• 제목/요약/키워드: Exfoliated

검색결과 248건 처리시간 0.029초

Rheological Behavior of Polymer/Layered Silicate Nanocomposites under Uniaxial Extensional Flow

  • Park Jun-Uk;Kim Jeong-Lim;Kim Do-Hoon;Ahn Kyung-Hyun;Lee Seung-Jong;Cho Kwang-Soo
    • Macromolecular Research
    • /
    • 제14권3호
    • /
    • pp.318-323
    • /
    • 2006
  • We investigated the rheological behaviors and orientation of three different types of layered silicate composite systems under external flow: microcomposite, intercalated and exfoliated nanocomposites. Rheological measurements under shear and uniaxial extensional flows, two-dimensional, small-angle X-ray scattering and transmission electron microscopy were conducted to investigate the properties, as well as nano- and micro-structural changes, of polymer/layered silicate nanocomposites. The preferred orientation of the silicate layers to the flow direction was observed under uniaxial extensional flow for both intercalated and exfoliated systems, while the strain hardening behavior was observed only in the exfoliated systems. The degree of compatibility between the polymer matrix and clay determined the microstructure of polymer/clay composites, strain hardening behavior and spatial orientation of the clays under extensional flow.

근로자의 뇨중 상피세포에서 32P-postlabeling에 의한 발암물질의 DNA adducts측정방법에 대한 연구 (Study on Measurement of Carcinogen-DNA adducts in exfoliated urothelial cells among workers by 32P-postlabelling methods)

  • 이진헌;노재훈;그린 탈라스카
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.1-17
    • /
    • 2000
  • Carcinogen-DNA adduct analysis has potential for biomonitoring the earliest effects of exposure to many chemical carcinogens. They are the covalent reaction products of electrophiles and nucleophilic sites on DNA and the initial damage to DNA induced by many carcinogens. So many researchers begin to use them as biomarker for monitoring the earliest exposure of carcinogens and develop the effective analytical techniques about them. Randerath, Gupta and coworkers(1981, 1982) has also developed a $^{32}P$-postlabelling method as one among them. A major project for biomonitoring workers with carcinogen-DNA adducts is to develop non-invasive samples instead of tissues of target organs such as baldder and lung. This study use the exfoliated urothelial cells in urine for examine benzidine-DNA adducts. The content of exfoliated urothelial cells is not enough to significantly measure DNA content with spectrophotometer, and require the another way. So firstly washing the collected cells with PBS and 70% ethanol and centrifuge them for removing the crystals in urine, which block the isolation of DNA adducts. And then, measure the total nucleotide after $^{32}P$-postlabelling for calculating RAL. $[{\gamma}-^{32}P]ATP$ using for $^{32}P$-postlabelling, can synthesize with $[^{32}P]H_3PO_4$, and reagent and enzyme mixture (RM, EM), which is very economic in case of requiring a lot of them. Chromatography was composed of two steps. First step was to separate adduct ones from unadducted nucleotide, and secondary step was separate each adduct, which were performed with 4 kinds of solvents and different directions on TLC. With this procedure, we measure the DNA adducts in exfoliated urothelial cells of workers who were employed in benzidine and benzidine-dye company. RAL of adducts were $89.0{\times}10^7$ and $57.0{\times}10^7$ in them. In conclusion, we can significantly measure the DNA adduct in exfoliated urothelial cells by using the above $^{32}P$-postlabelling procedures, and use them to be biomonitoring workers who exposed carcinogens.

  • PDF

A New Porous Carbon via an Exfoliation of n-Octylammonium Tetrachloroferrate(III)-Graphite Intercalation Complex

  • 권채원;김동훈;최진호
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권10호
    • /
    • pp.1113-1116
    • /
    • 1998
  • A new graphite intercalation compound (GIC), n-octylammonium tetrachlorofeffate(Ⅲ)-graphite, has been derived from well-known ferric chloride graphite intercalation compound. X-ray diffration study shows that the basal spacing of this new GIC is 20.8 Å. In order to investigate the local geometry around the iron atom in the graphite layers, X-ray absorption spectroscopy experiments were performed. The first discharge capacity of its exfoliated form is found to be 862 mAh/g, which is more than double the value of pristine graphite (384 mAh/g). Such a drastic increase implies that the exfoliated graphite is a promising electrode material.

