• 제목/요약/키워드: Electrostatic discharge

검색결과 262건 처리시간 0.025초

전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구 (Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution)

  • 박형기;최충석
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

사파이어 기판을 사용한 AlGaN/GaN 고 전자이동도 트랜지스터의 정전기 방전 효과 (Eletrostatic Discharge Effects on AlGaN/GaN High Electron Mobility Transistor on Sapphire Substrate)

  • 하민우;이승철;한민구;최영환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.109-113
    • /
    • 2005
  • It has been reported that the failure phenomenon and variation of electrical characteristic due to the effect of electrostatic discharge(ESD) in silicon devices. But we had fess reports about the phenomenon due to the ESD in the compound semiconductors. So there are a lot of difficulty to the phenomenon analysis and to select the protection method of main circuits or the devices. It has not been reported that the relation between the ESD stress and GaN devices, which is remarkable to apply the operation in high temperature and high voltage due to the superior material characteristic. We studied that the characteristic variation of the AlGaN/GaN HEMT current, the leakage current, the transconductance(gm) and the failure phenomenon of device due to the ESD stress. We have applied the ESD stress by transmission line pulse(TLP) method, which is widely used in ESD stress experiments, and observed the variation of the electrical characteristic before and after applying the ESD stress. The on-current trended to increase after applying the ESD stress. The leakage current and transconductance were changed slightly. The failure point of device was mainly located in middle and edge sides of the gate, was considered the increase of temperature due to a leakage current. The GaN devices have poor thermal characteristic due to usage of the sapphire substrate, so it have been shown to easily fail at low voltage compared to the conventional GaAs devices.

Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger

  • Intra, Panich;Yawootti, Artit;Vinitketkumnuen, Usanee;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.556-562
    • /
    • 2011
  • In the present study, a simple corona-wire charger for unipolar diffusion charging of aerosol particles is designed, constructed, and characterized. Experimental characterizations of the electrostatic discharge in terms of current-voltage relationships of positive and negative coronas of the corona-wire charger are also presented and discussed. The charging current and ion concentration in the charging zone increased monotonically with corona voltage. The negative corona showed higher current than the positive corona. At the same corona voltages, the current in the discharge zone is about 600 times larger than the charging current. The ion number concentrations ranged within approximately $5.0{\times}10^{10}$ to $1.24{\times}10^{16}$ and $4.5{\times}10^{12}$ to $2{\times}10^{16}$ ions/$m^3$ in the discharge and charging zones, respectively. A numerical model is used to predict the behavior of the electric potential lines. Numerical results of ion penetration through the inner electrode are in good agreement with the experimental results.

Development of Capacitance Measuring Equipment for Electrostatic Precipitator

  • Kim, Seung-Min;Lee, Sung-Jin;Nam, Jung-Han;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.128.2-128
    • /
    • 2001
  • Since pulse energization can improve the performance of Electrostatic Precipitator(ESP) for high resistivity dusts, high voltage micro-pulse generators, 70kV 140usec duration pulses for instance, are commonly developed by LC resonance for most pulse powered ESPs. Consisting of discharge electrodes and collecting electrodes, ESP has its own capacitance like a capacitor. ESP's capacitance affects the LC resonance phenomenon with resonance inductor and capacitor of micro-pulse power supply, engineers should acquire the value of their ESP to design for proper power supply design. In this study, we describe the ESP's capacitance measuring device which has the same topology with our new developed micro-pulse power supply. In this microcontroller based capacitance measuring equipment, ESP's capacitance can be calculated easily through ...

  • PDF

기류형성을 위한 고전압 이온풍 발생장치와 코로나 제어기술에 관한 기초적 연구 (Investigation of the HV Ionic Wind Generator and the Control of Corona Discharge for Air-flow Formation)

  • 이복희;엄주홍;강성만;장근철;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1707-1709
    • /
    • 2002
  • Ionic wind may be produced by DC corona discharges. In this work, the electrical effect has studied to evaluate applicability in fields of electrostatic cooling, ozone generation, electrostatic precipitation, heat transfer, air flow modification, and etc. The ionic wind velocity was measured as a function of the distance of pin to plate and the diameter of punched hole. The pin to punched-plate electrode generates airflow from pin to plate and the flow direction is controlled by the hole size of punched-plate, input voltage and distance between two electrodes. As a consequence, the ionic wind velocity is nearly proportional to the applied voltages and ranges from 1 to 3 m/sec.

