• 제목/요약/키워드: Energy detector

검색결과 899건 처리시간 0.028초

Application of CR-39 Microfilm for Rapid Discrimination Between Alpha-Particle Sources

  • Dwaikat, Nidal;Al-Karmi, Anan M.
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.881-885
    • /
    • 2017
  • This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.

Li drifted Ge 검출기에 관해서 (For the Li Drifted Germanium Detector)

  • 함창식
    • 대한전자공학회논문지
    • /
    • 제4권2호
    • /
    • pp.16-21
    • /
    • 1967
  • 이 보고는 처음에 Li drifted Ge 검출기에 관해서 이 Li drifted Ge 검출기에 의한 열중성자로부터의 Cl(n, r) 반응에서 생기는 r선 스텍트로를 보여준다. 이 Li drifted Ge 검출기의 에너지 분해능은 의 122KeV에서 4.5KeV, 의 1333KeV에서 10KeV이다.

  • PDF

Linear-Quadratic Detectors for Spectrum Sensing

  • Biglieri, Ezio;Lops, Marco
    • Journal of Communications and Networks
    • /
    • 제16권5호
    • /
    • pp.485-492
    • /
    • 2014
  • Spectrum sensing for cognitive-radio applications may use a matched-filter detector (in the presence of full knowledge of the signal that may be transmitted by the primary user) or an energy detector (when that knowledge is missing). An intermediate situation occurs when the primary signal is imperfectly known, in which case we advocate the use of a linear-quadratic detector. We show how this detector can be designed by maximizing its deflection, and, using moment-bound theory, we examine its robustness to the variations of the actual probability distribution of the inaccurately known primary signal.

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

비선형 에너지 추적기를 중첩 사용한 근접된 톤 신호의 검출 (A Tone Detector USing Cascaded Nonlinear Energy Trackers)

  • 황성수
    • 한국통신학회논문지
    • /
    • 제25권9B호
    • /
    • pp.1563-1569
    • /
    • 2000
  • 주파수 영역에서 근접한 톤 신호에 대해서 Teager-Kaiser 알고리즘 이라고 알려진 비선형 에너지 추적기를 이용한 검출 방식이 제안된 바 있으나 사용되는 필터 설계에 따라 검출 성능 및 속도가 좌우된다. 본 논문에서는 두개의 비선형 에너지 추적기를 직렬 연결한 구조를 이용하여 주파수 영역에서 근접한 톤 신호를 보다 효율적으로 검출하는 방식을 제안한다. 분석적으로 설계된 검출기의 정검출 및 오검출 성능을 모의 실험을 통하여 검증하고, 기존에 제안된 방식과 비교한다. 제안된 방식은 기존 방식에 비해 복잡도가 개선되고 검출 시간을 줄일 수 있다.

  • PDF

Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging

  • Jan-Peter Grunz;Henner Huflage
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.662-672
    • /
    • 2024
  • Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.

환경방사선감시기의 NaI(Tl) 검출기를 이용한 조사선량률 결정방법 (Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation Monitor)

  • 지영용;이완로;최상도;정근호;강문자;최근식
    • 방사성폐기물학회지
    • /
    • 제11권3호
    • /
    • pp.245-251
    • /
    • 2013
  • NaI(Tl) 섬광검출기로 측정한 에너지 스펙트럼으로부터 공간 감마 선량률을 계산하기 위하여 에너지밴드 방법과 G-factor 방법의 결과를 비교 검토하였다. 먼저 한국원자력연구원 내 운영 중인 환경방사선감시기 EFRD 3300에 장착된 3"${\Phi}X3$" NaI(Tl) 검출기의 G-factor를 MCNP 모델링을 통하여 입사 방사선의 방향에 따라 각각 구하였으며, 이로부터 계산된 선량률과 에너지밴드 방법으로 계산된 결과의 차이를 비교 검토함으로써 EFRD 3300에 적용 가능한 최적의 G-factor 값을 유도하였다. 그리고 EFRD 3300 방사선감시기가 운영되고 있는 지역 주변에 위치한 HPIC 방사선감시기의 선량률과 비교 검토를 수행하였으며, 3"${\Phi}X3$" NaI(Tl) 검출기 기반의 EFRD 3300에서 $7.7{\mu}R/h$의 측정값을 얻어 약 $3{\mu}R/h$ 정도의 차이를 보였다. 일반적으로 HPIC 방사선감시기는 고에너지 우주방사선량도 측정할 수 있는 것으로 알려져 있으므로, 이 차이는 3"${\Phi}X3$" NaI 계측기로 측정되지 못하는 고에너지 영역의 우주방사선에 의한 영향으로 평가할 수 있었다.

방사선 분포측정용 CsI(Tl) 검출기 설계 및 신호처리에 관한 연구 (The Study of CsI(Tl) Scintillation Detector Design and Signal Processing for the Measurement of the Radiation Distribution)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.778-779
    • /
    • 2016
  • 본 논문에서는 공간상에 분포된 방사선원에 대해 화소단위로 방사선 신호를 탐지하기 위한 섬광 검출기를 설계하고, 탐지신호를 취득하기 위한 모듈을 설계하여 방사선 영상화를 위한 연구를 수행하였다. 방사선 분포측정을 위해 적용한 검출기는 CsI(Tl) 섬광체와 결합효율이 높은 수광센서로 구성하였으며, 수광센서를 통해 획득된 신호를 처리하기 위해 펄스 신호를 증폭, 성형 한 후 임계치를 기준으로 펄스를 계수하기 위한 장치를 구현하였다. 제작된 검출기의 성능을 검증하기 위해 감마선 교정시설을 이용하여 검출기에 대한 성능 시험을 수행하고 그 결과를 분석하였다. 본 논문의 결과는 제작된 검출기에 방향성을 부여하기 위한 차폐체 및 조사부를 적용한 후 방향을 이동시켜 개별적인 영역의 값을 2차원 적으로 나타냄으로써 선원의 분포측정을 위한 기초자료로 활용될 것이다.

  • PDF

Radiation Damage of SiC Detector Irradiated by High Dose Gamma Rays

  • Kim, Yong-Kyun;Kang, Sang-Mook;Park, Se-Hwan;Ha, Jang-Ho;Hwang, Jong-Sun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.87-90
    • /
    • 2006
  • Two SiC radiation detector samples were irradiated by Co-60 gamma rays. The irradiation was performed with dose rates of 5 kGy/hour and 15 kGy/hour for 8 hours, respectively. Metal/semiconductor contacts on the surface were fabricated by using a thermal evaporator in a high vacuum condition. The SiC detectors have metal contacts of Au(2000 ${\AA}$)/Ni(300 ${\AA}$) at Si-face and of Au(2000 ${\AA}$)/Ti(300 ${\AA}$) at C-face. I-V characteristics of the SiC semiconductor were measured by using the Keithley 4200-SCS parameter analyzer with voltage sources included. From the I-V curve, we analyzed the Schottky barrier heights(SBHs) on the basis of the thermionic emission theory. As a result, the 6H-SiC semiconductor showed- similar Schottky barrier heights independent to the dose rates of the irradiation with Co-60 gamma rays.

  • PDF