이산화바나듐 나노구조물의 성장에서 그래핀 기판의 영향에 관한 연구 (A Study on the Effect of Graphene Substrate for Growth of Vanadium Dioxide Nanostructures)

  • 김기출
    • 융합정보논문지
    • /
    • 제8권5호
    • /
    • pp.95-100
    • /
    • 2018
  • 금속 산화물/그래핀 형태의 복합 나노소재는 높은 전기용량을 갖는 2차 전지의 전극용 소재 또는 고감도 가스 센서의 감지물질 등으로 활용되는 매우 유용한 기능성 소재이다. 본 논문에서는 열 화학기상증착(CVD, Chemical Vapor Deposition)으로 Cu Foil 위에 대면적으로 합성된 CVD 그래핀 및 고정렬 열분해 흑연(HOPG, Highly Oriented Pyrolytic Graphite)으로부터 기계적으로 박리된 그래핀 기판 위에 이산화바나듐($VO_2$) 나노구조물을 기상수송방법으로 직접 성장시키는 연구를 수행하였다. 연구결과 CVD 그래핀 기판의 경우, 그래핀 결정 경계에서 상대적으로 많이 존재하는 기능기들이 $VO_2$ 나노구조물에서 핵형성의 씨앗으로 작용하는 것이 확인되었다. 반면에 HOPG에서 기계적으로 박리된 그래핀 나노시트 표면에는 기능기가 균일하게 분포하기 때문에, 2차원과 3차원 형태로 $VO_2$ 나노구조물이 성장되었다. 이러한 연구결과는 고기능성 $VO_2$/그래핀 나노복합소재를 이용하여 높은 전기용량을 갖는 2차 전지 전극소재 및 고감도 가스 센서의 감지물질 합성에 유용하게 활용될 것으로 전망된다.

Polyvilylidenefluoride-based Nanocomposite Films Induced-by Exfoliated Boron Nitride Nanosheets with Controlled Orientation

  • Cho, Hong-Baek;Nakayama, Tadachika;Jeong, DaeYong;Tanaka, Satoshi;Suematsu, Hisayuki;Niihara, Koichi;Choa, Yong-Ho
    • Composites Research
    • /
    • 제28권5호
    • /
    • pp.270-276
    • /
    • 2015
  • Polyvinylidene fluoride (PVDF)-based nanocomposites are fabricated by incorporation of boron nitride (BN) nanosheets with anisotropic orientation for a potential high thermal conducting ferroelectric materials. The PVDF is dissolved in dimethylformamide (DMF) and homogeneously mixed with exfoliated BN nanosheets, which is then cast into a polyimide film under application of high magnetic fields (0.45~10 T), where the direction of the filler alignment was controlled. The BN nanosheets are exfoliated by a mixed way of solvothermal method and ultrasonication prior to incorporation into the PVDF-based polymer suspension. X-ray diffraction, scanning electron microscope and thermal diffusivity are measured for the characterization of the polymer nanocomposites. Analysis shows that BN nanosheets are exfoliated into the fewer layers, whose basal planes are oriented either perpendicular or parallel to the composite surfaces without necessitating the surface modification induced by high magnetic fields. Moreover, the nanocomposites show a dramatic thermal diffusivity enhancement of 1056% by BN nanosheets with perpendicular orientation in comparison with the pristine PVDF at 10 vol % of BN, which relies on the degree of filler orientation. The mechanism for the magnetic field-induced orientation of BN and enhancement of thermal property of PVDF-based composites by the BN assembly are elucidated.

