• Title/Summary/Keyword: Drug-eluting stents (DES)

Search Result 17, Processing Time 0.022 seconds

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

Use of Drug-eluting Stents Versus Bare-metal Stents in Korea: A Cost-minimization Analysis Using Population Data

  • Suh, Hae Sun;Song, Hyun Jin;Jang, Eun Jin;Kim, Jung-Sun;Choi, Donghoon;Lee, Sang Moo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.4
    • /
    • pp.201-209
    • /
    • 2013
  • Objectives: The goal of this study was to perform an economic analysis of a primary stenting with drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with acute myocardial infarction (AMI) admitted through an emergency room (ER) visit in Korea using population-based data. Methods: We employed a cost-minimization method using a decision analytic model with a two-year time period. Model probabilities and costs were obtained from a published systematic review and population-based data from which a retrospective database analysis of the national reimbursement database of Health Insurance Review and Assessment covering 2006 through 2010 was performed. Uncertainty was evaluated using one-way sensitivity analyses and probabilistic sensitivity analyses. Results: Among 513 979 cases with AMI during 2007 and 2008, 24 742 cases underwent stenting procedures and 20 320 patients admitted through an ER visit with primary stenting were identified in the base model. The transition probabilities of DES-to-DES, DES-to-BMS, DES-to-coronary artery bypass graft, and DES-to-balloon were 59.7%, 0.6%, 4.3%, and 35.3%, respectively, among these patients. The average two-year costs of DES and BMS in 2011 Korean won were 11 065 528 won/person and 9 647 647 won/person, respectively. DES resulted in higher costs than BMS by 1 417 882 won/person. The model was highly sensitive to the probability and costs of having no revascularization. Conclusions: Primary stenting with BMS for AMI with an ER visit was shown to be a cost-saving procedure compared with DES in Korea. Caution is needed when applying this finding to patients with a higher level of severity in health status.

Development of Evaluation Method for Drug Release Propreties in Drug Eluting Stent (약물방출스텐트의 약물 방출 특성 평가 방법 개발)

  • Song, J.M.;Baek, H.;Lee, S.Y.;Jang, D.H.;Seo, M.Y.;Park, G.J.;Maeng, Eun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.69-72
    • /
    • 2013
  • The goal of this study is to develop test method for evaluating the drug eluting properties of drug eluting stents (DES). PBS and the detergent solutions, presented by each DES manufacturer, were used for drug release of DES coated with paclitaxel, zotarolimus and everolimus. The drugs which are coating DES were not released by PBS but released by the detergent solutions, finally paclitaxel 83.38%, zotarolimus 103.85% and everolimus 115.78%. It seems that the use of the detergents is necessary in order to release the drugs because those drugs are extremely hydrophobic. In conclusion, using of detergent solutions presented by each manufacturer were suitable for evaluating the drug eluting property of drug eluting stent.

Occurrence and Prognosis for the Thrombosis in the Drug-Eluting Stents and Bare-Metal Stents (약물 용출 스텐트와 일반 금속 스텐트에서 혈전증에 대한 발생과 예후)

  • Kim, In-Soo;Choi, Nam-Gil;Jang, Seong-Joo;Han, Jae-Bok;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.273-283
    • /
    • 2012
  • Drug-eluting stents (DES) have significantly reduced in-stent restenosis, compared to bare-metal stents (BMS). However, there remains concern for the increased risk of stent thrombosis (ST) associated with DES. The present study sought to evaluate the incidence, clinical characteristics and outcome of ST in patients with acute myocardial infarction (MI) during a 1-year follow-up. 80 patients who developed ST were divided into 2 groups according to stent type: group I (DES-ST, n = 57 ) and group II (BMS-ST, n = 23 ). There were no differences between group I and II in the overall incidence of ST (2.7% vs. 4.3%, p=0.064) and in the incidence of each type of ST: acute ST (8.8% vs. 2.3%), subacute ST (50.9% vs. 60.9%), late ST (19.3% vs. 8.7%), and very late ST (21.1% vs. 17.4%) (p=0.605). Predictors of 1-year mortality were the occurrence of ST (OR 8.12, 95% CI 2.83-23.61, p<0.001), left ventricular ejection fraction<40% (OR 6.41, 95% CI 2.42-16.96, p<0.001), and age${\geq}$75 years (OR 4.98, 95% CI 1.95-12.74, p=0.001).

Controlled Release of Paclitaxel from Biodegradable Polymer Films for Drug-Eluting Stents (약물방출 스텐트용 생분해성 고분자 필름으로부터 파크리탁셀의 조절 방출)

  • Kim, Si-Eun;Lee, Bong-Soo;Kim, Jin-Hyang;Park, Kwi-Deok;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • Although many researchers have studied the efficacy of paclitaxel (PTX) on many cells during the last two decades, little work has been reported on the importance of release kinetics inhibiting cell proliferation. The aim of this study is to examine the release behavior of the PTX on various biodegradable polymers such as poly(lactic-co-glycolic acid)(PLGA), poly-L-lactide (PLLA), and polycaprolactone (PCL) for drug-eluting stents (DES). The PTX from the fabricated films was released for 8 weeks and the degree of degradation of the films was observed by FE-SEM. Although the degradation time of PCL was the slowest, the PTX release rate was the fastest among them and followed by PLGA and PLLA with the equivalent PTX concentration. It suggests that hydrophobic drug such as PTX from polymer with low $T_g$ like PCL could be moved easily and released rapidly in body temperature.

Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents (생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동)

  • Kim, Dong-Min;Lee, Bong-Soo;Park, Cheol-Ho;Park, Kwi-Deok;Son, Tae-Il;Jeong, Myeong-Ho;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.178-183
    • /
    • 2010
  • Medical metal stents inserted to patients with a cardiovascular disease associated with coronary artery system have relatively increased the survival rate. The development of new stents is, however, urgently required due to restenosis and late thrombosis generated in metal stents. To solve these problems, the biodegradable polymers such as poly(lactide-co-glycolide) (PLGA), poly(L-lactide)(PLLA), and poly ($\varepsilon$-caprolactone)(PCL) were mixed with alpha lipoic acid (ALA), which is well known to inhibit the proliferation of neointimal hyperplasia. Subsequently, the ALA-loaded polymers were coated on stainless steel by electrospray. The drug-eluting behaviors from the coated polymers were investigated according to kinds and concentrations of polymers, spray rates, and kinds of solvents. The drug-eluting rate from PCL with the lowest glass transition temperature was the fastest among three polymers and followed by PLGA and PLLA. The surface roughness increased as the spray rate was increased and also the drug-eluting rate was affected by kinds of solvents with different boiling point. It is expected that drug-eluting stent (DES) coated with ALA-loaded polymers can be applied practically for clinical applications by controlling the behavior of drug release.

A Novel Deposition Method of PLGA Nanoparticles on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Pakr, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1085-1087
    • /
    • 2009
  • Bare metal stents which were used to treat coronary artery disease have several biochemical problems. Polymerbased drug-eluting stents (DES) have opened up a new paradigm in the treatment of in-stent restenosis. Many studies and research programmes have proved that DES can prevent restenosis. In our study, paclitaxel-loaded poly (lactic-co-glycolic acid) (PLGA) nanoparticles have been deposited along the three dimensional scaffold of coronary stents by a method using self-assembling properties of colloidal particles. We found that the nanoparticles were deposited uniformly and closely packed. The amount of paclitaxel was easily controlled by the drug content of the nanoparticles and the deposition count.

Numerical Study of Flow Pattern and Drug Deposition in Drug-Eluting Stent (약물분출 스텐트 주위 유동형태와 약물침전에 대한 수치해석)

  • Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1053-1060
    • /
    • 2011
  • This study is performed to determine the drug concentration profiles of drug-eluting stents (DES) for an ideal circular ring stent and intertwined stent models for various Reynolds numbers (Re = 200, 400, and 800). The Navier.Stokes equations coupled with the advection-diffusion equation are solved numerically in order to determine how the flow patterns and drug deposition are affected in the in-stent and post-stent regions where flow separation and recirculation occur. The presence of DES within the arterial segment affects the local drug distribution in the flow field. As a result, the drug concentration for the intertwined stent is higher over the in-stent region in comparison with the ideal stents. For a given stent geometry, the local drug concentration in the in-stent region decreases with Reynolds number, while for a given Reynolds number, the local drug concentration is relatively insensitive to the stent geometry. The results show that drug concentration along the arterial wall is significantly higher within the in-stent and post-stent regions for the intertwined stent geometry than for the ideal stent geometries.

Clinical Outcomes of Stent Thrombosis after Drug-Eluting Coronary Stent Implantation (약물방출 관상동맥 스텐트 시술 후 스텐트 혈전증 발생 환자의 임상경과)

  • Kim, In-Soo;Jeong, Myoung-Ho;Han, Jae-Bok;Jang, Young Ill;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.880-892
    • /
    • 2013
  • Stent thrombosis after successful drug-eluting stent(DES) implantation has been reported in around 1% of patients in clinical trials. However, the increased risk of ST associated with DES remains a matter of concern. From 1 June 2003 to 30 June 2013, we investigated clinical characteristics, in-hospital outcomes in 10,273 patients who underwent percutaneous coronary intervention in the Heart Center of CNUH. Overall incidence of ST was 1.30% (134 patients). The incidence of ST according to the stent generations and the timing of ST (n=total, early vs. late vs. very late) were 0.79% (n=81, 26 vs. 12 vs. 43) in first-generation, 0.38% (n=39, 21 vs. 9 vs. 9) in second-generation and 0.14% (n=14, 8 vs 3 vs. 3) in third-generation, (p=0.70). The mortality from ST was significantly higher in early ST group compared to the late and very late ST groups (18.2% vs. 8.3% vs. 3.6%, p=0.042). Overall incidence of ST after DES implantation was 1.30% (134 patients). The in-hospital mortality was significantly higher in early ST group compared to the late and very late ST groups.

Performance of Various Drug-Eluting Stent Geometries Measured Using Computational Analysis (여러 형상을 고려한 약물분출 스텐트의 성능에 대한 수치해석적 연구)

  • Seo, Tae-Won;Barakat, Abdul I.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.601-607
    • /
    • 2012
  • In this study, we performed computational fluid dynamic simulations to explore how the detailed design of drug-eluting stents affects both the flow field in the vicinity of the stent as well as the concentration of the eluted drug at the endothelial cell surface. Simulations were performed on three idealized stent geometries we developed and on geometries approximating three commercial stents,: Medtronic's Aurora stent, Cordis's BX Velocity stent, and Boston Scientific's Wallstent. An important contribution of the present study is the introduction of the stent effectiveness index (EI), which provides a quantitative assessment of stent performance and an objective basis for comparing the performance of different stents. Among the three commercial stents studied, our simulations have revealed that the BX Velocity stent is associated with the lowest in-stent EI values for the range of flow Reynolds numbers studied ($200{\leq}Re{\leq}800$). In addition to commercial stent designs, we investigated the EI in three idealized stents and determined that a spiral stent provides excellent performance (low EI) under all flow conditions investigated.