Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR  

Kim, Sang-Tae (Department of Radiological Science, Hanlyo University)
Han, Beom-Hui (Department of Radiological Science, Seonam University)
Publication Information
Journal of radiological science and technology / v.33, no.3, 2010 , pp. 173-178 More about this Journal
Abstract
In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.
Keywords
Computed radiography; Digital radiography; Entrance skin dose;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M. Tapiovaara, M. Lakkisto And A. Servomaa, PCXMC: A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations. Report STUK-A139. Helsinki: Finnish Centre for Radiation and Nuclear Safety, 1997
2 International Commission on Radiation Units and Measurements. Patient dosimetry for X-rays used in medical imaging. ICRU Report 74, J. ICRU, 5(2), 2005
3 D. Hart, M. C. Hillier, B. F. Wall: Doses to Patients from Medical X-ray Examinations in the UK–2000 Review, NRPB-W-14, National Radiologigal Protection Board, Chilton, 2002
4 Toivonen: M. Patient dosimetry protocols in digital and interventional radiology. Radiat. Prot. Dosim. 94(1-2), 105-108, 2001   DOI
5 E. Ariga, S. Ito, S. Deji, T. Saze and K. Nishizawa: Development of dosimetry using detectors of diagnostic digital radiography systems, Med. Phys. 34, 166-174, 2006   DOI
6 T. Chuan-Jong, and T. Hui-Yu: Evaluation of gonad dose and fetal doses for diagnostic radiology. Proc. Natl Sci. Council ROC B 23(3), 107-113, 1999
7 IAEA Safety Series No.115, International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, 1996a
8 R. A. Parry, A. G. Sharon, and R. A. Benjamin: Typical patient dose in diagnostic radiology: the AAPM/RSNA physics tutorials for residents. Radio-Graphics 19, 1289-1302, 1999
9 European Commission: European guidelines on quality criteria for diagnostic radiographic images, EUR 16260 EN (Brussels: EC), 1996
10 G. Compagnone, L. Pagan, L. and C. Bergamini: Local diagnostic reference levels in standard X-ray examinations, Radiat. Prot. Dosim. 113, 54-63, 2005   DOI
11 ICRP. Avoidance of radiation injuries from medical interventional procedures. ICRP Publication 85, Ann. ICRP 30(2), 2001b
12 P. R. Granfors and R. Aufrichtig: Performance of a 41${\times}$41-cm2 amorphous silicon flat panel X-ray detector for radiographic imaging applications, Med. Phys. 27, 1324-1331, 2000   DOI   ScienceOn
13 A. Herrmann., H. Bonel., A. Stablier., et al. Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients. Eur. Radiol. 12, 385-390, 2002   DOI   ScienceOn
14 E. Samei, J. G. Hill, G. D. Frey, W. M. Southgate, E. Mah, D. Delong: Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates, Med. Phys. 30, 601-607, 2003   DOI   ScienceOn
15 A. R. Cowen., A. Workman and J. S. Price: Physical aspects of photostimulable phosphor computed radiography, Br. J. Radiol. 66, 332-345, 1993   DOI   ScienceOn