Dedicated preparation for in situ transmission electron microscope tensile testing of exfoliated graphene

  • Kim, Kangsik;Yoon, Jong Chan;Kim, Jaemin;Kim, Jung Hwa;Lee, Suk Woo;Yoon, Aram;Lee, Zonghoon
    • Applied Microscopy
    • /
    • 제49권
    • /
    • pp.3.1-3.7
    • /
    • 2019
  • Graphene, which is one of the most promising materials for its state-of-the-art applications, has received extensive attention because of its superior mechanical properties. However, there is little experimental evidence related to the mechanical properties of graphene at the atomic level because of the challenges associated with transferring atomically-thin two-dimensional (2D) materials onto microelectromechanical systems (MEMS) devices. In this study, we show successful dry transfer with a gel material of a stable, clean, and free-standing exfoliated graphene film onto a push-to-pull (PTP) device, which is a MEMS device used for uniaxial tensile testing in in situ transmission electron microscopy (TEM). Through the results of optical microscopy, Raman spectroscopy, and TEM, we demonstrate high quality exfoliated graphene on the PTP device. Finally, the stress-strain results corresponding to propagating cracks in folded graphene were simultaneously obtained during the tensile tests in TEM. The zigzag and armchair edges of graphene confirmed that the fracture occurred in association with the hexagonal lattice structure of graphene while the tensile testing. In the wake of the results, we envision the dedicated preparation and in situ TEM tensile experiments advance the understanding of the relationship between the mechanical properties and structural characteristics of 2D materials.

Mechanical and Thermal Behavior of Polyamide-6/Clay Nanocomposite Using Continuum-based Micromechanical Modeling

  • Weon, Jong-Il
    • Macromolecular Research
    • /
    • 제17권10호
    • /
    • pp.797-806
    • /
    • 2009
  • The mechanical and thermal behaviors of polyamide-6/clay nanocomposites were studied using the continuum-based, micromechanical models such as Mori-Tanaka, Halpin-Tsai and shear lag. Mechanic-based model prediction provides a better understanding regarding the dependence of the nanocomposites' reinforcement efficiency on conventional filler structural parameters such as filler aspect ratio ($\alpha$), filler orientation (S), filler weight fraction (${\Psi}_f$), and filler/matrix stiffness ratio ($E_f/E_m$). For an intercalated and exfoliated nanocomposite, an effective, filler-based, micromechanical model that includes effective filler structural parameters, the number of platelets per stack (n) and the silicate inter-layer spacing ($d_{001}$), is proposed to describe the mesoscopic intercalated filler and the nanoscopic exfoliated filler. The proposed model nicely captures the experimental modulus behaviors for both intercalated and exfoliated nanocomposites. In addition, the model prediction of the heat distortion temperature is examined for nanocomposites with different filler aspect ratio. The predicted heat distortion temperature appears to be reasonable compared to the heat distortion temperature obtained by experimental tests. Based on both the experimental results and model prediction, the reinforcement efficiency and heat resistance of the polyamide-6/clay nanocomposites definitely depend on both conventional (${\alpha},\;S,\;{\Psi}_f,\;E_f/E_m$) and effective (n, $d_{001}$) filler structural parameters.

Phenylethynyl-terminated polyimide, exfoliated graphite nanoplatelets, and the composites: an overview

