• Title/Summary/Keyword: F-18 FDG-PET/CT

검색결과 330건 처리시간 0.036초

Comprehensive Updates in the Role of Imaging for Multiple Myeloma Management Based on Recent International Guidelines

  • Koeun Lee;Kyung Won Kim;Yousun Ko;Ho Young Park;Eun Jin Chae;Jeong Hyun Lee;Jin-Sook Ryu;Hye Won Chung
    • Korean Journal of Radiology
    • /
    • 제22권9호
    • /
    • pp.1497-1513
    • /
    • 2021
  • The diagnostic and treatment methods of multiple myeloma (MM) have been rapidly evolving owing to advances in imaging techniques and new therapeutic agents. Imaging has begun to play an important role in the management of MM, and international guidelines are frequently updated. Since the publication of 2015 International Myeloma Working Group (IMWG) criteria for the diagnosis of MM, whole-body magnetic resonance imaging (MRI) or low-dose whole-body computed tomography (CT) and 18F-fluorodeoxyglucose positron emission tomography/CT have entered the mainstream as diagnostic and treatment response assessment tools. The 2019 IMWG guidelines also provide imaging recommendations for various clinical settings. Accordingly, radiologists have become a key component of MM management. In this review, we provide an overview of updates in the MM field with an emphasis on imaging modalities.

감염성 골질환의 핵의학 영상진단 (Nuclear Medicine Imaging Diagnosis in Infectious Bone Diseases)

  • 최윤영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권4호
    • /
    • pp.193-199
    • /
    • 2006
  • Infectious and inflammatory bone diseases include a wide range of disease process, depending on the patient's age, location of infection, various causative organisms, duration from symtom onset, accompanied fracture or prior surgery, prosthesis insertion, and underlying systemic disease such as diabetes, etc. Bone infection may induce massive destruction of bones and joints, results in functional reduction and disability. The key to successful management is early diagnosis and proper treatment. Various radionuclide imaging methods including three phase bone scan, Ga-67 scan, WBC scan, and combined imaging techniques such as bone/Ga-67 scan, WBC/bone marrow scan add complementary role to the radiologic imaging modalities including plain radiography, CT and MRI. F-18 FDG PET imaging also has recently been introduced in diagnosis of infected prosthesis and chronic active osteomyelitis. Selection of proper nuclear medicine imaging method will improve the diagnostic accuracy of infections and inflammatory bone diseases, based on understading of pathogenesis and radiologic imaging findings.

PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰 (The Usefulness of Q.Clear Technique in PET / CT)

  • 최용훈;김정열;최영숙;임한상;김재삼
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.31-36
    • /
    • 2017
  • 최근 PET/CT 장비의 성능의 발전과 다양한 기법의 개발로 민감도와 해상도등 영상 품질을 개선할 수 있게 되었다. 본 논문에서는 GE사의 Discovery IQ 장비의 Q.Clear (a fully convergent iterative reconstruction) 기법을 이용하여 영상의 질 향상에 유용성이 있는지 알아보고자 한다. 장비는 Discovery IQ (GE Healthcare, MI, USA)를 사용하였다. NEMA IEC Body Phantom의 배후방사능과 열소 체적(10 mm, 13 mm, 17 mm, 22 mm)의 비를 1:4로 하고 3분간 촬영하여 VPHDs (VUE Point High-Definition SharpIR)와 Q.Clear의 대조도를 비교 분석하였다. PET/SPECT Performance Phantom에 $^{18}F-FDG$를 187 MBq을 주입 후 4분간 촬영하여 해상도와 균일도를 비교 분석하였다. 그리고 100명의 임상 환자에서 질환의 종류와 상관없이 2 cm 미만의 작은 병소의 SUVmax를 측정하여 t-test 통계분석하였다. NEMA IEC Body Phantom에서 VPHDs와 Q.Clear의 대조도가 $63.6{\pm}5.7%$, $75{\pm}4.8%$로 나왔고 PET/SPECT Performance Phantom에서 해상도는 VPHDs가 9.2 mm, Q.Clear가 7.3 mm로 나왔다. 균일도는 Q.Clear가 10.8% 더 우수하였다. 임상 환자의 t-test 통계 결과 p-value가 0.021로 유의한 차이가 있었다. 임상환자에서 SUVmax는 Q.Clear에서 높게 측정 되었으며, 신호대 잡음 비도 우수하였다. 이는 부분체적효과의 영향을 줄였기 때문으로 볼 수 있다. Phantom test와 임상 환자의 결과 모두 Q.Clear를 적용 하였을 때 영상품질이 향상된 것을 확인하였다. 이러한 영상 품질 향상은 병소를 더욱 정확하게 발견할 수 있고 나아가 선량저감과 환자평가 그리고 영상 분석 등 다양한 방면에서 활용할 수 있을 것으로 사료된다.

