• Title/Summary/Keyword: Electrical burn

Search Result 95, Processing Time 0.031 seconds

Fabrication and Characterization of BSCCO System High-Temperature Superconductor Tube Using Centrifigal Forming Process (원심성형법을 이용한 BSCCO계 고온초전도튜브 제조 및 특성 분석)

  • 박용민;장건익
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.801-804
    • /
    • 2000
  • High-temperature superconductor of Bi-2212 system was fabricated by CFP(Centrifugal Forming Process). To make a uniform specimen slurry was prepared in the ratio of 7:3(powder : binder) and ball milled for 24 hours. Milled slurry was charged into a rotating mold with 450 rpm and dried at room temperature. Then the specimen was performed binder burn-out at 35$0^{\circ}C$ and heated for partial melting to 86$0^{\circ}C$. XRD analysis of most specimens were shown 2212 phase and observed a local plate shped microstructure with a well aligned c-axis direction from SEM images. Measured T$_{c}$(Critical temperature) was about 64 K.K.

  • PDF

Study on Degradation of A/F Sensor (A/F 센서의 열화해석)

  • 권창순;이정호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.101-105
    • /
    • 1994
  • A/F sensor with a sensing and a pumping element, which is made of YSZ(yttria stabilized zirconia) sheets, can be used for the combustion control of lean burn engine. A/F sensor can detect the oxygen partial pressure in more wide range than the other oxygen sensors, such as the limiting current type oxygen sensor and λ-sensor. However this sensor has the disadvantage that the characteristics has been degraded rapidly due to the physical or electrochemical reasons. The blackening phenomenon is known as one of the degradations caused by high voltage biased for oxygen pumping. In this paper, we have studied to analyze the blackening phenomenon by comparing two characteristics between before and after blackening in impedance spectroscopy, and discussed the blackening mechanism.

A Study on Ageing Characteristics of RTV Silicone Coating Materials by Corona Discharge (RTV 실리콘 코팅재의 코로나 방전 열화 특성)

  • 한세원;한동희;조한구
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.359-364
    • /
    • 2003
  • Ageing characteristics of RTV coating materials by corona discharge have been studied. The hydrophobicity recovery of RTV coating materials with 300${\mu}{\textrm}{m}$ thickness was identical with a bulk silicone materials. The RTV coating materials hydrophobicity has been almost lost when its were discharged during 40 seconds by corona discharge of 10㎸, and recovered after about 45 hours. The resistivity of RTV coating materials has not been recovered after 45 hours, though after 80 hours the initiation resistivity value has been recovered up to 95%. There was no critical change of compounds(such as Si and Al) on RTV surfaces by the corona discharge treatment until 100 seconds. In the test of arc erosion, it was seen that the coating sample with silicone rubber as a base material have more longer burn-out time than other samples with FRP or glass base.

A Study on the Self-extinguishing for Aircraft Wire (항공기용 배선의 자가소화성에 관한 연구)

  • Jeong, Duck-Young;Yi, Baeck-Jun;Lee, Jong-Hee
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.13-16
    • /
    • 2011
  • All components such as structure, engine, electrical equipment, wire etc. should have certified qualities and functions for safe flight. The wire like a blood vessel of man is connected with most components and supply a electrical signal or power to them and only certified wire through a lot of tests such as rating, flame resistance, self-extinguishing, protection of EMI etc. must be used in aircraft. In other words, the wire should observe many certification requirements because it is one of the most important components.

Fabrication and Characterization of BSCCO System High-Temperature Superconductor Using Centrifugal Forming Process (원심성형법을 이용한 BSCCO계 고온초전도체 제조 및 특성 분석)

  • 박용민;장건익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.189-192
    • /
    • 2000
  • High-temperature superconductor of Bi-2212 system was fabricated by CFP(centrifugal forming process). To make a uniform specimen slurry was prepared in the ratio of 7:3(powder:binder) and ball milled for 24 hours. Milled slurry was charged into a rotating mold with 450 rpm and dried at room temperature. Then the specimen was performed binder burn-out at 35$0^{\circ}C$ and heated for partial melting to 86$0^{\circ}C$. XRD analysis of most specimens were shown 2212 phase and observed a local plate shaped microstructure with a well aligned c-axis direction from SEM images. T$_{c}$(Critical temperature) of Bi-2212 was 64K.K.

