Performance of Various Drug-Eluting Stent Geometries Measured Using Computational Analysis  

Seo, Tae-Won (Dept. of Mechanical & Automotive Engineering, Andong Nat'l Univ.)
Barakat, Abdul I. (Dept. of Mechanics, Ecole Polytechnique)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.36, no.6, 2012 , pp. 601-607 More about this Journal
Abstract
In this study, we performed computational fluid dynamic simulations to explore how the detailed design of drug-eluting stents affects both the flow field in the vicinity of the stent as well as the concentration of the eluted drug at the endothelial cell surface. Simulations were performed on three idealized stent geometries we developed and on geometries approximating three commercial stents,: Medtronic's Aurora stent, Cordis's BX Velocity stent, and Boston Scientific's Wallstent. An important contribution of the present study is the introduction of the stent effectiveness index (EI), which provides a quantitative assessment of stent performance and an objective basis for comparing the performance of different stents. Among the three commercial stents studied, our simulations have revealed that the BX Velocity stent is associated with the lowest in-stent EI values for the range of flow Reynolds numbers studied ($200{\leq}Re{\leq}800$). In addition to commercial stent designs, we investigated the EI in three idealized stents and determined that a spiral stent provides excellent performance (low EI) under all flow conditions investigated.
Keywords
DES; SEI; CFD; Drug Concentration; Endothelial Cell;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Kastrati, A.J., Mehilli, J., Dirschinger, J., et al. , 2001, "Restenosis After Coronary Placement of Various Stent Types," Am. J. Cardiol., 87, pp.34-39.
2 Dangas, G.D., Claessen, B.E., Caixeta, A., Sanidas, E.A., Mintz, G.S. and Mehran, R., 2010, "In-Stent Restenosis in the Drug-Eluting Stent Era," J. Am. Coll. Cardiol., 56, pp.1897-1907.   DOI   ScienceOn
3 Duraiswamy, N., Cesar, J.M., Schoephoerster, R.T. and Moore, J.E., Jr., 2008, "Effects of Stents Geometry on Local Flow Dynamics and Resulting Platelet Deposition in an in Vitro Model," Biorheology, 45(5), pp.547-561.
4 Vrints, C.J., Claeys, M.J., Bosmans, J., Conraads, V. and Snoeck, J.P., 1999, "Effect of Stenting on Coronary Flow Velocity Reserve: Computation of Coil and Tubular Stents," Heart , 82, pp.465-470.   DOI
5 Seo,T.W., Schachter, L.G. and Barakat, A.I., 2005, "Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents," Annals of Biomedical Eng., 33(4), pp.444-456.   DOI
6 Seo, T.W., Kim, T.D. and Barakat, A.I., 2005, "Stent Design Using CFD," Trans. of the KSME (B) Vol. 29, No. 9, pp. 1042-1048.
7 Seo, T.W. and, Barakat, I.A, 2007, "Numerical Analysis on the Effect of Wall Shear Stress Around the Ring Drug-Eluting Stent," Trans. of the KSME (B), Vol. 31, pp.21-28.   과학기술학회마을   DOI   ScienceOn
8 Hwang, C.W. Levin, A.D. Jonas, M., Li, O.H. and Edelman, E.R., 2005, "Thrombosis Modulates Arterial Drug Distribution for Drug-Eluting Stents," Circulation 111, pp.1619-1626.   DOI   ScienceOn
9 Gruchalla, K.J.A. and Nawarskas, J.J., 2006, "The Paclitaxel-Eluting Stent in Percutaneous Coronary Intervention. Part I: Background and Clinical Comparison to Bare Metal Stents," Cardiology in Review 14, pp. 88-98.   DOI   ScienceOn
10 Yang, C. and Burt, H.M., 2006, "Drug-Eluting Stents: Factors Governing Local Pharmacokinetics," Adv. Drug Delivery Review 58, pp. 402-411.   DOI   ScienceOn
11 Kastrati, A.J., Mehilli, J., Dirschinger, J., et al., 2001, "Restenosis After Coronary Placement of Various Stent Types," Am. J. Cardiol., 87, pp.34-39.
12 Morton, A.C., Crossman, D. and Gunn, J., 2004, "The Influence of Physical Stent Parameters upon Restenosis," Pathol. Biol., 52(4), pp. 196-205.   DOI   ScienceOn
13 Berry, J.L., Santamarina, A., Moore, J.E. Jr., Roychowdhury, S. and Routh, W.D., 2000, "Experimental and Computational Evaluation of Coronary Stent," Ann. Biomed. Eng., 28, pp.386-398.   DOI   ScienceOn