• Title/Summary/Keyword: Eye temperature

Search Result 167, Processing Time 0.025 seconds

The High Temperature-Moisturizing Method for Obtaining Quality Postmortem Fingerprints from Decomposed Fingers

  • Kim, Young-Sam;Park, Hee-Chan;Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.13 no.4
    • /
    • pp.369-374
    • /
    • 2007
  • A fingerprint is an impression of the friction ridges of all or any part of the finger. A friction ridge is a raised portion of the epidermis on the palmar (palm and fingers) or plantar (sole and toes) skin, consisting of one or more connected ridge units of friction ridge skin. There are two fundamental principles underlying the use of fingerprints as a means of identifying individuals - immutability and uniqueness. Friction ridges develop on the fetus in their definitive form before birth. Ridges are persistent throughout life except for permanent scarring. Ridge patterns and the details in small areas of friction ridges are unique and never repeated. Friction ridge patterns vary within limits, which allow for classification. We developed the high temperature-moisturizing method to obtained quality postmortem impressions from decomposing friction ridge skin. This technique is a simple procedure that uses boiling water to recondition the skin. This reconditioning process enhances detail present on the fingers and exposes ridge detail not visible to the naked eye. Therefore, we can recover the quality fingerprints, even from the worst decomposed bodies.

  • PDF

Visibility Enhancement of Laccase-Based Time Temperature Integrator Color by Increasing Opacity

  • Kim, Hyun Chul;Cha, Hee Jin;Shin, Dong Un;Koo, Yong Keun;Cho, Hye Won;Lee, Seung Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.27 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • Time-temperature integrators (TTIs) based on aqueous enzyme solutions produce transparent colors which lead to difficulty in distinguishing its color change by naked eye. In this present study, this issue has been solved by increasing the opacity of laccase-based TTI without changes in the kinetics (same zero-order reaction) and temperature dependency (similar Arrhenius activation energy values) of the color change. The opacity was increased by introducing TiO2, latex, BaSO4, or ZnO, in combination with a hydrocolloid (xanthan gum, acacia gum, pectin, and CMC) into the TTI system. The combination of TiO2 and xanthan gum was the best. This finding broadened the advantages of laccase-based TTI to more practical uses for consumer convenience.

Measurement of Wax Appearance Temperature Using Image Processing (영상 처리기법을 이용한 오일의 왁스생성온도 측정)

  • Hwang, Soon-Hye;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • When the oil is produced in the low temperature environment, wax can be accumulated in petroleum production system(pipeline, riser) and causes problems such as pipeline stucking, disturbance of the oil production. These problems can be lead to time-consuming and economic losses for flow assurance. For prediction and mitigation of wax deposition, it is necessary to measure the Wax Appearance Temperature(WAT) which is a temperature when the wax crystals start to be formed. WAT standard measurement method of transparent oil has to determine the cloud point of sample to the naked eye and cannot be applied to continuous change of the temperature. In this study, wax behavior of transparent oil samples are recorded depending on temperature using Visualized WAT Measurement System. Also, WATs of transparent oil samples are measured by image processing and compared with the result of the standard method.

