Browse > Article

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System  

Kim Sang-Do (한국에너지기술연구원 청정에너지연구부)
Park Young-Ok (한국에너지기술연구원 청정에너지연구부)
Kang Yong (충남대학교 화학공학과)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.20, no.6, 2004 , pp. 739-748 More about this Journal
Abstract
A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.
Keywords
Hybrid fabric filter; Fabric filter; Centrifugal force; Pressure drop; Collection efficiency; Fractional collection efficiency;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김상도,손재익,박영옥,정동규,강용 (2004) 원심력이 적용된 여과포집진장치에서 유동장 및 업자거동 특성, 화학공학, 42(3), 318-325
2 김종석, 조명식 (1991) 대기오염방지기술, 2판, 동화기술, 520 pp
3 Choi, H.K., S.J. Park, J.H. Lim, S.D. Kim, H.S. Park, and Y.O. Park (2002) A Study on the Characteristics of Improvement in Filtration Performance by Dust Precharging, Korean J. Chem. Eng., 19(2), 342-346.   DOI   ScienceOn
4 Ogawa, A. (1984) Separation of Particlesfrom Air and Gases, CRC Press Inc., Boca Raton, Florida
5 박석주, 최호경, 김상도, 박영옥 (2001) 접선유입방식 여과포집진장치에서 내통이 유풍장 및 입자거동에 미치는 영향, 화학공학, 39(4), 438-445
6 Leith, D. and M. First (1978) Air Pollution Control Technology, Van Nostrand Reinhold Company Inc.
7 Gregg, W. and G.J. Daies (1992) Impoving Pulse-Jet Dust Collector Operation; The Effect of Gas Stream Inlet Design, The User and Fabric Filtration Equipment VI, Proceedings of an International Specialty Conference, Toronto, Ontario, 37
8 Fayed, M.E. and L. Ottoen (1984) Handbook of Powder Science and Technology, Van Nostrand Reinhold Company Inc.
9 여석준 (2000) 하부유입식 원심여과집진장치의 특성, 대한환경공학회지, 22(4), 639
10 Billings, C.E. and J.E. Wilder (1970) Handbook of Fabric Filter Technology, Vol. 1, GCA Technology Division, Bedford
11 손재익, 박영옥, 구철오, 김상도, 임정환, 김홍룡(1998) 산업용 직불여과포집진장치 국산화 개발, 제 2단계 단계보고서, 환경부, 83-188
12 Park, S.J., H.K. Choi, Y.O. Park, and J.E. Son (2003) Effects of a Shroud Tube on Flow Field and Particle Be havior Inside a Bagilter Vessel, Aerosol Science and Technology, 37, 685-693
13 Shepherd, C.B. and C.E. Lapple (1939) Flow pattern and pressure drop in cyclone collectors, Ind. Eng. Chem., 31 ,972