Effects of the ESD Protection Performance on GPNS(Gate to Primary N+ diffusion Space) Variation in the NSCR_PPS Device (NSCR_PPS 소자에서 게이트와 N+ 확산층 간격의 변화가 정전기 보호성능에 미치는 영향)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.6-11
    • /
    • 2015
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different GPNS(Gate to Primary $N^+$ Diffusion Space) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device with FPW(Full P-Well) structure and non-CPS(Counter Pocket Source) implant shows typical SCR-like characteristics with low on-resistance(Ron), low snapback holding voltage(Vh) and low thermal breakdown voltage(Vtb), which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW(Partial P-Well) structure and optimal CPS implant demonstrate the improved ESD protection performance as a function of GPNS variation. GPNS was a important parameter, which is satisfied design window of ESD protection device.

Design of Electronic Software Distribution Protocol for Software Copyright Protection (소프트웨어 저작권 보호를 위한 전자 소프트웨어 유통 프로토콜의 설계)

  • Kim, Young-Jun;Lee, Sung-Min;Rhee, Yoon-Jung;Park, Nam-Sup;Lee, Byung-Rae;Kim, Tai-Yun
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.4
    • /
    • pp.641-650
    • /
    • 2001
  • In recent years, e-Commerce is very active on the Internet, especially the World Wide Web along with the popularization of Internet using high-speed networks. Especially, Electronic Software Distribution(ESD) is widely being focused as one of the popular researches. However, the existing models of ESD lack substantial illegal copy protection or copyright protection as they have the shortcomings of guaranteeing anonymity of users. This study suggests an ESD protocol that guarantees substantial copyright protection and anonymity based on the Public Key Infrastrncture(PKl). The suggested method does not give the information of a buyer who doesn't want to reveal to a seller, and protects illegal copy and distribution as well. When it happens that illegal copies are in circulation, this method provides a device to trace back its original distributor so that it helps protect the copyright. In addition, it provides more convenient environment to the user by not using the methods of serial number input and extra installation to use.

  • PDF

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Early Detection is Important to Reduce the Economic Burden of Gastric Cancer

  • Kim, Jie-Hyun;Kim, Sung Soo;Lee, Jeong Hoon;Jung, Da Hyun;Cheung, Dae Young;Chung, Woo-Chul;Park, Soo-Heon
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.82-89
    • /
    • 2018
  • Purpose: Early detection of gastric cancer is important to improve prognosis. Early detection enables local treatment, such as endoscopic submucosal dissection (ESD). Therefore, we investigated whether early detection of gastric cancer could reduce healthcare costs by comparison according to stage and treatment modalities. Materials and Methods: Medical care costs were investigated according to tumor stage and initial treatment modality in 1,188 patients newly diagnosed with gastric cancer at 7 medical institutions from December 2011 to June 2012. Total medical care costs during the first-year after diagnosis (total first-year costs) were examined, including the costs of initial treatment, post-initial treatment, and inpatient and outpatient visits. Results: Stage I (75.3%) was the most common cancer stage. ESD was the second most common treatment following surgery. Total first-year costs increased significantly from stages I to IV. The costs of initial treatment and post-initial treatment were lowest in patients with stage I cancer. Among patients with stage I cancer, total first-year costs were significantly lower when treated by ESD; in particular, initial ESD treatment costs were much lower than others. Conclusions: The cost of healthcare has increased significantly with increasing cancer stages. ESD can greatly reduce medical care costs of gastric cancer. Thus, early detection of gastric cancer is important to reduce healthcare costs.

Fault Detection in LDPE Process using Machine Learning Techniques (머신러닝 기법을 활용한 LDPE 공정의 이상 감지)

  • Lee, Changsong;Lee, Kyu-Hwang;Lee, Hokyung
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.224-229
    • /
    • 2020
  • We propose a machine learning-based method for proactively detecting faults in LDPE processes and predicting equipment lifespan. It is important to detect and prevent unexpected faults in chemical processes in order to maximize safety and productivity. Since LDPE process is a high-pressure process up to 3,000 kg/㎠g or more, once ESD occurs, it can result in productivity loss due to increased maintenance periods. By collecting key variables operation data of the process and using unsupervised machine leaning methods, we developed a fault detection model which detected 4 ESDs 2.4 days prior to the occurrence. In addition, it was confirmed that the life expectancy of a hyper compressor can be predicted by using the physically significant key variables.