Seasonal Variation in Carcass Characteristics of Korean Cattle Steers

  • Piao, M.Y.;Baik, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.3
    • /
    • pp.442-450
    • /
    • 2015
  • Climate temperature affects animal production. This study was conducted to evaluate whether climatic conditions affect beef carcass characteristics of Korean cattle steers. The monthly carcass characteristics of Korean cattle steers (n = 2,182,415) for 8 yr (2006 through 2013) were collected from the Korean Institute for Animal Products Quality Evaluation. Daily climate temperature (CT) and relative humidity (RH) data were collected from the Korean Meteorological Administration. Weather conditions in South Korea during summer were hot and humid, with a maximum temperature of $28.4^{\circ}C$ and a maximum RH of 91.4%. The temperature-humidity index (THI), calculated based on CT and RH, ranges from 73 to 80 during summer. Winter in South Korea was cold, with a minimum temperature of $-4.0^{\circ}C$ and a wind-chill temperature of $-6.2^{\circ}C$. Both marbling score (MS) and quality grade (QG) of Korean cattle steer carcasses were generally best (p<0.05) in autumn and worst in spring. A correlation analysis showed that MS and QG frequencies were not associated (p>0.05) with CT. Yield grade (YG) of Korean cattle steer carcasses was lowest (p<0.05) in winter (November to January) and highest in spring and summer (May to September). A correlation analysis revealed that YG frequency was strongly correlated ($r{\geq}0.71$; p<0.01) with CT and THI values. The rib eye area, a positive YG parameter, was not associated with CT. Backfat thickness (BT), a negative YG factor, was highest in winter (November and December). The BT was strongly negatively correlated ($r{\leq}-0.74$; p<0.01) with CTs. Therefore, the poor YG during winter is likely due in part to the high BT. In conclusion, YG in Korean cattle steer carcasses was worst in winter. QGs were not associated with winter or summer climatic conditions.

Experimental Study on the Determination of Slope and Height of Curbs Considering the VRUs (교통약자를 고려한 보도의 경사도와 높이 결정을 위한 실험연구)

  • Kim, Hyunjin;Lim, Joonbeom;Choe, Byongho;Oh, Cheol;Kang, Inhyeng
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.107-115
    • /
    • 2018
  • PURPOSES : As the population of the mobility handicapped, who are classified as the disabled, the elderly, pregnant women, children, etc., has increased, the voices for guaranteeing their rights have been increasing as well. Thus, the design manuals for roads and sidewalks for the mobility handicapped were developed by the local government, such as the Ministry of Land, Transport, and Tourism, in Seoul City. However, according to the 2013 survey results of the Seoul Metropolitan City, the mobility handicapped still feel uncomfortable with the sidewalks, and particularly request for the improvement of the step and slope of the sidewalk curb. Therefore, in this study, we conducted an empirical experimental study to determine the slope of the sidewalk curb and height of the steps considering the mobility handicapped and analyzed whether there is a statistically significant difference. METHODS : The methodology of this study is an empirical experimental one. In the study, five non-disabled people, 10 wheelchair users, and 10 eye patch and stick users walked about 2-3 min on the sidewalk plates of the sloped type (0%, 5%, 6.3%, 8.3%) and stepped type (0 cm, 1 cm, 3 cm, 6 cm), and their human physiological responses, such as the skin temperature, volume of perspiration on forehead and chest, and heart rate, were measured and recorded. After combining the data, we conducted a nonparametric test, ANOVA, or t-test to determine whether there was a statistically significant difference according to each slope and step type. RESULTS : It was found that for the non-disabled, there was no significant difference in human physiological responses according to the slope and steps of the sidewalk. It can be said that the non-disabled do not feel much physiological discomfort while walking. In the case of the sloped sidewalk plate, the heart rate of the wheel chair users increased when the slope was 6.3%. In the case of the eye patch and stick users, the volume of perspiration on the chest increased at a slope of 5.0%. In general, it is judged that a sidewalk with a slope that is less than 5% does not cause a change in the physiological response. In the case of a stepped sidewalk plate, when 0 cm, 1 cm, and 3 cm were compared for wheelchair users, the amount of forehead perspiration increased from 1 cm. Meanwhile, in the case of the eye patch and stick users, when 0 cm and 6 cm were compared, the amount of perspiration on the forehead and chest as well as the heart rate all increased at 6 cm. Taken together, in the case of wheelchair users, a difference was shown when the height of the step of the sidewalk plate was 1 cm, suggesting that installing it at 0 cm does not cause any physiological discomfort. Moreover, in the case of the eye patch and stick users, when comparing only 0 cm and 6 cm, 0 cm was considered to be suitable, as there was a difference in physiological response at 6 cm. CONCLUSIONS : In this study, we set the human physiological responses such as chest skin temperature, amount of perspiration, and heart rate as evaluation items, and our study was considered to be a meaningful experiment that targeted wheelchair users as well as eye patch and stick users. The validity of the evaluation items was confirmed, as the results of human physiological responses were significant. As for the sidewalk design, according to the experiment result, it is considered that differential application should be implemented according to the type of mobility handicap, rather than uniformly applying a sidewalk step of 2 cm and sidewalk slope of 1/25, which are the current legal standards.

