• 제목/요약/키워드: Dust Loading

검색결과 64건 처리시간 0.021초

Case Studies of Mass Concentration Variation in the Central-Southern Korean Peninsula Caused by Synoptic Scale Transport of Dust Storms

  • Kim, Hak-Sung;Cho, Jae-Hee
    • 한국지구과학회지
    • /
    • 제40권4호
    • /
    • pp.414-427
    • /
    • 2019
  • In East Asia, the long-range transport of dust storms originating from Mongolia and northern China affects airborne dust loadings over downwind areas in the southern Korean Peninsula. Since 1997, dust loading cases caused by dust storms have been observed using the thresholds of total suspended particles (TSP, ${\geq}250{\mu}g\;m^{-3}\;hr^{-1}$) and particulate matter less than $10{\mu}g$ ($PM_{10}$, ${\geq}190{\mu}g\;m^{-3}\;hr^{-1}$) in the central-southern Korean Peninsula. There were two dust loading cases that exceeded these thresholds in 2016 and three in 2017, which reflects the downward trend of the last twenty-one years in the central-southern Korean Peninsula. Furthermore, five other dust loading cases with mass concentrations lower than the thresholds were observed from 2016 to 2017. In the moderate dust loading cases exceeding the thresholds, a descending motion of cut-off lows below $45^{\circ}N$ and a southward trough at 500 hPa gpm isopleths intensified at the western ridge, and largely extended the surface high-pressure system over southeast China. Airborne dust loadings following pronounced north-westerlies in the forward side of the high-pressure system were transported to the surface of the central-southern Korean Peninsula. However, in slight dust loading cases lower than the thresholds, the restricted descending motion of cut-off lows over $45^{\circ}N$ and the southwestward trough at 500 hPa gpm isopleths intensified the zonal flow over the Korean Peninsula. Surface high- and low-pressure systems moved eastward from the source compared to moderate dust loading cases. Due to the zonal movement of dust storms traversing eastern China, slight dust loading cases were observed with relatively higher ratios of $PM_{2.5}/TSP$ and carbon monoxide (CO) in the central-southern Korean Peninsula.

접선유입 방식 여과집진기의 내통형상 변화에 따른 집진특성 연구 (A Study on the Filtration Characteristics of Baghouse with Tangential Inlet Depending on the Shape of Inner Tube)

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.158-161
    • /
    • 2001
  • A new type baghouse with tangential inlet and inner tube was developed and it's performances were evaluated. Experiments with variable shapes of inner tube were performed to suggest an optimum shape of inner tube which might decrease the dust loading onto bag filter surface and the amount of reentrained particles by internal gas flow. The dust loading was lower when inner tubes parallel to outer casing exist. When an inner tube covering around the lower portion of bag filters was used, the dust particles detached from the filter surface by cleaning process were reentraind by internal recirculating gas flow.

  • PDF

포장도로 재비산먼지 배출계수 산정을 위한 silt loading의 실시간 측정시스템 개발과 적용 (Development and Application of Real-time Measurement System of Silt Loading for Estimating the Emission Factor of Resuspended Dust from Paved Road)

  • 한세현;원경호;장기원;손영민;김정숙;홍지형;정용원
    • 한국대기환경학회지
    • /
    • 제23권5호
    • /
    • pp.596-611
    • /
    • 2007
  • Resuspended dust from paved roads in Seoul and Incheon metropolitan areas is regarded as one of the major $PM_{10}$ sources in these areas, according to the recent emission estimates using the emission factors compiled in AP-42. It is well known that the AP-42 model for estimating $PM_{10}$ emissions from paved roads requires information on silt loadings of particular paved roads. The conventional AP-42 method (vacuum swept method) for road silt sampling, however, is expensive, time consuming, and dangerous. These drawbacks led us to develop a Mobile Dust Monitoring System (MDMS) capable of doing real time measurements of silt loading of paved roads, thereby we could get higher resolution silt loading data both in terms of time and space without too much human efforts and danger. In this study, for the real-time measurement of silt loading of paved roads, the principle used in the TRAKER method of U.S. Desert Research Institute was employed and the entire sampling systems including data acquisition system were designed for theses purpose and mounted on a SUV. The correlation between the silt loading measured by vacuum swept method and the speed corrected ${\Delta}Dust$ was derived for the vehicle-based silt loading measurements, and then the variations of silt loading on paved roads were surveyed using the MDMS in test routes of Seoul and Incheon. From the results of real-time measurements, temporal and spatial variations of silt loading data together with the existence of hot spots were observed for paved roads in Seoul and Incheon. The result of this study will be employed to estimate fugitive dust emissions from paved roads.