  • PDF

PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교 (A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT)

  • 이승재;박훈희;안샤론;오신현;남궁혁;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • PET/CT 검사의 사용 초기에 CT는 주로 감쇠보정(Attenuation Correction: AC)의 목적으로 사용되어졌지만, CT의 성능이 향상됨으로써 조영제를 이용한 CT검사를 진단에 반영하여 보다 진보된 진단적 가치를 가질 수 있게 되었다. 조영제의 사용이 없이도 CT를 판독할 수 있지만 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 있어서 조영제의 사용은 판독자로 하여금 판독을 매우 용이하게 하는 도움을 줄 수 있다. 하지만, 그동안 PET/CT검사 시 조영제가 감쇠보정에 영향을 줄 수 있다는 논쟁으로 이견이 많았다. 40-140 keV 정도의 낮은 엑스선을 이용하는 CT영상에 비하여, 조영제를 사용한 CT영상에서는 조영제로 인해 감쇠가 많이 되지만 511 keV의 에너지를 가진 감마선은 조영제로 인해 거의 영향을 받지 않게 되고 이로 인해 감쇠보정 시 과보정을 하게 되어 PET영상에서 오류를 나타낼 수 있다는 의견이 보고되기도 하였다. 이와는 반대로 조영제가 감쇠보정에 과대평가를 가져올 수 있다는 의견과 과보정으로 인한 표준화섭취계수에 변화의 가능성은 있으나 결정적인 영향을 미치지 않는다는 의견도 제시되었다. 본 연구에서는 조영제의 영향이 SUV에 어떠한 영향을 미치는지에 대해서만 비교 평가하였다. 2007년 12월에서 2008년 6월 사이에 본원에서 PET/CT 검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 진행성 암 환자 30명을 대상으로 하였으며, DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하여, 각각의 환자는 조영제를 사용하지 않은 CT를 시행한 후 PET영상을 얻었고 그 후, 조영제를 사용한 CT검사를 하였다. 각각의 CT정보로 감쇠보정을 실시, 종류별로 PET영상을 획득하여, 각 영상에 동일한 관심영역(Region of Interests : ROIs)을 설정 후, SUV를 비교 하였다. 얻어진 두 가지 결과 값의 정량 분석의 비교를 위해서 대응표본 T-검정 (Paired t-test)을 사용하였다. 검사를 시행한 30명의 환자에게서 폐, 간, 심장의 $SUV_{max}$ 값과 $SUV_{mean}$값을 측정하여 총 180개 영역을 분석하였다. 조영제를 사용하기 전과 후를 비교하였을 때, 측정한 거의 모든 영역에서 조영 후의 $SUV_{max}$$SUV_{mean}$가 상승하였고 통계적으로도 유의한 것으로 나타났다(p value<0.05). 심장 영역에서 조영 전 보다 조영 후의 $SUV_{mean}$값이 증가된 것으로 나타났지만, 통계적으로 유의하게 나타나지는 않았다. 조영제를 사용한 CT영상의 SUV값이 과보정되어, 조영제를 사용하지 않은 CT의 SUV 보다 높게 나왔으나 기존의 보고된 논문에서는 이와 같은 결과는 실제 임상 판독에 있어서 큰 영향을 미치지 않는다고 보고되어 있다. 그러나 원발성병변의 진행을 알아보는 과정에서는 SUV의 작은 변동도 분명 영향을 줄 수 있으므로 간 영역과 같이 SUV의 변동이 다른 영역에 비해 상대적으로 큰 영역에서는 수치의 변화에 대한 주의가 요구 될 것으로 사료된다.

