• 제목/요약/키워드: Electric Charge-discharge

검색결과 241건 처리시간 0.022초

질소가스에 대한 2차원 코로나 방전특성 해석 (Two-dimensional simulation of corona discharge characteristics in nitrogen)

  • 최종대;심재학;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1834-1836
    • /
    • 1997
  • In this study, we simulated the developing process of two-dimensional corona discharge using the fluid method in 760 torr. It was assumed that the transport coefficients of nitrogen gas were only the function of local electric field. Discharge mechanisms considered were a Townsend first ionization and a secondary electron emission. We obtained spatio-temporal distribution of electron and ion by calculating continuity equation using FCT algorithm and calculated an electric field distribution considering a space charge.

  • PDF

예방진단센서가 내장된 옥외용 ECT의 전계분포특성 (The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor)

  • 이한주;조성훈;정의환;윤재훈;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

EPR의 전기특성에 미치는 방사선의 영향 (Effect of the Co$^{60}$ -Rays due to Electric properties of EPR-)

  • 이성일
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 추계학술대회
    • /
    • pp.253-259
    • /
    • 2002
  • The value of charge currnet, discharge current, ${\varepsilon}r^'$,${\varepsilon}r^{'}$ residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated C0$^{60}$$\gamma$ ray 0~38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by C0$^{60}$-$\gamma$- irradiation dose. The charging current and the discharging current of EPR increas, depending on the ratio of degradation. As the irradiatin dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful C0$^{60}$$\gamma$- irradiation dose. The increase of peak in ${\varepsilon}r^{'}$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

에폭시 수지의 전기 특성에 미치는 습도의 영향에 관한 연구 (A study on Effect of humidity on Electric Properties in Epoxy Resin)

  • 이성일;박일규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.303-306
    • /
    • 2001
  • Composite insulating materials used in outdoor high voltage equipment are required to have high electric performance because of the miniaturization. The frequence dependence of the permittivity and the loss tangent have important information. In this paper we describe the frequency dependence of the permittivity and the loss tangent for epoxy resin filled with silica and the influence of filler shape on the dielectric properties. The increment of tan $\delta$ in the low frequency region is caused by the increment of both of the electrical conductivity and the polarization due to the shape of filler and water sbsorbed in and near the interface between the fillers and resins. Result of charge current and discharge measure, electric conduction increased according to voltage.

  • PDF

초고압 $SF_6$가스중의 선구방전기구 (Precursor Discharge Mechanism under EHV in $SF_6$ Gas)

  • 이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 1996
  • The axial discharge at switching operations of EHV $SF_6$ disconnector can lead to the breakdown to the enclosure. Precursor in periphery zone leads to formation of leader over some time delay. Injected charge value depends on electric field and gap geometry. The calculation method for parameters of $SF_6$ insulation for DS in EHV-GIS is suggested by using the new criterion of leader inception in connection with periphery field nearby the boundary of streamer zone.

  • PDF

잠수함 추진용 리튬이온전지 충방전 특성 및 안전성 확보를 위한 실험적 연구 (An Experimental Study on the Charging/Discharging Characteristics and Safety of Lithium-Ion Battery System for Submarine Propulsion)

  • 김범석;손승현;강석중
    • 대한조선학회논문집
    • /
    • 제58권4호
    • /
    • pp.225-233
    • /
    • 2021
  • Conventional submarine propulsion batteries have mainly used lead acid batteries, which have proved relatively safe, but in recent years, research on mounting lithium-ion batteries to improve the underwater operation capability of submarines is underway in advanced countries such as Japan. Korea has world-class technology in the development of electric vehicles and lithium-ion batteries for energy storage, but fire safety accidents continue to occur in electric vehicles and energy storage lithium-ion batteries. In order to mount the lithium-ion battery in a submarine, it is necessary to check the safety as well as whether the performance is improved compared to the lead acid battery. Through the charge/discharge experiment of this lithium-ion battery module unit, it was possible to measure how much performance was improved compared to the lead acid battery. Safety tests were conducted on the lithium-ion battery module assuming that it was mounted on a submarine, and it was confirmed that safety was secured when applied to a submarine. Since many modules are mounted on actual submarines, it has been confirmed that it can be applied to submarine systems by simulating charge/discharge characteristics through Hardware-in-the Loop(HILS). Through the results of this study, the application of lithium-ion batteries to submarines is expected to significantly improve the sustainability of underwater operations.

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

오존발생특성 향상을 위한 강유전성 알루미나 무성방전관의 개발 (Development of Silent Discharge Chamber with Al2O3 Dielectric Pellet to Improve Ozone Generation Characteristics)

  • 곽동주
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.58-64
    • /
    • 2006
  • 최근 탈취, 탈색, 정수처리 및 배연가스의 정화에 많이 이용되고 있는 오존의 효과적인 발생에 많은 관심이 모아지고 있다. 전기 방전에 의한 오존 발생 방법 중 유전체 배리어 방전이 보다 낮은 전력을 소모하며, 또한 저전압 동작이 가능하여 가장 효과적인 것으로 생각되고 있다. 본 연구에서는 오존발생농도 및 에너지효율을 개선하기 위하여 알루미나 유전체 및 알루미나 유전체와 알루미나 비드를 충진한 무성방전관을 제작하여 무성방전특성을 연구하였다. 또한 오존발생특성을 무성방전특성과 연관하여 논하였으며, 특히 방전시 유전체에 축적되는 벽전하 및 소비전력특성의 관점에서 논하였다. 결과, 비드를 가진 방전관의 경우 축적되는 벽전하량은 비드가 없는 방전관에 비하여 약 2.5배 정도였으며, 발생되는 오존농도 및 에너지 수율 또한 개선되었다.

FE Analysis of Plasma Discharge and Sheath Characterization in Dry Etching Reactor

  • Yu, Gwang Jun;Kim, Young Sun;Lee, Dong Yoon;Park, Jae Jun;Lee, Se Hee;Park, Il Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.307-312
    • /
    • 2014
  • We present a full finite element analysis for plasma discharge in etching process of semiconductor circuit. The charge transport equations of hydrodynamic diffusion-drift model and the electric field equation were numerically solved in a fully coupled system by using a standard finite element procedure for transient analysis. The proposed method was applied to a real plasma reactor in order to characterize the plasma sheath that is closely related to the yield of the etching process. Throughout the plasma discharge analysis, the base electrode of reactor was tested and modified for improving the uniformity around the wafer edge. The experiment and numerical results were examined along with SEM data of etching quality. The feasibility and usefulness of the proposed method was shown by both numerical and experimental results.

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.