• Title/Summary/Keyword: Electrical load

Search Result 6,130, Processing Time 0.028 seconds

Load Forecasting using Hierarchical Clustering Method for Building (계층적 군집분석방법을 활용한 건물 부하의 전력수요예측)

  • Hwang, Hye-Mi;Lee, Sung-Hee;Park, Jong-Bae;Park, Yong-Gi;Son, Sung-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • In recent years, energy supply cases to take advantage of EMS(Energy Management System) are increasing according to high interest of energy efficiency. The important factor for essential and economical EMS operation is the supply and demand plan the hourly power demand of building load using the hierarchical clustering method of variety statistical techniques, and use the real historical data of target load. Also the estimated results of study are obtained the reliability through separate tests of validity.

A Study on Decision-making Criteria in Industrial Sector for Electric Load Aggregation (수요반응자원으로서 산업용 부하의 매집 우선순위 결정 기준에 관한 연구)

  • Kim, Sung-Yul;Kim, Dong-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.946-954
    • /
    • 2016
  • Energy industry is undergoing a paradigm shift in customer participation in the smartgrid. Customers traditionally consume electrical power. But nowadays not only do they generate electricity from private distributed generations, they can participate in demand response programs with their negawatt power which means a theoretical unit of power representing an amount of energy saved. Therefore development of decision-making criteria for electric load aggregation becomes a greater consideration as an amount of energy saved from demand response resources increases. This paper proposes load aggregators' decision-making criteria in the industrial sector where it made up the largest portion in demand response portfolio in order to assure reliability performance for demand response resources.

Allocation Strategies of Controllable Loads for Load Aggregator in Power Market (부하관리사업자의 부하배분 전략)

  • Lee, C.J.;Cho, K.S.;Kim, H.C.;Park, J.B.;Shin, J.R.;Kim, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.630-632
    • /
    • 2003
  • This paper describes allocation strategies of controllable loads for load aggregator in power market with the direct load control (DLC) program, which is carried out the two-way confirmation procedure. So, it is needed to the priority among the controllable loads to perform effectively and quickly the confirmation task. In this paper, allocation strategies for market operator and/or load aggregator are proposed, which are based on the basic load patterns defined in this paper. To verify the soundness of proposed strategies. case study on a sample system is performed.

  • PDF

A Study on Residential Hybrid Distribution System for Reducing Power Conversion Loss (전력 변환 손실 저감을 위한 하이브리드 주거배전시스템)

  • Byen, Byeng-Joo;Seo, Hyun-Uk;Choi, Jung-Muk;Lee, Young-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.413-421
    • /
    • 2013
  • This paper proposes residential hybrid distribution system that can supply AC power and DC power to AC load and DC load at the same time. This hybrid distribution system consists of three parts: bidirectional inverter, step-up converter and step-down converter. Also that is used to supply voltage to home application is classified of AC load and DC load as load characteristics. The performance of proposed hybrid distribution system is validated through the hardware implementation and the experimental results.

Position and Force Control for Two Robots with Application to Load Distribution (두 로보트의 위치 및 힘 제어의 부하분배에 관한 응용)

  • Kim, Kab-Il;Jeon, Hun-Jong;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.414-416
    • /
    • 1992
  • Stability analysis and load distribution problem of two coordinating robots using full dynamic model is studied in this paper. Dynamic models of two robots are combined with the position force control strategy and the Liapunov 2nd method is used for the proof of the stability. This analysis shows that the position and force control of two coordinating robot is always stable. Also, load distribution problem is mentioned with respect to the end-effector forces minimizing joint torques.

  • PDF

Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load (불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법)

  • Lee, Wujong;Jo, Jongmin;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

Development of Industrial Load Control Algorithm for Factory Energy Management System (F-EMS) under Real Time Pricing Environment (실시간요금제하에서 산업용 수용가의 부하제어알고리즘 개발)

  • Jeon, Jeong-Pyo;Jang, Sung-Il;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1627-1636
    • /
    • 2014
  • In real-time electricity price environment, the energy management system can provide the significant advantage to the residential, commercial and industrial customers since it can reduce the electricity charge by controlling the load operation effectively in response to time-varying price. However, the earlier studies for load management mainly focus on the residential and commercial customers except for the industrial customers because most of load operations in industrial sector are intimately related with production schedule. So, it is possible that the inappropriate control of loads in industrial sector causes huge economic loss. In this paper, therefore, we propose load control algorithm for factory energy management system(F-EMS) to achieve not only minimizing the electricity charges but also maintaining production efficiency by considering characteristics of load operation and production schedule. Considering characteristics of load operation and production schedule, the proposed load control algorithm can reflect the various characteristics of specific industrial customer and control their loads within the range that the production efficiency is maintained. Simulation results show that the proposed load control algorithm for F-EMS leads to significant reduction in the electricity charges and peak power in industrial sector.

LDO Regulator with Improved Load Regulation Characteristics and Current Detection Structure (Current Detection 구조 및 향상된 Load Regulation 특성을 가진 LDO 레귤레이터)

  • Kwon, Sang-Wook;Kong, June Ho;Koo, Yong Seo
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.506-510
    • /
    • 2021
  • In this paper, we propose an LDO that improves the load regulation change due to the current detection structure. The proposed LDO regulator adds the proposed current detection circuit to the output stage. Thereby to improve the load regulation of the delta value coming in on the output has a voltage value of an improved load Regulation characteristics than conventional LDO regulator. Using the proposed current detection structure, it was possible to improve the output change according to the change of the load current by about 60%. The proposed circuit has been simulated and verified characteristics by using a Spectre, Virtuoso simulation of Cadence.

A Study on the Seasonal Load Characteristics in 22.9[kV] Bus (22.9[kV] 모선의 계절별 부하특성에 관한 연구)

  • 이종필;임재윤;지평식;김기동;김정훈
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.279-286
    • /
    • 2001
  • A load modeling, micro method, is performed by component load modeling, load composition rate estimation and aggregation of component load model, etc. The load model obtained from this process must be applied to actual load bus to verify it and to get reliable load model. But it is difficult to apply every load bus due to al lot of load buses and complex experiment. This paper proposed the field test method in load bus to verify the load modeling. For appropriate field test, representative load buses are selected by the proposed algorithm considering the composition rate of user category in all load buses. The field tests were performed at selected load buses to obtain load characteristics of bus by time and seasonal without blackout. The results of measurement and analysis are presented in detail.

  • PDF

Research on the Improvement of Convergence Characteristics of the Fast Decoupled Load Flow (고속분할법의 수렴특성 개선에 관한 연구)

  • Lee, In-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • In this paper, we propose useful load flow algorithms called FEDL (fast enhanced decoupled load flow). The proposed load flow method can improve the convergence characteristics particularly when the P-Q coupling becomes significant and the power system operating states deviate from the conditions required for stable convergence of the FDL by reflecting in part the effects of the off-diagonal terms in the Jacobian. In our test with IEEE AEP-30 bus system and RTS-96 73-bus system, it converge even when the fast decoupled load flow (FDL) and its variations keeping load flow matrices constant experience convergence problems. Test results show promising performances of the proposed algorithms in their convergence characteristics both in number of iterations and overall convergence speeds.