  • PDF

Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성 (Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image)

  • 문아름;지용기;최성욱;이혁;이규복;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.18-23
    • /
    • 2010
  • 최근 PET/CT영상의 발달로 종양의 진단 및 평가를 통해 임상에 많은 도움을 주고 있다. 특히 PET와 CT를 융합한 Fusion PET/CT영상이나 2차원 PET영상을 3차원 영상으로 재구성한 최대강도영상(Maximum Intensity Projection)은 전체적인 병변을 한눈에 시각화하는 데 유용하게 쓰이고 있다. 하지만 Fusion & MIP 3D 재구성 영상에서 $^{18}F$-FDG의 생리적 배출로 소변이나 요루주머니에 의한 열소가 나타나 병변이 겹쳐져 육안적으로 병변을 구별하는 데 어려움이 있다. 본 연구에서는 소변에 의해 나타나는 열소 부위를 제거하여 병변의 분별력을 향상하고자 한다. 2008년 9월부터 2009년 3월까지 내원한 환자 중 PET/CT 검사에서 자궁, 방광, 직장 부위의 질환으로 잔존하는 소변량이 많은 환자들을 대상으로 하였다. 분석장비는 GE사의 Advantage Workstation AW4.3 05 버전 Volume Viewer 프로그램을 사용하였다. 분석 방법은 2D PET axial volume 영상에서 제거하고자 하는 region에 ROI를 설정하여 Cut Outside를 선택한 후 coronal volume 영상도 동일한 방법을 적용한다. 다음으로 3D Tools의 threshold 값을 지정하고, Advanced Processing에서 Subtraction을 선택하여 차집합 방식으로 소변 영상만을 소거한다. 이렇게 Region Cut Subtraction이 된 2D PET영상과 CT영상으로 Fusion영상과 MIP영상을 만들어 Region Cut Subtraction하지 않은 영상과 비교한다. Fusion & MIP 3D 재구성 영상에서 Advantage Workstation AW4.3 05버전의 Region Cut Subtraction으로 환자의 소변이나 요루주머니에 의한 열소 부위를 제거할 수 있었다. Region Cut Definition을 사용한 영상에서 그렇지 않은 영상보다 소변 섭취 때문에 구별이 어렵던 병변과의 경계가 보다 명확하게 재구성되었다. 영상을 재구성하는 과정에서 Region Cut Subtraction을 사용하여 열소 부위를 제거한다면 기존에 사용하던 단순 역치범위 설정에 의한 영상 소거법보다 우수한 진단적 정보를 제공할 것이다. 특히 방광, 자궁, 직장 부위 질환의 경우, 판독의와 임상의에게 판독에 보다 유용한 영상 정보를 제공하고, 영상의 질적 향상에 도움이 될 것이라 판단된다.