Analysis of a Novel Elevated Source Drain MOSFET with Reduced Gate-Induced Drain Leakage and High Driving Capability (Gate-Induced Drain Leakage를 줄인 새로운 구조의 고성능 Elevated Source Drain MOSFET에 관한 분석)

  • Kim, Gyeong-Hwan;Choe, Chang-Sun;Kim, Jeong-Tae;Choe, U-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.6
    • /
    • pp.390-397
    • /
    • 2001
  • A novel self-aligned ESD (Elevated Source Drain) MOSFET structure which can effectively reduce the GIDL (Gate-Induced Drain Leakage) current is proposed and analyzed. The proposed ESD structure is characterized by sidewall spacer and recessed-channel depth which are determined by dry-etching process. Elevation of the Source/Drain extension region is realized so that the low-activation effect caused by low-energy ion implantation can be avoided. Unlike the conventional LDD structures, it is shown that the GIDL current of the ESD structure is suppressed without sacrificing the maximum driving capability. The main reason for the reduction of GIDL current Is the decreased electric field at the point of the maximum band-to-band tunneling as the peak electric field is shifted toward the drain side.

  • PDF

Education for Sustainable Development within School Geography: A Proposed Model (학교 지리에서 지속가능발전 교육: 모델 구안)

  • Sim, Kwangtaek;Stoltman, Joseph P.
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.3
    • /
    • pp.466-481
    • /
    • 2013
  • The purpose of this research is to propose a model for education for sustainable development (ESD) within the geography curriculum. The study consists of two parts. The first part discusses the normal view of a model to assess the curriculum, namely the content and the cognitive dimensions. The ESD component necessitates an action program with skills and citizenship considered as the Objective Dimension. The second part of the paper examines the means for adding the Objective Dimension which follows a taking action approach through knowledge, skills, and citizenship that are consistent with ESD goals. The research procedure applied the methodology of the Delphi process. The theoretical model was initially developed by the researchers based on current practices in geography assessment in South Korea and the U.S. The model was tested using the Delphi technique by high school geography teachers and geography education faculty members in both countries who were recognized experts in their field. The research complements the curriculum and instructional activities that have been under way with the United Nations Decade of Education for Sustainable Development (UNDESD). The model may be used to deliberate proposals for building an ESD component into existing assessment practices.

  • PDF

A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique (컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구)

  • Seoung, Youl-Hun;Rhim, Jea-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

Determination of optimal ion implantation conditions to prevent double snapback of high voltage operating DDDNMOS device for ESD protection (고전압 정전기 보호용 DDDNMOS 소자의 더블 스냅백 방지를 위한 최적의 이온주입 조건 결정)

  • Seo, Yong-Jin
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.333-340
    • /
    • 2022
  • Process and device simulations were performed to determine the optimal ion implantation conditions to prevent double snapback of high voltage operating DDDNMOS (double diffused drain N-type MOSFET) device for ESD protection. By examining the effects of HP-Well, N- drift and N+ drain ion implantation on the double snapback and avalanche breakdown voltages, it was possible to prevent double snapback and improve the electrostatic protection performance. If the ion implantation concentration of the N- drift region rather than the HP-Well region is optimally designed, it prevents the transition from the primary on-state to the secondary on-state, so that relatively good ESD protection performance can be obtained. Since the concentration of the N- drift region affects the leakage current and the avalanche breakdown voltage, in the case of a process technology with an operating voltage greater than 30V, a new structure such as DPS or colligation of optimal process conditions can be applied. In this case, improved ESD protection performance can be realized.

The pattern of metachronous recurrence after endoscopic submucosal dissection for gastric adenocarcinoma and dysplasias

  • Sunah Suk;Yeon Joo Seo;Dae Young Cheung;Han Hee Lee;Jin Il Kim;Soo-Heon Park
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.470-478
    • /
    • 2023
  • Background/Aims: Metachronous recurrence incidences and risk factors following endoscopic submucosal dissection (ESD) for gastric adenocarcinoma and dysplasias were investigated. Methods: Retrospective review of electronic medical records of patients who underwent gastric ESD at The Catholic University of Korea, Yeouido St. Mary's Hospital. Results: A total of 190 subjects were enrolled for analysis during the study period. The mean age was 64.4 years and the male sex occupied 73.7%. The mean observation period following ESD was 3.45 years. The annual incidence rate of metachronous gastric neoplasms (MGN) was about 3.96%. The annual incidence rate was 5.36% for the low-grade dysplasia group, 6.47% for the high-grade dysplasia group, and 2.74% for the EGC group. MGN was more frequent in the dysplasia group than in the EGC group (p<0.05). For those with MGN development, the mean time interval from ESD to MGN was 4.1 (±1.8) years. By using the Kaplan-Meier model, the estimated mean MGN free survival time was 9.97 years (95% confidence interval, 8.53-11.40) The histological types of MGN were not related to the primary histology types. Conclusions: MGN following ESD developed in 3.96% annually and MGN was more frequent in the dysplasia group. The histological types of MGN did not correlate with those of primary neoplasm.