  • Cho, Donghwan;Drzal, Lawrence T.
    • Carbon letters
    • /
    • 제19권
    • /
    • pp.1-11
    • /
    • 2016
  • In efforts to characterize and understand the properties and processing of phenylethynyl-terminated imide (LaRC PETI-5, simply referred to as PETI-5) oligomers and polymers as a high-temperature sizing material for carbon fiber-reinforced polymer matrix composites, PETI-5 imidization and thermal curing behaviors have been extensively investigated based on the phenylethynyl end-group reaction. These studies are reviewed here. In addition, the use of PETI-5 to enhance interfacial adhesion between carbon fibers and a bismaleimide (BMI) matrix, as well as the dynamic mechanical properties of carbon/BMI composites, are discussed. Reports on the thermal expansion behavior of intercalated graphite flake, and the effects of exfoliated graphite nanoplatelets (xGnP) on the properties of PETI-5 matrix composites are also reviewed. The dynamic mechanical and thermal properties and the electrical resistivity of xGnP/PETI-5 composites are characterized. The effect of liquid rubber amine-terminated poly(butadiene-co-acrylonitrile) (ATBN)-coated xGnP particles incorporated into epoxy resin on the toughness of xGnP/epoxy composites is examined in terms of its impact on Izod strength. This paper provides an extensive overview from fundamental studies on PETI-5 and xGnP, as well as applied studies on relevant composite materials.

Non-invasive Biological Monitoring of DNA Adducts Formed at Workers Handling 3,3-Dichlorobenzidine(DCB) by Using GC/MS

  • Lee, Jin-Heon
    • 한국환경보건학회지
    • /
    • 제29권4호
    • /
    • pp.21-26
    • /
    • 2003
  • We examine the metabolites(DCB and acetyl DCB) extracted from exfoliated urothelial cells of 33 workers who employed DCB-handling industries. The characteristics of workers submitted urine, whose age, working years and smoking persons were 41.9$\pm$11.1, 8.7$\pm$5.5 and 25(32.0%), respectively. DNA adduct was isolated from the exfoliated urothelial cells by applying $^{32}$ p-postlabeling procedure. Metabolites(DCB and acetyl DCB) were extracted from DNA adducts by hydrolyzing and N-glycosylase. Concentrations of DCB and acetyl DCB were 28.6$\pm$5.25 ng/g DNA, and 17.0$\pm$3.73 ng/g DNA, respectively. The regression between DCB level and exposure years of workers is y = 1.668 + 2.588x(p = 0.005, $r^2$= 0.394). The regression between acetyl DCB level and exposure years of workers is y = 8.071 + 1.325x(p = 0.076, $r^2$= 0.222). Smoking workers are significantly higher than non-smoking workers on DCB and acetyl DCB level(p = 0.065 and 0.021, respectively). DCB level was 33.9$\pm$7.14 ng/g DNA on smokers, and 23.1$\pm$9.97 ng/g DNA on non-smokers. Acetyl DCB was 25.1$\pm$5.27 ng/g DNA on smokers, and 8.92$\pm$7.22 ng/g DNA on non-smokers.

Preparation of poly(methyl methacrylate)/clay nanocomposites by microwaveassisted in-situ radical polymerization

  • Jeong, Ji-Won;Kim, Dong-Hyun;Jang, Jae-Ho;Lee, Jung-Taek;Yoo, Kyung-Hyeon;Yoon, Seog-Young
    • 한국결정성장학회지
    • /
    • 제29권1호
    • /
    • pp.19-23
    • /
    • 2019
  • The PMMA (polymethyl methacrylate)/clay nanocomposites were synthesized by in situ radical polymerizations with different clay contents (3 and 7 wt%) using microwave heating. The nanostructure, optical, and thermal properties of the synthesized PMMA/clay nanocomposites were measured by XRD, TEM, AFM, UV-vis, and TGA. It was found that the intercalated- or exfoliated structure of PMMA/clay nanocomposites was strongly dependent on the content of clay. Thus, the imposition of microwave-assisted polymerization facilitated a delamination process of layered silicates to achieve exfoliation state of interlayer distance. The PMMA/3 wt% C10A nanocomposite with well-dispersed and exfoliated clay nano-layers showed the good optical transparency similar to pure PMMA in this study. The thermal decomposition rates of the PMMA/clay nanocomposites become to be lower compared to that of the pure PMMA, indicating the intercalated- or exfoliated inorganic silicate has high thermal stability. A possible reason is that the thermally segmental motion of PMMA polymer into inorganic silicate interlayer spacing has increased the thermal stability of the PMMA/clay nanocomposites.