• 제목/요약/키워드: Electrical test

검색결과 7,379건 처리시간 0.04초

Testability of Current Testing for Open Faults Undetected by Functional Testing in TTL Combinational Circuits

  • Tsukimoto, Isao;Hashizume, Masaki;Mushiaki, Yukiko;Yotsuyanagi, Hiroyuki;Tamesada, Takeomi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1972-1975
    • /
    • 2002
  • A new test approach based on a supply current test method is proposed for testing open faults in bipolar logic circuits. In the approach, only the open faults are detected by the supply current test method, which are difficult to be detected by functional test methods. The effectiveness of the approach is examined experimentally on open fault detection in TTL combinational circuits. The results shows that higher fault coverage can be established by applying a small number of test input vectors of the supply current test method after test vectors of functional test methods based on stuck-at models.

  • PDF

180kV HVDC 해저케이블 기계적/전기적 특성 평가 (Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System)

  • 김남열;이태호;지봉기;이상진;김정년;전승익;윤희석;정수길;강채홍;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

탄성형 에폭시의 흡습에 따른 전기적인 특성 (Electrical Properties according to Moisture Absorption of Elastomer Epoxy Resin)

  • 박재열;박성희;이강원;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1155-1158
    • /
    • 2003
  • In this paper, we studied on the electrical characteristics of insulation material of elastomer epoxy. As the results of test, properties of epoxy represent differently according to elastomer contents. Also, its permittivity, tan ${\delta}$ and BDV(Break-Down Voltage) strength show big difference when those compare before moisture absorption test and after moisture absorption test. From this test we find results that mush elastomer contents can cause insulation properties to degrade.

  • PDF

Korean vowel recognition in noise using auditory model

  • Shim, Jae-Seong;Lee, Jae-Hyuk;Yoon, Tae-Sung;Beack, Seung-Hwa;Park, Sang-Hui
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.1037-1040
    • /
    • 1988
  • In this study, we performed the recognition test on Korean vowel using peripheral auditory model. In addition, for the purpose of objective comparision, the recognition test is performed by extracting LPC cepstrum coefficients from the same data. And the same speech data are mixed with the Guaussian white noise quantitatively, then we repeated the same test, too. So we verified that this auditory model has a adaptability on noise.

  • PDF

2.6GHz 시험주파수를 이용한 대불선 시험선에서의 LTE-R 망 최적화 (Optimization of LTE-R Network using 2.6GHz Test Frequency in Daebul Test Line)

  • 곽우현;김용규
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1398-1405
    • /
    • 2015
  • Domestic railway communication in Korea has been introduced for mutual communications among control center, operation staffs, and maintenance staffs. It has been mainly used as railway disaster and safety functions from VHF and UHF from 1980’s and TRS-Astro and TRS-Tetra from the 2000’s. Recently for urban railways communications, 18GHz and 2.4GHz ranges have been utilized for image transmissions and control command communications, respectively. This paper analyzes technical development of LTE-R, LTE communication for Railways, that has been designed as a single integrated railway wireless network in order to merge the current various communication systems. In this paper, we present the details of the examination of the LTE-R test-bed using 2.6GHz test frequency in Daebul test line through CW test and optimization test.

전기철도 차량용 견인전동기 시험설비 (Test equipment of traction motor for electric train)

  • 장동욱;박현준;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1103-1104
    • /
    • 2006
  • This paper is described about the test equipment of fraction motor for electric train. This test equipment was able to perform the performance test of traction motor which was operated in Korea. We explain performance and function of test equipment. In order to check the performance of test equipment, we conducted the performance test with 200 kW and 1100 kW traction motor.

  • PDF

Micromirror Array의 Yield 측정을 위한 방법 개발 (Development of automatic yield-test equipment for the Micromirror Array)

  • 조광우;김호성;신형재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2547-2549
    • /
    • 1998
  • Automatic yield-test equipment for micro mirror array using image processing was developed. This computerized test equipment can classify the error states of the micromirrors. The test results are displayed on the monitor as a map which shows the error states and position. It is possible to measure yield and reliability with this test equipment for micromirror array using image processing.

  • PDF

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

차수형 케이블의 수트리 가속실험후 와이블분포 해석 (The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable)

  • 김진국;임장섭;송일관;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-181
    • /
    • 2003
  • For many years, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. This paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Voltage) cable.

  • PDF