• Title/Summary/Keyword: EMTDC model

Search Result 235, Processing Time 0.033 seconds

A Study on the Application Analysis of the Resistive type Superconducting Fault Current Limiters using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저항형 초전도한류기의 계통적용분석 연구)

  • Heo Tae Jeon;Bang Jong Hyun;Bae Hyeong Thaek;Park Min Won;Yu In Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2005
  • Since the discovery of the high temperature superconductors many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means In limit fault current in power systems. HTS resistive type SFCL is based on the ultra fast transition from the superconducting (non resistive) state to the normal (resistive) state by overstepping the critical current density, In this study, the simulation method of resistive type superconducting fault current limiter using EMTDC is proposed and the developed EMTDC model of SFCL is applied to the modeled power network using the Parameters of real system.

Development of the UPFC Switching Level Simulation Model using EMTDC (EMTDC를 이용한 UPFC의 스위칭 레벨 시뮬레이션 모형 개발)

  • Han, B.M.;Baek, S.T.;Moon, S.I.;Lee, H.S.;Yoo, I.D.;Chu, J.B.;Jang, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.15-19
    • /
    • 2001
  • 본 논문에서는 한전에서 강진변전소에 파이롯플랜트로 설치 중에 있는 80MVA 용량의 3-레벨 12-펄스형 UPFC의 EMTDC 모델링에 대해 기술하고 있다. UPFC의 EMTDC를 이용한 시뮬레이션 모형은 그 목적에 따라 상세 정도가 상이한 다양한 형태가 존재하나 본 연구에서는 향후 RTDS에 연계하여 전력계통과의 동적 성능 평가에 적용 가능하도록 인버터를 스위칭 레벨 다중펄스 전압원으로 모델링하였다. 개발된 시뮬레이션모형의 타당성은 정현파 이상진원을 사용한 시뮬레이션 분석결과와 비교검토 하여 검증하였다. 개발된 시뮬레이션모형은 UPFC의 성능분석과 전력계통과의 동적응동 해석에 유용하게 활용 가능하고 또한 UPFC 운전자에게 동작특성과 초보적인 운전특성을 교육하는데도 활용가능 할 것으로 보인다.

  • PDF

A Study on Analysis of Impulse Track Circuit using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 임펄스 궤도회로의 계통분석 연구)

  • Park, Ki-Bum;Lee, Tae-Hoon;Ryu, Young-Tae;Jeon, Yong-Joo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.433-441
    • /
    • 2009
  • We have studied a weird phenomenon on the High Voltage Impulse Track Circuit (HVITC). The biggest problem is that can not recognize the fault states, despite the fact the rail is broken. This study has shown that current HVITC systems can be operated even an ill-contact state of impedance bond lead wire. This study was carried out using various methods, such as measurements using an oscilloscope with voltage and current probes, simulations using PSCAD/EMTDC software tool, and analysis of measured data. Especially, we have simulated the fault state through bypass circuits using PSCAD/EMTDC software tool. We made a model of track circuit and simulated various types of fault states.

  • PDF

A Study of Channel Modeling and Simulation for Power Line Communication Systems using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전력선통신 채널모델링 및 시뮬레이션에 관한 연구)

  • Lee, Jong-Joo;Cha, Jae-Sang;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.6
    • /
    • pp.279-285
    • /
    • 2006
  • Power line communication channels are very complicated and models for communication channels vary with the types of electrical equipment, devices and load fluctuations. So, modeling and analysis of power line channels for implementation of power line communication systems is a very important process. Power line channel modeling and simulation are performed based on power system transient simulation models and power system CAD tools to create precise and accurate models. In this paper, a channel modeling and simulation method is proposed for power line communication systems using PSCAD/EMTDC, in which a PN 63 sequence code generator is applied for impulse response of the power line channel in the simulation model.