Improved Heat Lamp for Preventing Arterial Spasm after Microvascular Surgery (미세혈관 수술 후 혈관 연축의 예방을 위한 개선된 온열전등)

  • Ahn, Sung-Min;Hwang, So-Min;Hu, Eun-Suk;Park, Jung-Mi;Park, Kyung-A;Oh, Jin-A
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.120-125
    • /
    • 2008
  • Purpose: Heat therapy by heat lamp after microvascular surgery is being used for preventing blood vessels's contraction and blood-flow's disturbance. As usually, incandescent lamp has been used. But there have been several problems and need for improvement in the existing heat lamp treatment. So we would like to introduce improved heat lamp to keep an appropriate temperature and intensity of illumination. Methods: The existing heat lamps are the ones of general light stands covered with newspaper, having 60 watt light bulb of incandescence and lampshade made of aluminum. We have tried to improve shortcomings of the existing heat lamps by enlarging the size of aluminum lampshade and attaching a curtain that can block heat and light. We conducted a comparative study between the existing and improved heat lamps. Under the assumption that there are several affected parts, we have also measured the distance from heat lamp to patients' eye region and then intensity of illumination. Result: The target temperature of surface was realized in 11 minutes with the maximum temperature reaching at 36.6 degrees C in 28 minutes at the existing heat lamp while the target temperature reached in 7 minutes with the maximum temperature reaching at 39.0 degrees C in 17 minutes at the improved heat lamp. The existing and improved heat lamp showed 38 lx and 0.1 lx of intensity of lumination, respectively. Conclusion: Using improved heat lamps, we can keep an appropriate temperature and we think we can make contribution to patients' treatment by making them and their neighbors able to sleep with minimized disturbance thanks to low intensity of illumination secured by blocking light.

  • PDF

Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study

  • Kim, Young-Koo;Lee, Hae-Jin;Kim, Jihee
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.159-165
    • /
    • 2020
  • Background and Objectives The ultimate goal in current skin rejuvenation practice is to achieve a good result with minimal pain and downtime. Nonablative skin rejuvenation (NSR) is one technique. The efficacy of the long-pulsed 1064 nm Nd:YAG laser (LPNDY) has not been assessed in NSR. Materials and Methods Three target areas were selected (bilateral cheeks and glabellar region) in six volunteer subjects. A LPNDY with an integral skin temperature monitor delivered three stacked shots to each target area (1064 nm, 12 mm spot, 13 J/cm2, 1 Hz) without any skin cooling or anesthesia. The skin temperature was recorded before, during, and after each set of shots using the system monitor and in real-time using a high-sensitivity (±0.001℃) near-infrared video camera. The skin reaction was observed with the naked eye, and pain and discomfort were assessed by the subjects during and after treatment. Results The subjects reported a mild feeling of heat with no discomfort during or after the test treatments. Mild erythema was observed around the treatment areas, without noticeable edema. A series of three ascending skin temperature stepwise peaks, with a decrease in skin temperature towards the baseline after the third shot, was observed consistently. The mean temperatures for shots 1, 2, and 3 for the cheeks were 39.5℃, 42.0℃, and 44.4℃, respectively, and for the glabella, 40.8℃, 43.9℃, and 46.2℃, respectively. Similar ranges were indicated on the system integral temperature monitor. Conclusion A set of three stacked pulses with the LPNDY at a low fluence achieved ideal dermal temperatures to achieve some dermal remodeling but without any downtime or adverse events. The temperature data from the integral thermal sensor matched the video camera measurements with practical accuracy for skin rejuvenation requirements. These data suggest that LPNDY would satisfy the necessary criteria to achieve effective NSR, but further studies will be needed to assess the actual results in clinical practice.

