization fault for fault prevention.

A Study of Analysis of Fault Data in AC Electrical Railway Power System Based on COMTRADE Using PSCAD/EMTDC (PSCAD/EMTDC를 활용한 COMTRADE 기반의 교류철도 급전계통 사고 데이터 분석에 관한 연구)

  • Lee, Ji-Hye;Min, Myung-Hwan;An, Tae-Pung;Lee, Byeong-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1542-1548
    • /
    • 2018
  • When any faults occurred in electrical railway system, operators need to analysis it quickly and accurately. Existing COMTRADE based analysis tools are not enough to analysis faults occurred in electrical railway system. In this paper, it presents some functions to fault analysis for electrical railway system based on fault data formatted COMTRADE. These functions are implemented in PSCAD/EMTDC and it can be shown that analyzed results against actual electrical fault cases which were occurred in the electrical railway power system.

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.