Development of User-defined Components for Dynamic Test of Distance Relay Models Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 거리계전기 동특성 시험에 관한 컴포넌트 모델 개발)

  • Lee, Hong-Hak;Lee, Tae-Young;Kim, Ho-Pyo;Nho, Jang-Hyun;Kang, Kun-Soo;Jang, Sung-Hoon;Lee, Jae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.242-244
    • /
    • 2003
  • The functional test of protection relays is divided into two kind of test types; the steady-state test and dynamic test. Because the steady-state test is comparatively easy, this test is used to test the characteristics of the relaying elements, operating values, resetting values and etc. using equipment such as Doble. But the dynamic test has to be performed on the test environment with RTDS(real time digital simulator) because of the dynamic characteristics of real protection relays. Therefore, it is not usually easy to perform dynamic test of relays using power system simulation tool based on PC(personal computer) such as PSCAD/EMTDC. This paper discusses how to develop and implement a test model and user-defined components that can be performed dynamic test using PSCAD/EMTDC.

  • PDF

Development of wind power generator system model using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전 시스템 모델 개발)

  • Kim, Young-Ju;Park, Dae-Jin;Ali, Mohd Hasan;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2000-2001
    • /
    • 2007
  • Wind power generation system based on the PSCAD/EMTD is proposed in this paper for the simulations under the real weather conditions. Real field data of weather condition is interfaced to PSCAD/EMTDC using Fortran program interfaced method. And a new turbine component is developed using characteristic equation of a wind turbine and pitch angle control algorism. The generator output and current supplied into utility can be obtained by the transient analysis using PSCAD/EMTDC.

  • PDF

EMTDC Modeling Method of Resistive type Superconducting Fault Current Limiter

  • Taejeon Huh;Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.60-65
    • /
    • 2003
  • An effective modeling and simulation scheme of a resistive type Superconducting fault Current Limiter (SFCL) using PSCAD/EMTDC is proposed in this paper. In case of High Temperature Superconducting (HTS) resistive type fault current limiter current limiting is implemented by the ultra-fast transition characteristics from the superconducting (non-resistive) state to the normal (resistive) state by overstepping the critical current density. The states can generally be divided into three sub-states: the superconducting state the quench state and the recovery state respectively. In order to provide alternative application schemes of a resistive type SFCL, an effective modeling and simulation method of the SFCL is necessary. For that purpose, in this study, an actual experiment based component model is developed and applied for the simulation of the real resistive type SFCL using PSCAD/EMTDC. The proposed simulation scheme can be implemented to the grid system readily under various system conditions including sort of faults and the system capacity as well. The simulation results demonstrate the effectiveness of the proposed model and simulation scheme.

Development of the Simulation Model of Micro-Grid using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 마이크로그리드의 시뮬레이션 모델 개발)

  • Son, Kwang-M.;Lee, Kye-B.;Hong, Jun-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.457-464
    • /
    • 2007
  • Micro-Grid comprising Micro-Sources supplying several $kW{\sim}MW$ power to local customers is environmentally friendly and reliable. This paper deals with the development of simulation models of Micro-Grid on the PSCAD/EMTDC platform for analyzing various aspects of the interaction of the Micro-Grid. The developed switching level model adopts the space vector PWM. Both switching level and power frequency Micro-Source models are developed, which shows that power frequency modeling is sufficient for analyzing the phenomena of interest. Control characteristics of the Micro-Sources with the parameter and load power variation are analyzed for power quality enhancement. The simulation results show that the developed models are effective for studying Micro-Grid.

Development of 1.5MVA wind power system model using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 고창 시험 설비 단지 1.5MVA 풍력 시스템 모델 개발)

  • Yun, Dong-Jin;Han, Byung-Moon;Choy, Young-Do;Jeon, Young-Soo;Jeong, Byoung-Chang;Chung, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.98-100
    • /
    • 2008
  • This study proposes a model of 1.5MVA wind power system in Go-chang field demonstration and performs simulation according to variable wind speed. 1.5MVA wind power system was verified by computer simulations with PSCAD/EMTDC software. Terminal voltage, grid voltage and active/reactive power can be observed through the simulation results.

  • PDF

Modeling of the HTS Fault Current Limiter Considering Quenching Characteristic (퀸칭 특성을 고려한 EMTDC 저항형 초전도 한류기 모텔링)

  • 윤재영;김종율;이승렬
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.73-79
    • /
    • 2004
  • Nowadays, one of the serious problems in KEPCO system is the larger fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). However, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC model for resistive type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching Phenomena occur.