An efficient production management of the silkworm variety "Daewhangjam" through low temperature in a pupa

  • Chan Young Jeong;Sang Kug Kang;Seong-Wan Kim;Hyun-Bok Kim;Jong Woo Park;Ji Hae Lee;Kee-Young Kim;Seong Ryul Kim
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.47 no.1
    • /
    • pp.44-50
    • /
    • 2023
  • The Daehwangjam has excellent marketability and quality. However, precise silkworm breeding data on the recent high-temperature environment is not enough collected, and it is necessary to check whether stable Daewhangjam silkworm egg production was possible in poor environments. In this study, the timing of metamorphosis of the Daewhangjam parents Jam323 and Jam324 silkworms, in an optimal condition and a general condition similar to breeding grounds, was investigated to confirm that appropriate mating was achieved. Surprisingly, a number of female moths were discarded due to the metamorphosis of Jam324 female moths much earlier than Jam323 male moths in either an optimal or a general condition. To improve this, during the Jam324 female pupation period, the mild low-temperature of 15℃ was treated for the pupation period to delay the metamorphosis into female moths. Depending on the treatment period, the metamorphosis of the female pupa was delayed by more than 4 days, allowing normal mating with the Jam323 male moth. The eye pigments in a pupa also slowly accumulated in these treatments. In order to discover the side effects of low-temperature treatments, the voltinism of the Daewhangjam eggs was investigated, but most of them remained univoltine. Taken together, the low-temperature treatment during the female pupation period made it possible to use Jam324 female moths that were should be discarded, which means that stable and efficient management of Daewhangjam egg production is possible.

Color Evolution in Single Crystal Colored Cubic Zirconias With Annealing Atmosphere and Temperature

  • Song, Jeongho;Noh, Yunyoung;Song, Ohsung
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.450-455
    • /
    • 2016
  • Color change in single-crystal, yellow, red, purple, and colorless cubic zirconias (CZs) was investigated as a function of annealing in vacuum and air atmosphere at $800-1400^{\circ}C$ for 30 min, for development of a damascene process of plugging a precious metal paste at the elevated temperature. Coloring-element contents of the CZs were evaluated using WD-XRF, and the color change determined visually by naked eye, and using a digital camera and UV-Vis-NIR color analyzer. WD-XRF showed that all of the CZs had cubic-phase stabilizer elements and coloring elements. All CZs that underwent vacuum annealing exhibited a slight color change at $<900^{\circ}C$, while their colors began to change to black at $1100^{\circ}C$, and became opaque black at $1400^{\circ}C$. After air annealing, there was almost no color change up to $1400^{\circ}C$. Since red and purple CZs showed greater color difference (CD) values than the others, the degree of CD is likely to depend on the original color of the CZ due to the different stabilities of their coloring elements during annealing. Based on our results, it is suggested that annealing in air at $<900^{\circ}C$ is advantageous, and assorted colored CZs can be used for precious metal damascene.

The Optimization of an Operating Dental LED Light Source Module (치과 수술용 LED 광원모듈의 최적화)

  • Jung, Yeon-Oh;Hong, Gi-Tae;Kim, Jae-Yeol;Kim, Sung-Hyun;An, Young-Jin;Han, Jae-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.452-457
    • /
    • 2011
  • The internal temperature of an operating room had to keep within $20^{\circ}C$. However, the doctor who is wearing operating gown and mask caused to rise temperature because of the thermal occurrence of dental LED light source. At first, the surgery environment is getting worse. And then last, it would increase bleeding rate by the expansion of patient's exposured blood vessel. A surgical operator can distribute the patient's tissue through such surgery environment, exactly. It can do accurate surgery. So, it gave to effect that surgical operator's eye condition is getting better and it could keep a mutual assistance system. For this research, we develop the LED dental light source module of high color rendition. It performed simulation for replacing established the method of Halogen lamp and Plazma lamp of light source. We analyzed intensity of illumination and the change of viability by changing the height of light source module.