  • PDF

NUMERICAL MODELING OF WIRE ELECTROHYDRODYNAMIC FLOW IN A WIRE-PLATE ESP

  • Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • 제11권3호
    • /
    • pp.164-171
    • /
    • 2006
  • Numerical modeling of the flow velocity fields for the near corona wire electrohydrodynamic (EHD) flow was conducted. The steady, two-dimensional momentum equations have been computed for a wire-plate type electrostatic precipitator (ESP). The equations were solved in the conservative finite-difference form on a fine uniform rectilinear grid of sufficient resolution to accurately capture the momentum boundary layers. The numerical procedure for the differential equations was used by SIMPLEST algorithm. The Phoenics (Version 3.5.1) CFD code, coupled with Poisson's electric field, ion transport equations and the momentum equation with electric body force were used for the numerical simulation and the Chen-Kim ${\kappa}-{\varepsilon}$ turbulent model numerical results that an EHD secondary flow was clearly visible in the downstream regions of the corona wire despite the low Reynolds number for the electrode ($Re_{cw}=12.4$). Secondary flow vortices caused by the EHD increases with increasing discharge current or EHD number, hence pressure drop of ESP increases.

배기가스 처리용 양방향 펄스 전원 (Bidirectional pulse generator for removal of flue gas)

  • 박정호;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

E-빔 조사에 의한 폴리머의 공간전하 해석 (Space Charge Analysis in Polymers Irradiated by Electron Beam)

  • 윤주호;최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.309-310
    • /
    • 2007
  • Spacecrafts such as most of commercial satellites that are operating in the geostationary orbit can be subjected to intense irradiation by charged particles. The surface made of dielectric materials can therefore become probable sites for damaging electrostatic discharges. Thanks to a specially equipped chamber, the spatial environment can be reproduced experimentally in the laboratory. In this paper, the behavior of high energy electrons injected in polymers such as PolyMethylMetaAcrylate (PMMA) and Kapton is studied. Results obtained by surface potential technique, pulse-electro acoustic device and a cell based on the split Faraday cup system are analyzed and discussed.

  • PDF

인체에 대전된 정전기 방전에 의해 발생한 급속과도전압의 측정 (Measurements of Fast Transient Voltages due to Human Electrostatic Discharges)

  • 이복희;이동문;강성만;엄주홍;이태룡;이승칠
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.108-116
    • /
    • 2002
  • 본 논문은 인체에 대전된 정전기 방전전압 파형의 측정과 특성 분석에 관한 것으로 정전기 고속과도전압 측정기의 동작원리와 설계기법에 대하에 기술하였다. 여러 가지 실험조건에서 인체에 대전된 전하에 의해 발생한 정전기방전전압의 피크값과 상승시간을 분석하였다. 제안된 전압측정계의 주파수대역은 DC-400[MHz]이다. 각 실험조건에서 정전기 방전전압과 전류의 파형은 거의 비슷하였으며, 크기도 비례적 관계를 나타내었다. 빠른 접근일 때가 느린 접근일 때 보다 빠른 초기상승시간의 정전기방전전압이 나타났다. 인체에 의한 직접 방전전압은 비교적 초기상승시간이 10-30[ns]로 길었으나, 크기는 작았다. 반면에 손에 쥔 금속체를 통한 방전전압은 1~3[ns]의 짧은 상승시간을 가지며 피크값은 매우 크게 나타났다. 결국 정전기 방전전압과 전류 파형은 정전기 방전을 일으키는 접촉물체와 접근속도에 깊은 관계가 있음을 알았으며, 본 연구의 결과는 정전기 장해방지장치의 설계를 위한 기초자료로 활용될 것이다.

PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구 (A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity)

  • 이한얼;이광택;안소희;박예원;이건희;홍기정;박인용;김상복;박대훈;이예완;송동근;김용진;한방우;김학준
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.