• Title/Summary/Keyword: Electrical circuit

Search Result 7,402, Processing Time 0.029 seconds

A Study on the Length of Electrical Separation Joint in AF Track Circuit (AF궤도회로에서 전기적 절연구간의 길이에 대한 연구)

  • Lee, Myung-Chul;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.70-75
    • /
    • 2013
  • The electrical separation joint as a filter circuit distributes the track circuit frequency. The electrical separation joint is classified into the interval where reinforcing bars are insulated and not insulated through the length of track circuit. In case of incorrectly setting up the length of electrical separation joint, the amplitude of current on the track circuit is not over standard current which is the standard of current on the track circuit and it effects on the close frequency on track circuit. Then, it makes an accident or makes a train not receive information for train control. In this paper, the electrical separation joint model is suggested and parameters are numerically calculated in the model. Moreover, the length of electrical separation joint is analyzed and is demonstrated by uisng Matlab and PSpice program.

An Improved Distributed Equivalent Circuit Modeling for RF Components by Real-Coefficient AFS Technique

  • Kim, Koon-Tae;Ko, Jae-Hyeong;Paek, Hyun;Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.408-413
    • /
    • 2011
  • In this paper, a real-coefficient approach to Adaptive Frequency Sampling (AFS) technique is developed for efficient equivalent circuit modeling of RF components. This proposed method is advantageous than the vector fitting technique and the conventional AFS method in terms of fewer samples leading to a lower order of a rational function on a given data and to a direct conversion to an equivalent circuit for PSPICE(Personal Simulation Program with Integrated Circuit Emphsis) simulation, respectively. To validate the proposed method, the distributed equivalent circuit of a presented multi-layered RF low-pass filter is obtained using the proposed real-coefficient AFS, and then comparisons with EM simulation and circuit simulation for the device under consideration are achieved.

Fractional-order LβCα Low-Pass Filter Circuit

  • Zhou, Rui;Zhang, Run-Fan;Chen, Di-Yi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1597-1609
    • /
    • 2015
  • This paper introduces the fundamentals of the conventional LC low-pass filter circuit in the fractional domain. First, we study the new fundamentals of fractional-order LC low-pass filter circuit including the pure real angular frequency, the pure imaginary angular frequency and the short circuit angular frequency. Moreover, sensitivity analysis of the impedance characteristics and phase characteristics of the LC low-pass filter circuit with respect to the system variables is studied in detail, which shows the greater flexibility of the fractional-order filter circuit in designs. Furthermore, from the filtering property perspective, we systematically investigate the effects of the system variables (LC, frequency f and fractional orders) on the amplitude-frequency characteristics and phase-frequency characteristics. In addition, the detailed analyses of the cut-off frequency and filter factor are presented. Numerical experimental results are presented to verify the theoretical results introduced in this paper.

Analysis on Fault Current Limiting Characteristics of Flux-Lock Type SFCL Using Magnetic Flux Application Circuit (자기인가회로를 이용한 자속구속형 초전도한류기의 고장전류제한 특성 분석)

  • Go, Ju-Chan;Lim, Seung-Taek;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • In this paper, the fault current limiting characteristics of the flux-lock type SFCL (superconducting fault current limiter) using magnetic application circuit were analyzed. The flux-lock type SFCL has the structure to install the magnetic application circuit, which can increase the resistance of HTSC ($high-T_C$ superconducting element comprising) the SFCL. To analyze the fault current limiting effect of the flux-lock type SFCL through the magnetic flux application circuit, the flux-lock type SFCL either with the magnetic flux circuit or without the magnetic flux circuit was constructed and the fault current limiting characteristics of the SFCL were compared each other through the short-circuit tests.

The Study About Low Voltage Circuit Breaker Mix Method Between IEC Circuit Breaker and Domestic Circuit Breaker (저압용 IEC 차단기와 국내 차단기 혼용방안에 관한 연구)

  • Jung, Jin-Soo;Kim, Han-Sang;Han, Woon-Ki;Kim, Sun-Gu;Park, Chan-Eom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.905-909
    • /
    • 2012
  • Recent WTO/TBT agreement was adopted by the IEC domestic. For this reason, low voltage electrical equipment was many Confusion arises. Low voltage circuit was also one of these. The case of low voltage circuit, existing domestic circuit breakers and circuit breakers IEC curve differs from the behavior of each other. If low voltage circuit breaker wrong facility, circuit breaker malfunction may occur due to the large property damage. In this paper, to solve these problems domestic circuit breakers and circuit breaker operation IEC curves were analyzed. And, through experiments suggested compatible breaker way.

An Electrical Repair Circuit for Yield Increment of High Density Memory (고집적 메모리의 yield 개선을 위한 전기적 구제회로)

  • 김필중;김종빈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.273-279
    • /
    • 2000
  • Electrical repair method which has replaced laser repair method can replace defective cell by redundancy’s in the redundancy scheme of conventional high density memory. This electrical repair circuit consists of the antifuse program/read/latch circuits, a clock generator a negative voltage generator a power-up pulse circuit a special address mux and etc. The measured program voltage of made antifuses was 7.2~7.5V and the resistance of programmed antifuses was below 500 Ω. The period of clock generator was about 30 ns. The output voltage of a negative voltage generator was about 4.3 V and the current capacity was maximum 825 $mutextrm{A}$. An antifuse was programmed using by the electric potential difference between supply-voltage (3.3 V) and output voltage generator. The output pulse width of a power-up pulse circuit was 30 ns ~ 1$mutextrm{s}$ with the variation of power-up time. The programmed antifuse resistance required below 44 ㏀ from the simulation of antifuse program/read/latch circuit. Therefore the electrical repair circuit behaved safely and the yield of high densitymemory will be increased by using the circuit.

  • PDF

A New Sustaining Driver for AC PDPs with Reduced Sustain Voltage by Half (새로운 유지구동전압 반감형 AC PDP 구동회로)

  • Lim, Seung-Bum;Cho, Pil-Yong;Chae, Soo-Yong;Kang, Kyoung-Woo;Yoo, Jong-Gul;Ko, Jong-Sun;Hong, Sonn-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.452-455
    • /
    • 2005
  • This paper proposes a new sustaining driver for AC PDP(Plasma Display Panel), which improves the performance of conventional circuit with reduced sustain voltage such as TERES(TEchnology of REciprocal Sustainer). In the TERES circuit, the sustain voltage is the half of general sustaining driver and there is no energy recovery circuit. The circuit proposed in his paper has an energy recovery circuit and removes surge currents. Although the energy recovery circuit is added, the number of active switching elements is the same as the TERES circuit. The operations of the proposed circuit are analyzed for each mode and its validity is verified by the simulations using PSpice program.

  • PDF

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF

Short-circuit Protection Circuit Design for SiC MOSFET Using Current Sensing Circuit Based on Rogowski Coil (Rogowski Coil 기반의 전류 센싱 회로를 적용한 SiC MOSFET 단락 보호 회로 설계)

  • Lee, Ju-A;Byun, Jongeun;Ann, Sangjoon;Son, Won-Jin;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.214-221
    • /
    • 2021
  • SiC MOSFETs require a faster and more reliable short-circuit protection circuit than conventional methods due to narrow short-circuit withstand times. Therefore, this research proposes a short-circuit protection circuit using a current-sensing circuit based on Rogowski coil. The method of designing the current-sensing circuit, which is a component of the proposed circuit, is presented first. The integrator and input/output filter that compose the current-sensing circuit are designed to have a wide bandwidth for accurately measuring short-circuit currents with high di/dt. The precision of the designed sensing circuit is verified on a double pulse test (DPT). In addition, the sensing accuracy according to the bandwidth of the filters and the number of turns of the Rogowski coil is analyzed. Next, the entire short-circuit protection circuit with the current-sensing circuit is designed in consideration of the fast short-circuit shutdown time. To verify the performance of this circuit, a short-circuit test is conducted for two cases of short-circuit conditions that can occur in the half-bridge structure. Finally, the short-circuit shutdown time is measured to confirm the suitability of the proposed protection circuit for the SiC MOSFET short-circuit protection.

The short-circuit calculation and circuit breaker selection as IEC standard (IEC규격에 의한 고장전류해석 및 차단기용량선정)

  • Lee, Kyung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.433-436
    • /
    • 2007
  • This paper analyzes how to calculate the three phase short-circuit currents for ac electrical system and select the high & low voltage circuit breaker based on IEC60609, IEC60056 and IEC60947-2 standards. We proposed the multiplying factor considering system time constant and circuit breaker rating to select circuit breaker accurately.

  • PDF