  • PDF

A Experimental Study on the Heat Release Rate to activate Fire Detection Sensor (화재감지 센서 작동시간 및 열방출률에 대한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1358-1361
    • /
    • 2012
  • This paper presents a study on the analysis for activation time and threshold value of heat detection sensor using HRR(Heat Release Rate). And it is represented to quantity of heat to activate heat detection sensor. The experiment is conducted to measure activation time and HRR of fire detection sensor burning alcohol and n-heptane. In order to burn the alcohol and n-heptane using $43.5cm(L){\times}43.5cm(W){\times}5cm(D)$ and $33cm(L){\times}33cm(L){\times}5cm(D)$ steel pan and the quantity of alcohol and n-heptane are 2.5 L and 650 g, respectively. The results show that peak HRR are in case of alcohol 66.13 kW and in case of n-heptane 151.64 kW, respectively. Total heat releases of heat detection sensor are in case of alcohol approximately 20.7 MJ and in case of n-heptane approximately 18 MJ, respectively.

Study on junction temperature characteristics of TO-CAN laser diode for optimized screening tests (접합 온도를 고려한 TO-CAN 레이저 다이오드의 Screening 조건 연구)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.126-129
    • /
    • 2002
  • To extract exact screening conditions of TO-CAN laser diode, junction temperature during screening was investigated. Temperature increase due to thermal resistance was measured and compared with theoretical calculation. Injection current dependence of injection temperature was derived with good agreement with experimental data and used to obtain accurate screening conditions.

Calorie Burn Estimation Algorithm from a Accelerometer using Multiple Regression Analysis (다중회귀분석을 이용한 3축 가속도 센서기반 활동량 추정 방법)

  • Choe, Sun-Taag;Lee, Kyu Feel;Kim, Jun Ho;Cho, We-Duke
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.953-955
    • /
    • 2016
  • 본 논문은 다중 회귀 분석을 이용하여 3축 가속도센서기반의 활동량을 추정하는 방법을 제안한다. 본 연구를 위해 총 59명의 피 실험자가 자체 제작한 활동량계를 착용한 뒤 트레드밀에서 일정한 속도로 걷는/뛰는 동작을 수행한 신호를 수집하였다. 수집한 3축 가속도 신호의 에너지 값에서 사전에 정의한 특징들을 산출한다. 그 다음 각 특징별로 선형, 지수, 로지스틱 회귀 분석을 적용하여 적합도가 높은 특징을 선정한다. 마지막으로 산출된 회귀식들을 사용하여 다중 회귀 분석 방법으로 활동량을 추정한다. 호흡가스 대사 분석기(K4B2)를 착용한 뒤 동일한 방법으로 실험을 수행 하고 제안한 방법과 정확도를 비교한 결과 제안한 방법의 정확도는 86.38 %로 산출되었다. 이는 기존의 Kim 외 3인의 연구결과[1]보다 2.70 %, Actical의 정확도보다 4.31 % 높은 수치이다.

Electrical breakdown free SWCNT thin film transistors on flexible polyimide substrate

  • Park, Jae-Hyeon;Ha, Jeong-Suk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.58-58
    • /
    • 2010
  • Carbon nanotubes (CNTs) have been extensively studied owing to its superior electrical properties, especially high electron mobility, which can be applied to various nano-electronic devices. However, synthesized CNTs have a mixture of metallic and semiconducting tubes so that their separation has been a tremendous obstacle to the practical application in electronic device structures. Among the different separation methods, electrical breakdown process to selectively burn out the metallic tubes has been quite successful though it needs additional process in the fabrication of device structures. Here, we report on the selective but not perfect growth of semiconducting nanotubes via use of diluted ferritin catalyst. SWCNTs were grown on ferritin catalyst, where the concentration of the ferritin solution was changed. In this way, we could fabricate the electrical breakdown free SWCNT thin film transistors on the flexible polyimide (PI) substrate. When we used the ferritin diluted by 1/2000, ~ 60 % of the SWCNT thin film transistors showed a perfect p-type behavior with an on/off current ratio higher than $10^5$ and on-current greater than $10^{-7}$ A. We will also discuss the photo-response of such formed thin film transistors over both visible and UV light.

  • PDF

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF