Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image

Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성

  • Moon, A-Reum (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Chi, Yong-Gi (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Choi, Sung-Wook (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Lee, Hyuk (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Lee, Kyoo-Bok (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Seok, Jae-Dong (Department of Nuclear Medicine, Samsung Medical Center)
  • 문아름 (삼성서울병원 핵의학과) ;
  • 지용기 (삼성서울병원 핵의학과) ;
  • 최성욱 (삼성서울병원 핵의학과) ;
  • 이혁 (삼성서울병원 핵의학과) ;
  • 이규복 (삼성서울병원 핵의학과) ;
  • 석재동 (삼성서울병원 핵의학과)
  • Received : 2010.01.04
  • Accepted : 2010.01.18
  • Published : 2010.06.05

Abstract

Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

최근 PET/CT영상의 발달로 종양의 진단 및 평가를 통해 임상에 많은 도움을 주고 있다. 특히 PET와 CT를 융합한 Fusion PET/CT영상이나 2차원 PET영상을 3차원 영상으로 재구성한 최대강도영상(Maximum Intensity Projection)은 전체적인 병변을 한눈에 시각화하는 데 유용하게 쓰이고 있다. 하지만 Fusion & MIP 3D 재구성 영상에서 $^{18}F$-FDG의 생리적 배출로 소변이나 요루주머니에 의한 열소가 나타나 병변이 겹쳐져 육안적으로 병변을 구별하는 데 어려움이 있다. 본 연구에서는 소변에 의해 나타나는 열소 부위를 제거하여 병변의 분별력을 향상하고자 한다. 2008년 9월부터 2009년 3월까지 내원한 환자 중 PET/CT 검사에서 자궁, 방광, 직장 부위의 질환으로 잔존하는 소변량이 많은 환자들을 대상으로 하였다. 분석장비는 GE사의 Advantage Workstation AW4.3 05 버전 Volume Viewer 프로그램을 사용하였다. 분석 방법은 2D PET axial volume 영상에서 제거하고자 하는 region에 ROI를 설정하여 Cut Outside를 선택한 후 coronal volume 영상도 동일한 방법을 적용한다. 다음으로 3D Tools의 threshold 값을 지정하고, Advanced Processing에서 Subtraction을 선택하여 차집합 방식으로 소변 영상만을 소거한다. 이렇게 Region Cut Subtraction이 된 2D PET영상과 CT영상으로 Fusion영상과 MIP영상을 만들어 Region Cut Subtraction하지 않은 영상과 비교한다. Fusion & MIP 3D 재구성 영상에서 Advantage Workstation AW4.3 05버전의 Region Cut Subtraction으로 환자의 소변이나 요루주머니에 의한 열소 부위를 제거할 수 있었다. Region Cut Definition을 사용한 영상에서 그렇지 않은 영상보다 소변 섭취 때문에 구별이 어렵던 병변과의 경계가 보다 명확하게 재구성되었다. 영상을 재구성하는 과정에서 Region Cut Subtraction을 사용하여 열소 부위를 제거한다면 기존에 사용하던 단순 역치범위 설정에 의한 영상 소거법보다 우수한 진단적 정보를 제공할 것이다. 특히 방광, 자궁, 직장 부위 질환의 경우, 판독의와 임상의에게 판독에 보다 유용한 영상 정보를 제공하고, 영상의 질적 향상에 도움이 될 것이라 판단된다.

Keywords