• Title/Summary/Keyword: FWHM

Search Result 656, Processing Time 0.031 seconds

A Study on configuration of a laser resonator with high alignment stability (높은 정렬 안정성을 갖는 레이저 공진기 구성에 관한 연구)

  • 차혁진
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.279-288
    • /
    • 2000
  • The variations of output energy due to tilt output coupler for different types of pulsed Nd:YAG laser resonators were compared by measuring FWHM (full width at half maximum) which means the width of angle displacement where maximum output energy decreases to half value. We proposed a new configuration of pulsed solid-state laser resonator which had high FWHM for tilting of output coupler and which was little sensitive for tilting of rear optics. We proved that our laser resonator had high alignment stability using ABeD ray matrix method because the ray matrix of such a resonator corresponded to unit matrix. atrix.

  • PDF

A study on the crystallinity of AlN single crystals by heat treatment (열처리에 따른 AlN 단결정의 결정성에 관한 연구)

  • Kang, Seung-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.105-109
    • /
    • 2017
  • AlN single crystal was thermally treated at $1200^{\circ}C$ and $1500^{\circ}C$ in the ambient gas of nitrogen. AlN single crystal was obtained by sublimation growth process using by a facility having a growth part which was heated by RF (Radio Frequency) induction heating. In this report, the optical microscopic results taken from thermally treated AlN single crystal and FWHM (Full width of half maximum) measured by DCXRD (Double crystal X-ray Diffractometry) were reported.

자동관측 망원경을 위한 자동 초점 알고리즘 개발

  • Yun, Yo-Ra;Lee, Chung-Uk;Im, Hong-Seo;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.65.2-65.2
    • /
    • 2011
  • 천체관측에서 가장 중요한 요소인 초점은 관측된 영상의 활용가치를 좌우하게 된다. 관측자가 직접 관측하는 망원경의 경우 직접적인 확인을 통하여 초점을 맞추어 관측하지만, 관측자가 개입하지 않는 자동관측 망원경의 경우 초점을 맞추는 일은 생각처럼 쉬운 일이 아니다. 자동으로 초점을 맞추기 위하여 기본적으로 활용되는 변수는 FWHM(Full with Half Maximum)이며, 초점이 전혀 맞지 않는 영상의 경우 FWHM을 결정할 수 없으며, 자동관측 망원경의 경우 관측된 영상을 전부 사용할 수 없게 된다. 본 연구에서는 초점이 전혀 맞지 않는 경우에도 초점을 맞출 수 있도록 FWHM을 활용하지 않고 별상의 크기를 직접 계산하여 좋은 초점을 맞출 수 있는 프로그램을 개발하였으며, 새로 개발한 프로그램은 결과 도출시간이 빠르고 광축이 맞지 않은 영상에서도 활용할 수 있어 활용성을 극대화 하였다. 한편, 리눅스 및 윈도우 기반의 영상 관측 컴퓨터에서도 활용할 수 있어 앞으로 활용성이 더 많아 질 것으로 기대한다.

  • PDF

Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors (SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

Effects of the V/III ratio on a-plane GaN epitaxial layer on r-plane sapphire grown by HVPE (r-Plane sapphire 위에 HVPE에 의해 성장한 a-plane GaN에피텍셜층의 V/III족 ratio에 따른 특성 변화)

  • Ha, Ju-Hyung;Park, Mi-Seon;Lee, Won-Jae;Choi, Young-Jun;Lee, Hae-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.3
    • /
    • pp.89-93
    • /
    • 2014
  • In this study, effects of the V/III ratio on a-plane GaN epitaxial on r-plane grown by HVPE have been investigated. According to increasing of V/III ratio, the value of FWHM of a-plane (11-20) GaN and the value of surface roughness (Ra) were decreased. Growth rate of a-plane GaN epitaxial layer were increased until V/III ratio = 7 as the increasing of V/III ratio, but it was reduced at V/III ratio = 10. At V/III ratio = 10, the FWHM of a-plane (11-20) GaN RC and the surface roughness (Ra) were 829 arcsec and 1.58 nm, respectively, as the lowest value in this study. Also for V/III ratio = 10, cracks under surface or voids were observed the lowest values in images of optical microscope. An M-shaped azimuthal dependence over $360^{\circ}$ angle range was observed for all samples. At V/III ratio = 10, the difference of FWHM of a-plane GaN between $0^{\circ}$ and $90^{\circ}$ was 439 arcsec revealed as the lowest value in the 4 samples.

