• Title/Summary/Keyword: Energy-saving plan

Search Result 128, Processing Time 0.027 seconds

A Study on Development for ESCO MRV Plan and Result Reporting Outlines to ESCO Energy Conservation Business (ESCO 에너지절약 MRV 계획서 및 결과서 표준양식 개발방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • This paper aims to create standard forms of MRV plan and report, used when policy funds are applied in accordance with ESCO regulations, when energy savings are measured (the savings would be generated as energy users and ESCOs signed the contract of guarantee for energy savings, and energy saving facilities are installed following the contract). To fully reflect the goals and effects of the installation of energy saving facilities, MRV plans and reports will be completed for the purposes of measuring, verifying, and reporting if the goals of energy savings have been achieved successfully. In this paper, the forms of MRV plans and reports were developed with the detailed descriptions for each form and instructions of completion. Based on the developed forms of MRV plans and reports, future studies need to developed guidelines to explain how to fill out these forms considering the application cases by ESCO technology and facility.

Evaluation on Utilizing Systems of Incineration Heat as Resource cycling Type (자원순환형 소각열 이용시스템에 관한 평가)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.503-510
    • /
    • 2003
  • How to plan the energy system is one of the keys f3r constructing the Environment -Friendly City. for this reason, a great number of surveys for utilizing unused energy have conducted by a planner. In regard to unused energy, the heat from incineration plants classify as a unused energy having high-exergy-energy. From this point of view, It is studied about the plant systems providing heat to district heating & cooling(D.H.C) and producing electric power. It is divided four system models as system I (10K [kgf/cm$^2$) vapor as outlet of boiler, supply far 10K vapor and return to 60$^{\circ}C$ as supply condition of district heating), system II (30 K vapor as outlet of boiler, supply for 5t vapor and return to 60f as supply condition of district heating), system 111 (30 K vapor as outlet of boiler, supply for 85$^{\circ}C$ hot water and return to 60$^{\circ}C$ as supply condition of district heating), system IV (30 K vapor as outlet of boiler, supply for 47$^{\circ}C$ hot water and return to 40t as supply condition of district heating). The results from the upper condition of four system, System II got a proper on economical benefits and system IV calculated as benefiting on energy saving effects, and suggest indifference curve as the total evaluation method of both economical benefits and energy saving.

A Study on Application of the Building Energy Management System(BEMS) for Korean Small or Medium Buildings (국내 중소규모 건축물의 에너지관리시스템 적용방안에 관한 연구)

  • Byun, Jeong-Yoon;Kim, Ju-Hyung;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.159-160
    • /
    • 2011
  • Recently there are many efforts for saving energy in building. therefore Building energy management systems(BEMS) are expected to a reduction energy cost. BEMS has many benefits which could switch plant on and off automatically. Also It optimize plan operation and services, monitor plant status and environmental conditions and to provide energy analysis and management information. In these days, many public buildings are applied BEMS but there are few studies about application of small or medium buildings. Therefore, in this study, we will find how to apply BEMS in small or medium buildings.

  • PDF

Construction Equipment Fleet Optimization for Saving Fuel Consumption (에너지 절감을 위한 건설장비 조합 최적화 방법 연구)

  • Yi, Chang-Yong;Lee, Hong-Chul;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

A Survey on the M&V to guarantee the energy saving performance of ESCO (ESCO 에너지절약 M&V 방법의 선택 및 적용방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.123-129
    • /
    • 2014
  • ESCO industry should guarantee the energy saving performance with M&V such as developed countries. The application of the ESCO M&V is a necessary condition on energy saving performance. This study recommends a goal, direction, and order of application and suggests selection of M&V between option A, option B, option C, option D by energy conservation technology in Korea, with reference to the examples from IPMVP and applied in US and Japan. In the future, it is needed to study on the guideline for plan report and result report of M&V based on a goal, direction, and selection of M&V option.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

The Evaluation of Energy Saving using Ultrathin Heat Insulation in Railway Electrification Substation (철도전기실의 초박형 액체단열재 적용을 통한 에너지 절감효과)

