• Title/Summary/Keyword: Drum level

Search Result 77, Processing Time 0.04 seconds

Fuzzy control of drum level of boiler in thermal power plant (화력발전소 보일러 드럼 수위 퍼지 제어)

  • 변승현;박두용;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.195-198
    • /
    • 1996
  • The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant setpoint regardless of disturbance such as main steam flow. The initial response of the drum level loop process is in a direction opposite to the final response. The drum level loop shows inverse response when the power is changed abruptly. We adopt fuzzy controller using knowledge base considering system dynamics for controlling drum level. Finally, the simulation result using the digital simulator for boiler system in Seoul Power Plant Unit 4 shows the validity of fuzzy controller.

  • PDF

A study on the design of level control system for boiler drum (보일러 증기발생기 수위 제어 시스템 설계에 관한 연구)

  • 허성광;박익수;황재호;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.85-89
    • /
    • 1990
  • In this paper, the design of boiler drum level control system is important in power plant is studied. First of all, pressure compansation of level for boiler drum which is close tank with high temperature and pressure is designed. Physical penomena of drum level are analysed, controllers are designed, and simulation results are shown. Designed controller have a good performance compare with PI controller. Predictive controller of boiler drum level control system is proposed. It will be good system for boiler drum level control to reject the disturbance according to lead increase or decrease.

  • PDF

Auto-tuning of boiler drum level controller in Thermal Power Plant (화력 발전소 보일러 드럼수위 제어기의 자동 동조)

  • Lee, J.H.;Joo, H.Y.;Byun, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2584-2586
    • /
    • 2000
  • A drum level control is one of the most important control systems in thermal power plant. The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant set-point regardless of disturbance such as main steam flow. The implemented drum level controller is the cascade PI controller. The important factor in drum level controller is the parameters of two PI controllers. The tuning of PI controller parameter is tedious and time-consuming job. In this paper, the relay feedback Ziegler - Nichols tuning method extended to auto-tune cascade PI drum level controller. Finally, the simulation result using boiler model in Power Plant shows the validity of auto-tuned cascade PI controller.

  • PDF

Improvement in power plant feed water system (발전소의 급수 제어시스템의 개선)

  • 배영환;황재호;서진헌
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.553-556
    • /
    • 1989
  • Nowadays in power plant feed water control, it is very important to retain the stable drum level though power changes very fast. For the stable drum level in power plant, we have to model our plants and get the system functions. We make the L.Q. controller by using these functions and apply it to these systems. And we get the more stable drum level which is controlled by feed water qualities.

  • PDF

Fuzzy-PI Cascade Control of Drum Level of Boiler in Thermal Power Plan (화력 발전소 드럼수위의 퍼지-PI 캐스케이드 제어)

  • Byun, S.H.;Cho, J.Y.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.458-460
    • /
    • 1998
  • The drum level control is initiated by 1-element manual control, and then the control mode is changed to 1-element automatic control mode. Finally, the drum level control is changed to 3-element automatic control mode by the logic based on pre-defined threshold of main steam flow. In terms of plant automation, the automatic 1-element control mode is required from the start-up of boiler. In this paper, the fuzzy controller is adopted for automatic 1-element control of drum level from start-up. It is suggested that the fuzzy controller is used in 1-element control, and the fuzzy-PI cascade controller is used in 3-element control. Finally, the validity of suggested control scheme is shown via simulation.

  • PDF

Design of Connectivity Test Circuit for a Direct Printing Image Drum

  • Jung, Seung-Min
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.43-46
    • /
    • 2008
  • This paper proposes an advanced test circuit for detecting the connectivity between a drum ring of laser printer and PCB. The detection circuit of charge sharing is proposed, which minimizes the influences of internal parasitic capacitances. The test circuit is composed of precharge circuit, analog comparator, level shifter. Its functional operation is verified using $0.6{\mu}m$ 3.3V/40V CMOS process parameter by HSPICE. Access time is100ns. Layout of the drum contact test circuit is $465{\mu}m\;{\times}\;117{\mu}m$.