Design and Evaluation of IMI Multilayer Hybrid Structure-based Performance Enhanced Surface Plasmon Resonance Sensor for Biological Analysis (생물학적 분석용 IMI 하이브리드 다중레이어 구조 기반 성능 향상된 표면 플라즈몬 공명 센서의 설계 및 특성 분석)

  • Song, Hyerin;Ahn, Heesang;Kim, Kyujung
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.4
    • /
    • pp.177-186
    • /
    • 2022
  • The performance of a surface plasmon resonance sensor is evaluated based on the sensitivity (nm/RIU) and sharpness from the full width at half maximum (FWHM) and the peak depth of a resonance peak. These factors are determined by the materials and conformational properties of the sensing structure. In this paper, we investigated an optimized insulator-metal-insulator (IMI) multilayer-based surface plasmon resonance sensor structure to simultaneously achieve high sensitivity, narrow FWHM, and deep peak depth while using gold for the metallic film layer which occurs peak broadening. By adopting the optimized structure, sensitivity of 8,390 nm/RIU, FWHM of 11.92 nm, and a resonance peak depth of 93.1% were achieved for 1.45-1.46 refractive index variation of the sensing layer. With the suggested structure conformation, high sensitivity and resolution of sensing performance can be achieved.

Statistical Study of Oscillating stars with Kepler data

  • Kim, Ki-Beom;Chang, Heon-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.88.3-88.3
    • /
    • 2015
  • Kepler mission is performing the quantitative and qualitative observations. Hence, it is possible to statistically study, which is called 'Ensemble asteroseismology', about seismic properties. They investigated about global oscillation parameters. In this study, we performed statistically study about global seismic parameters with Kepler data. Relation between global oscillation parameters (${\Delta}{\nu}$ and ${\nu}max$) are approximately confirmed. We investigated newly about distribution of Full-With-at-Half-Maximum (FWHM) and relation between FWHM and other global oscillation parameters.

  • PDF

Development of multi-repetitive Pulse Compression System for excimer laser excitation (엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구)

  • 전상영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF

Design and performance study of fabry-perot filter based on DBR for a non-dispersive infrared carbon dioxide sensor (비분산적외선 CO2 센서를 위한 DBR기반의 패브리 페로-필터 설계 및 성능 연구)

  • Do, Nam Gon;Lee, Junyeop;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.250-254
    • /
    • 2021
  • A highly sensitive and selective non-dispersive infrared (NDIR) carbon dioxide gas sensor requires achieving high transmittance and narrow full width at half maximum (FWHM), which depends on the interface of the optical filter for precise measurement of carbon dioxide concentration. This paper presents the design, simulation, and fabrication of a Fabry-Perot filter based on a distributed Bragg reflector (DBR) for a low-cost NDIR carbon dioxide sensor. The Fabry-Perot filter consists of upper and lower DBR pairs, which comprise multilayered stacks of alternating high- and low-index thin films, and a cavity layer for the resonance of incident light. As the number of DBR pairs inside the reflector increases, the FWHM of the transmitted light becomes narrower, but the transmittance of light decreases substantially. Therefore, it is essential to analyze the relationship between the FWHM and transmittance according to the number of DBR pairs. The DBR is made of silicon and silicon dioxide by RF magnetron sputtering on a glass wafer. After the optimal conditions based on simulation results were realized, the DBR exhibited a light transmittance of 38.5% at 4.26 ㎛ and an FWHM of 158 nm. The improved results substantiate the advantages of the low-cost and minimized process compared to expensive commercial filters.