  • Kim, Hyungchul;Jang, Junghoon;Shin, Sungkwon;Park, Yongsub;Kim, Sangam;Kim, Hyeong Rae;Hyun, Byungsoo;Kim, Jinho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.171-175
    • /
    • 2015
  • In this paper, because of global environmental problems such as energy shortage and abnormal climate, green energy development and energy saving technology development is being magnified. Heat insulation, the most basic and traditional energy saving method, is highly expected. Especially, simple and advanced heat insulation technique based on Nano material is promising future technology. The railway system also requires heat insulation. Especially, traditional heat insulator such as glass wool has been adopted frequently to rolling stock. The heat insulator is also adopted in general railway service buildings. Take account of cost-effective heat blocking performance, the heat insulator shall be adopted in diverse fields such as electric power, railroad, signal and communication. The only and direct solution for this problem is installing heat insulator with outstanding endurance, corrosion resistance and heat resistance to block outer heat Upgrading heat specification of equipment can be a solution, but since price and maintenance cost rise severely, this plan might be incongruous. In this research, energy saving effect of ultrathin heat insulator film was demonstrated by installing the film on roof of electrical room.

A Proposal for Partial Automation Preparation System of BIM-based Energy Conservation Plan - Case Study on Automation Process Using BIM Software and Excel VBA - (BIM기반 에너지절약계획서 건축부문 부분자동화 작성 시스템 제안 - BIM 소프트웨어와 EXCEL VBA를 이용한 자동화과정을 중심으로 -)

  • Ryu, Jea-Ho;Hwang, Jong-Min;Kim, Sol-Yee;Seo, Hwa-Yeong;Lee, Ji-Hyun
    • Journal of KIBIM
    • /
    • v.12 no.2
    • /
    • pp.49-59
    • /
    • 2022
  • The main idea of this study is to propose a BIM-based automation system drawing up a report of energy conservation plan in the architecture division. In order to obtain a building permit, an energy conservation plan must be prepared for buildings with a total floor area of 500m2 or more under the current law. Currently, it is adopted as a general method to complete a report by obtaining data and drawings necessary for an energy conservation plan through manual work and input them directly into the verification system. This method takes a lot of effort and time in the design phase which ultimately increases the initial cost of the business, including the services of companies specialized in the environmental field. However, in preparation for mandatory BIM work process in the future, it is necessary to introduce BIM-based automatic creation system that has an advantage for shortening the whole process to enable rapid permission of energy-saving designs for buildings. There may be many methods of automation, but this study introduces how to build an application using Dynamo of Revit, in terms of utilizing BIM, and write an energy conservation plan by automatic completion of report through Dynamo and Excel's VBA algorithm, which can save time and cost in preparing the report of energy conservation plan compared with the manual process. Also we have insisted that the digital transformation of architectural process is a necessary for an efficient use of our automation system in the current energy conservation plan workflow.

A Study on Design for Energy-saving Based on Analysis of Current Situation in School Facilities (학교시설 현황분석을 통한 에너지절약설계 개선방향 연구)

  • Meang, Joon-Ho;Kim, Sung-Joong;Lee, Seung-Min;Ko, Hyun-Su
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • We suggest improvement direction of energy-saving design based on analysis of current situation in school facilities. School facilities have large area among public buildings. While the number of students is decreasing, the number of school and energy consumption is increasing year after year. School facilities have excellent heat insulation property, but it requires further examination about excessive heat insulation plan. School facilities are using gas heat pump actively for cooling and heating, but has difference in use ratio of ground source heat pump by region. Thus School facilities requires active using of ground source heat pump and BIPV(Building Integrated Photovoltaic System).

A Research on Energy Reduction Effect of Cogeneration System of Apartment Houses (공동주택 열병합발전시스템도입에 의한 에너지 절감효과에 관한 연구)

  • Jeon, Min-Kyung;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.484-487
    • /
    • 2006
  • Today, the age of high oil prices is continued, due to the energy demand is on the increase and human principlal energy sorce, fossil fuel. As an alternative plan of energy saving, co-generation system that produces power and thermal energy at the same time has actively developed. In 1960s, co-generation system was introduced to Korea and since 2000 it has diffused throughout the apartment house. Therefore, objectives of this study are to analyze the energy reduction effects in the region 4 apartment houses of Daegu and Kyungbuk regionand set up a plan for its expansion in the future.

  • PDF