A Study on Accuracy Improvement in Measuring Liquid Level inside Pressurized Vessels (압력 용기 수위 측정 오차 개선에 관한 연구)

  • Kim, Ho-Yol;Byun, Seung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1889-1893
    • /
    • 2010
  • Differential pressure type level measuring systems have been using widely for industrial applications like drum level measurements in power plants. Because of difficulties in specific gravity compensation for vapor and liquid inside the vessel and the sensing lines, this type of measuring systems reveal significant measuring error. In this paper, the major reason causing errors on the differential pressure type level measurement is analyzed and a method of more accurate calculation for specific gravity compensation is introduced.

The Effect of Group Music Therapy Using the Traditional Drum on the Social-Adjustment, Self-Conception and Emotional-Adjustment of Children with Hearing Impairment (전통 북을 활용한 집단 음악 치료가 청각 장애 아동의 사회적응과 자아상 및 정서적응에 미치는 영향)

  • Sung, Mi-Kyeong;Cheong, Kwang-Jo;Choi, Ae-Na
    • Journal of Families and Better Life
    • /
    • v.30 no.6
    • /
    • pp.85-101
    • /
    • 2012
  • This study was conducted to investigate the effect of group music therapy using the traditional drum on the; social adjustment, self-image, and emotional adjustment, of children with hearing impairment. I participated in this group music therapy using the traditional drum with 7 children with hearing impairment for 3 days a week for 6 weeks(including holidays), and each session was 50 minutes long. The evaluation form of this study is a social-emotional development measurement sheet of Meadow-Kendall, which the children's teacher distributed to the children both pre- and post-examination. With these results, the researcher carried out Window SPSS 19 Version and searched for the experiment's effect of measurement cause (I am not sure what this means.) through paired t-test to identify the experiment's effects (social adjustment, self-image, emotional adjustment) as a result of group music therapy using the traditional drum for children with hearing impairment. This study arrived at the following conclusions. First, after I participated in the group music therapy using the traditional drum, the result of the comparisons of the pre-to-post average for social adjustment showed the statistical significance level of the 0.01 standard. Therefore, it was found that the group music therapy using the traditional drum had a positive effect on the social adjustment of children with hearing Impairment. Second, after I participated in the group music therapy using the traditional drum, the result of the comparisons of the pre-to-post average for self-image development showed the statistical significance level of the 0.01 standard. Therefore, the group music therapy using the traditional drum had a positive effect on the self-image of children with hearing impairment. Third, after I participated in the group music therapy using the traditional drum, the result of the comparisons of the pre-to-post average for emotional adjustment showed the statistical significance level of the 0.01 standard. Therefore, the group music therapy using the traditional drum had a positive effect on the emotional adjustment of children with hearing impairment.

Investigation of Automatic Drying Algorithm to Combi-Drum Washer of the Condensing Type (응축 방식의 건조 일체형 드럼세탁기에서의 자동 건조 알고리즘에 관한 연구)

  • Chung, Young-Suk
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.205-209
    • /
    • 2003
  • The condensation water temperature $(T_{CW})$ distributions on the combi-drum washer of condensation type which the cloth washes, rinses, spins and dry cloth over a heater were measured using the thermocouples. During the drying process, in order to find out the relationship between the $T_{CW}$ distribution and the cloth dryness level $(C_{D1})$, the experiment was made for the dehydration rate of the cloth $(C_{D0})$ is 63%, the weight of cloth $(W_{C0})$ from 1 to 6kg. In result, according to $W_{C0}$ and $C_{D0}$, the distributions of $T_{CW}$ are very different. Using this tendency, it was appropriate and it developed the automatic drying algorithm and it was gotten dryness level regardless of $W_{C0}$, $C_{D0}$ and the other factor.

  • PDF

Fuzzy Controller Design for Water level Control of Power Plant Drum (화력발전소 드럼의 수위제어를 위한 퍼지 제어기의 설계)

  • 이상혁
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2003
  • In this paper, we propose a fuzzy controller design method for the water level control of the power plant drum in the form of nominimum phase system The proposed method is based on T. Takagi and H. Sugeno's fuzzy model. And we illustrate the improved characteristics as the simulation results, comparing with the conventional the PID and LQ controller design methods.