  • PDF

PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰 (Study to Protocol of PET Acquisition Time for Patient Body Type in PET/CT)

  • 조석원;함준철;강천구;반영각;이승재;임한상;이창호;박훈희
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.72-77
    • /
    • 2013
  • Purpose: Whole-body PET using radiopharmaceutical is one of the imaging study methods for physiological changes of body. High specificity of the PET-CT examination is used to detect an early stages of cancer and metastatic cancer by imaging a physiological changes. During the imaging process, PET image has been characterized by a relatively low image quality due to its low sensitivity and the acquisition of random and scatter coincidences as well as patients figure. Therefore, the image quality as the changes of the acquisition times of patient weight was evaluated in this study. Materials and Methods: Thirty patients who presented to our hospital were enrolled. They were divided to normal, overweight, and obese group using BMI index, respectively. The patients with a liver disease and diabetes were excluded. $^{18}F-FDG$ was administered to the patients as 5.2 MBq per kg. After an hour from an injection, image acquisition was obtained as List mode in a part of liver in 1 bed. SNR (signal-to-noise ratio) of each groups acquisition times were confirmed from the calculated radiation counts and random fractions. The statistical significance of three groups was confirmed through one-way ANOVA test. On the basis of the counts of 2 minutes on normal group, the SNR of overweight group and obese group were compared. Results: The SNR were increased with loger aquisition time in 3 groups. In the condition of same acquisition time, the SNR had a statistical significance (P<0.05). The SNR were decreased to the normal, overweight, and obese, respectively. Liver activity had no significance difference on each group and RF had the significance differences (P<0.05). On the basis of the counts of 2 minutes on normal group, there were no statistical significance in a three minute acquisitions of overweight group and two minute acquisitions of obese group (P=0.150). Conclusion: In this study, the administrated amount of radiation dose did not adjust as the change of the patients weight. Increasing the acquisition time when the administration of the same amount of dose was able to get a good result of SNR. When the Based 2 minute on normal group, if overweight and obese case the increased acquisition time of 3 minute was able to obtain a similar SNR. On the basis of the normal group, the acquisition times of overweight and obese group were increased to 3 minutes per bed and the SNR were similar to the normal group.

  • PDF

PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성 (Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction)

  • 최성욱;최춘기;이규복;석재동
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.171-175
    • /
    • 2008
  • 목적 : 소아환자는 성인과는 다르게 작은 체구로 인하여 병소의 위치확인과 정량평가하기에 다소 어려움이 있다. 저자들은 phantom 실험과 소아환자를 대상으로 PET/CT에서의 영상재구성 시 DFOV 변화에 따른 SUV값의 유용성을 평가하였다. 실험재료 및 방법 : Uniform NU2-94 Phantom에 0.023 MBq/cc의 $^{18}F$-FDG를 채운 후 10 min 동안 얻었으며, 재구성시 DFOV는 50, 45, 40, 35, 30, 25 cm로 변화를 주었다. 환자 영상은 2007년 10월부터 2008년 1월까지 소아 암 진단을 받았거나 의심되는 20명, 영상재구성 시 DFOV는 50~25 cm 까지 각 5 cm 변화를 주었다. phantom과 소아 환자의 재구성 된 영상에서 DFOV 변화에 따라 각각의 pixelsize와 $SUV_{max}$ 값 변화를 비교 분석하였다. 결과 : phantom실험에서 DFOV가 50, 45, 40, 35, 30, 25 cm로 감소함에 따라 pixel size는 각각 3.906, 3.515, 3.125, 2.734, 2.343, 1.953 mm로 감소하였고, $SUV_{max}$는 각각 1.275, 1.323, 1.359, 1.418, 1.524, 1.685로 증가를 보였다. 환자 영상에서는 DFOV 50 cm를 기준으로, $SUV_{max}$는 4.629, 4.786, 4.995, 5.231, 5.373, 5.659의 증가 변화와. 11.9, 12.22, 12.43, 12.52, 12.80, 13.23으로 증가를 나타냈다. 또한 DFOV 5 cm가 감소하면서 40 cm 까지는 좋은 영상을 얻을 수 있었지만, DFOV 35 cm 부터는 truncated artifact가 나타나는 것을 알수 있었다. 결론 : phantom을 이용한 $SUV_{max}$ 값은 DFOV가 5 cm씩 감소함에 따라 평균 수치가 증가하였으며, DFOV 50 cm를 기준으로 각각 3.7, 6.5, 11.2, 19.5, 32.1%로 증가함을 알았다. 소아환자 영상에서도 DFOV가 감소함에 따라 phantom 실험에서와 같이 증가하는 양상을 보였다. 영상 재구성 시 matrix size의 변화 없이 DFOV를 감소시키는 것만으로도 pixel size가 줄어들기 때문에 영상의 질을 향상시킬 수 있으며, 이는 소아 환자의 영상을 성인에서와 같은 방법으로 재구성한 후 확대하여 보는 것 보다 효과적이라 할 수 있다. 그러나 DFOV를 35 cm 이하로 적용할 경우 truncated artifact가 발생할 수 있으므로 제한적으로 적용해야 할 것이라 생각된다. 그러므로 DFOV의 변화는 소아 환자에 보다 좋은 영상을 얻을 수 있지만, 영상 판독은 DFOV의 변화에 따른 SUV값의 변화를 고려해야 할 것으로 사료된다.