황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거 (A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate)

  • 서정민
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

화물차 적재 방식에 따른 축 하중을 고려한 타이어 먼지 중 PM10 발생량 평가기법 연구 (Study on the assessment methodology for the PM10 generated from tire-dust considering the axle load of the truck according to the loading method)

  • 이은정;이희관
    • 도시과학
    • /
    • 제11권2호
    • /
    • pp.45-54
    • /
    • 2022
  • Recently, regulations on automobile exhaust gas emission are being strengthened. Accordingly, automobile exhaust gas emissions are expected to decrease and continue to decrease. On the other hand, many countries do not yet consider the emission of non-exhaust air pollutants from automobiles as important. Automobile non-exhaust substances are classified into three categories: tire dust emissions, brake wear emissions, and road scattering dust. In particular, in the case of tire dust, research results exist that pollutant emissions increase as the weight of a vehicle increases. Since the weight of trucks varies according to the load and the load along the axles is also different, it can be expected that the emission of PM10 from the tire dust will be different depending on the loading method. Therefore, this study was conducted on the amount of PM10 generated in tire dust considering the axle load of the truck according to the loading method. However, it was confirmed that the total amount of PM10 was less than that all loads are loaded in the front or rear when the load was evenly distributed in the front and rear of the cargo compartment. In particular, if the load is distributed evenly in the front and back of the cargo compartment and the load in the front part is divided into 2 to 6 and loaded, as the number of divided loading increases the amount of PM10 generated decreases. And when the load is divided into 6 pieces, the total amount of PM10 generated is 0.3952g, the minimum value. If the load is divided into 6 or more and loaded evenly, the total PM10 generated continuously increases and converges to about 0.3964g.

China Dust-storm Monitoring Using Meteorological Satellite

  • Xiuqing, Hu;Naimeng, Lu;Peng, Zhang;Qian, Huang
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1224-1226
    • /
    • 2003
  • Dust-storm is one of the heaviest hazardous weather which frequently affects most part of northern China in spring. Satellite multi-spectral observations can provide significant information for detecting and quantitative determining the property of dust-storm . An algorithm to monitor dust-storm automatically was developed based on satellite observation. The algorithm utilizes split widows technique and spectral classification technique and also developed a new dust remote sensing product Infra -red Difference Dust Index (IDDI) proxy dust-loading dataset using GMS-5.

  • PDF

작업환경개선을 위한 목재포장공정에 있어서의 양끝절단포장적재장치 개발 (The package loading equipment development cutting both ends in the process of packaging lumber for improving the working environments)

  • 강지호;홍동표
    • 산업경영시스템학회지
    • /
    • 제29권1호
    • /
    • pp.135-142
    • /
    • 2006
  • The package loading process of tile lumbering industry is an operation that after a pair of workers binds three or six lumber into a unit and cut the both ends of the lumber, carry and pack and load the weight cargo of 30-50kg. The package loading process causes lots of noise and wood dust when the lumber are cut and brings about the main cause of the musculoskeletal disorder when workers carry the heavy goods. Therefore, we developed the monolithic package loading equipment cutting both ends that is enable to improve the working method and environments of the existing package loading process. The noise and wood dust were reduced by developing the device and the main cause of shirking duties on working place was solved by preventing the musculoskeletal disorder and improving the working environments as excluding the work of carrying heavy goods.

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

활성탄전극을 이용한 분진제거에서 전극의 적정 간격에 관한 연구 (Optimal Distance between Positive and Negative Electrode-Plates Coated with Activated Carbon in Dust Removal Chamber)

  • 김광수;박현철;전태환;이주행;남상철
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.821-826
    • /
    • 2013
  • 본 연구의 목적은 분진제거 장치에서 전극간의 적정간격을 알아보기 위한 것이다. 실험은 전극간격을 3 cm, 2 cm, 1 cm로 직렬로 놓고 유입유량을 변화시켜 수행하였다. 실험결과로부터 분진제거를 위한 적정 선속도는 6 cm/sec였고 전극표면에 부착되는 분진 총량은 전극의 간격이 가까울수록 증가하였다. 그러나 1 cm 정도로 매우 가까울 경우는 전극판에 부착된 분진은 탈착되었으며 이는 분착된 분진의 역이온화 즉 전하의 변화 때문인 것으로 사료되었다. 결과적으로 전극판에서 양전극과 음전극 간의 간격은 2 cm가 적당하고 이때의 분진부하율은 $24mg/min{\cdot}m^2$였다.

제전사여과포의 개발 및 기초성능 규명 (Development and Basic Performance Characterization of Neutralized Fabric Filter)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.57-64
    • /
    • 1998
  • 폴리에스터와 스테인레스스틸섬유를 재료로 제조된 제전사여과포에 대한 물리화학적 특성시험 및 여과포성능 기초시험을 수행하였다. 실험용먼지로 제철.제강, 시멘트제조, 열공급시설 및 폐기물공정에서 채취된 먼지를 처리하여 사용하였다. 제전사여과포의 물리화학적 특성 실험에서는 산성분위기하에서 인장강도 및 초기탄성계수변화를 조사하였고, Automated Permporometer를 이용하여 평균흐름세공압력, 기포점 세공지름, 평균흐름세공지름 및 세공크기분포를 구하였다. 또한 벤처규모의 여과포 기초성능 시험장치를 이용하여 먼지부하에 따른 압력손실, 먼지통과율 및 여과포성능 평가지표를 산출하였다. 산성가스 및 분위기하에서 제전사여과포의 인장강도는 온도 및 노출시간과 깊은 관련이 있었다. 압력손실은 여과속도와 먼지부하가 증가함에 따라 증가하였으며 증가형태는 먼지의 종류에 따라 달랐다. 먼지 통과율은 먼지종류에 관계없이 먼지부하의 증가에 따라 급격히 감소하는 경향을 나타내었다. 여과포성능지표는 먼지 포집 초기에는 증가했다가 급격히 감소하여 일정하게 유지되었다.

  • PDF