  • PDF

GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이 (Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT)

  • 김진수;이재성;이동수;박은경;김종효;김재일;이홍재;정준기;이명철
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.182-190
    • /
    • 2005
  • 목적: CT기반 감쇠보정 영상의 표준섭취계수(Standard Uptake Value:SUV)가 $^{137}Cs$ 기반 감쇠보정 영상의 SUV보다 높다. 이 연구에서는 이러한 오차가 생기는 원인을 밝히고자 감쇠계수가 정확하게 변환되었는지 여부를 관심영역 분석을 통하여 평가하였다. 대상 및 방법: Philips GEMINI PET/CT는 X-ray CT (평균 40 keV) 혹은 $^{137}Cs$ (662 keV) 투과영상을 감쇠보정에 이용하는데 GEMINI PET/CT에서 사용하는 각각 선원의 에너지는 511 keV에서 얻은 감쇠계수와 틀리기 때문에 스캐너 내부에 장착된 감쇠계수 변환 알고리즘을 이용하여 511 keV에 해당하는 감쇠계수 값으로 변환된 감쇠지도를 사용하므로 감쇠계수의 변환이 정확하게 이루어졌는지 평가하는 것이 중요하다. 각각의 실험과정은 다음과 같다. 먼저 시스템 성능평가 팬텀 CT 투과 영상을 사용하여 Hounsfield units (HU)값을 측정하였다. 다음으로 NEMA 타원형 ECT 팬텀의 CT, $^{137}Cs$ 투과영상을 얻어 $^{68}Ge$ 투과선원을 장착한 Siemens ECAT EXACT 47 PET 스캐너에서 얻은 팬텀 투과 영상과 비교하여 감쇠계수가 511 keV에 해당하는 감쇠계수로 잘 변환되었는지 측정하였고 Gammex 467 electron density CT 팬텀의 CT, $^{137}Cs$ 투과영상에서 관심영역 분석을 하여 다양한 전자밀도 값에 대한 감쇠계수 변환의 정확성을 평가하였다. 또, 재구성한 영상에 미치는 영향을 평가하기 위하여 정상 및 병적 조직에서 CT, $^{137}Cs$ 기반 감쇠계수와 표준섭취계수를 비교하였다. 결과: CT에서 측정한 HU는 신뢰할 수 있는 값임을 확인하였으나 전자밀도와 원자번호가 큰 영역에서 CT 기반 감쇠계수에 오차가 있었는데 NEMA 타원형 ECT 팬텀 실험결과에 의하면 뼈 영역에서 오차는 11%이었다. 임상데이터에서도 마찬가지로 CT를 이용하여 얻은 감쇠계수가 $^{137}Cs$을 이용하여 얻은 감쇠계수보다 낮았고 전자밀도와 원자번호가 큰 영역에서 오차가 컸다. 그러나, 표준섭취계수는 $^{137}Cs$를 사용하여 감쇠보정을 한 영상의 값이 CT를 이용하여 감쇠보정을 한 값보다 오히려 낮았고 표준섭취계수의 백분율 차이는 $6.6{\sim}52.7%$이었다. 결론: CT의 HU가 정확함에도 불구하고 뼈 영역에서 CT 투과영상을 기반으로 한 감쇠계수의 변환이 부정확하고 CT 및 $^{137}Cs$ 투과영상을 기반으로 얻은 표준 섭취계수에 차이가 있으므로 이에 관한 추가적인 연구가 필요할 것으로 생각한다.

PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가 (Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image)

  • 박선명;이혁;홍건철;정은경;최춘기;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.41-46
    • /
    • 2011
  • 영상장치를 이용한 검사 시 영상의 질은 검사결과와 밀접하게 연관되어 있으며, 이는 영상획득 조건들과 이에 대한 평가방법으로 인해 달라 질 수 있다. 본 연구에서는 영상획득 시 사전설정법(Pre-set method)차이에 따른 영상의 질을 평가하였다. 장비는 PET/CT Discovery STe16(GE Healthcare, Milwaukee, USA)을 사용하였으며, Chest PET Phantom (실험 1)과 94 NEMA Phantom (실험 2)을 이용하였다. 실험 1의 경우 3.5, 6.0, 8.6 kBq/mL, 실험 2의 경우는 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL의 $^{18}F$-FDG를 채웠고, 열소와 배후방사능과의 방사능 농도는 4:1의 비율을 유지하였다. 각 실험은 CT 투과촬영 후 3D로 2분 30초/프레임으로 시간설정법(Time-set method)과 1억 계수의 계수설정법 (Count-set method)을 적용하여 방출촬영 하였다. 영상의 질에 대한 평가는 잡음 등가 계수율 (Noise Equivalent Count Rate, NECR)과 신호 대 잡음비 (Signal to Noise Ratio, SNR)를 이용하였다. 실험 1에서 NECR과 SNR은 방사능 농도의 증가에 따라 시간설정법에서 53.7, 66.9, 91.4 과 7.9, 10.0, 11.7로 평가 모두에서 증가함을 보였으나, 계수설정법은 53.8, 69.1, 97.8과 14.1, 14.7, 14.4로 SNR은 NECR과 다르게 증감현상을 보이지 않았다. 또 다른 모형실험인 실험 2에서도 NECR과 SNR은 방사능 농도가 증가에 따라 시간설정법에서 45.1, 70.6, 95.3 115.6 134.6 162.2 과 7.1, 8.8, 10.6, 11.5, 12.7, 14.0으로 증가함을 보였으나, 계수설정법에서는 42.1 67.3 92.1 112.2 130.7 158.7 과 15.2, 15.9, 15.6, 15.4, 15.5, 14.9로 실험 1에서와 마찬가지로 SNR에서는 증감현상을 보이지 않았다. 사전설정법 변화와 관계없이 단위 질량당 방사능량 증가는 영상의 질도 비례하여 향상된다. 그러나 동일한 단위 질량당 방사능량에서는 영상획득의 시간을 늘려 총계수값을 증가시켜도 NECR에 영향을 주지는 않는다. 이는 NECR을 이용한 영상 질 평가는 영상획득 시 얻은 총 계수 값보다는 단위 시간당의 계수율이 영향을 준다는 것을 의미한다고 할 수 있다. 실험 모두에서 계수설정법으로 얻은 경우에는 단위 질량당 방사능량의 증가에도 불구하고 거의 비슷한 SNR값을 보이게 된다. 따라서 좋은 질의 영상을 얻기 위해서는 총 계수값의 증가보다는 단위질량당 방사능량을 높여야 하며, SNR만을 이용한 영상의 질에 대한 평가는 적절하지 않을 수 있다는 점을 고려하여야 한다.

  • PDF