• Title/Summary/Keyword: Double Coil

Search Result 146, Processing Time 0.026 seconds

A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum (진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작)

  • Yu, K.K.;Kim, K.;Lee, Y.H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

Ultrasonic Absorption Measurements of Bovine Serum Albumin Solutions in the Frequency Range 200 kHz to 3 MHz (주파수 200 kHz-3 MHz영역에 대한 알부민용액의 초음파 흡수측정)

  • Bae, Jong-Rim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1E
    • /
    • pp.14-19
    • /
    • 2006
  • Ultrasonic absorption and velocity spectra in bovine serum albumin (BSA) aqueous solutions have been measured at $20^{\circ}C$ over the frequency range 0.2-3 MHz in the pH range 1.5-13.2. The high-Q ultrasonic resonator and pulse-echo overlap methods were used. At acid pH's, excess absorption over that of pH 7 was explained by double relaxation. The pH dependences of the relaxation frequency and maximum absorption per wavelength, showed that the relaxation at about 200 kHz was related to the expansion of molecules and that about 3 MHz resulted from the proton transfer reaction of carboxyl group. At alkaline pH's, the excess absorption was explained by double relaxation. The relaxation at about 300 kHz was associated with a helix-coil transition, and that about 3 MHz was attributed to the proton transfer reaction of phenolic group. The rate constants and volume changes associated with these processes were estimated.

A study with multi-winding of double excited type LDM (양측 여자형 LDM의 다권선화에 관한 연구)

  • Lee, S.M.;Baek, S.H.;Kim, Y.;Yoon, S.Y.;Maeng, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.290-293
    • /
    • 2000
  • In this paper, by designing the width of the stator coil, double sided excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Permeance method, equvalent magnetic circuit method, Maxwell 2D, which is the magnetic field analysis package, we were analyzed and proved the validity of design process, also the characteristics of LDM according to magnet vs. coil width ratio of LDM was almost in accord with the experiment results.

  • PDF

A Four Pole, Double Plane, Permanent Magnet Biased Homopolar Magnetic Bearing with Fault-Tolerant Capability

  • Na, Uhn-Joo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_1
    • /
    • pp.659-667
    • /
    • 2021
  • This paper develops the theory for a novel fault-tolerant, permanent magnet biased, 4-active-pole, double plane, homopolar magnetic bearing. The Lagrange Multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrices for the failed bearing. If any of the 4 coils fail, the remaining three coil currents change via a novel distribution matrix such that the same opposing pole, C-core type, control fluxes as those of the un-failed bearing are produced. Magnetic flux coupling in the magnetic bearing core and the optimal current distribution helps to produce the same c-core fluxes as those of unfailed bearing even if one coil suddenly fails. Thus the magnetic forces and the load capacity of the bearing remain invariant throughout the failure event. It is shown that the control fluxes to each active pole planes are successfully isolated. A numerical example is provided to illustrate the new theory.

The Experiment of the persistent current operation characteristics using Bi-2223 HTS coil (Bi-2223고온 초전도 코일의 영구전류 운전특성 실험)

  • 최세용;나완수;김정호;주진호;하홍수;오상수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.291-293
    • /
    • 2002
  • In this paper, we fabricated a persistent current mode magnet using Bi-2223 HTS tapes. The coil system consists of double pancake magnet and a persistent current switch and jointed them with solder. Persistent current mode operation of the system was measured experimentally by the decay behavior of the current. We found that resistive component of the system including flux flow resistance lead the exponentially field decay with time.

  • PDF

SIMULTANEOUS MEASURING SYSTEM FOR PERMEABILITY AND RESISTIVITY OF MAGNETIC SHEET WITH DOUBLE COIL IMPEDANCE

  • Nonaka, Yoshihiro;Takeda, Kenichiro;Nakane, Hiroshi;Maeda, Takao
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.391-394
    • /
    • 1995
  • Simultaneous measuring system for permeability and resistivity of magnetic sheets is presented. In this system, the coil impedance is measured when a specimen is inserted between two coils. This system was applied to nickel sheets, iron-nickel alloys and a nickel film.

  • PDF

A Joining Method between HTS Double Pancake Coils (고온초전도 더블 팬케이크 코일들 사이의 접합 방법)

  • Sohn, Myung-Hwan;Sim, Ki-Deok;Kim, Seok-Ho;Kim, Hae-Jong;Bae, Joon-Han;Lee, Eon-Young;Min, Chi-Hyun;Seong, Ki-Chul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

Endovascular Treatment of Wide-Necked Intracranial Aneurysms : Techniques and Outcomes in 15 Patients

  • Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • Objective : It is technically difficult to treat wide-necked intracranial aneurysms by the endovascular method. Various tools and techniques have been introduced to overcome the related technical limitations. The purpose of this study was to evaluate the radiologic and clinical results of widenecked intracranial aneurysm treatment using the endovascular method. Methods : Fifteen aneurysms in 15 patients were treated by the endovascular method from October 2009 to August 2010. Seven patients presented with subarachnoid hemorrhage (SAH), seven patients had unruptured aneurysms, and one patient had an intracerebral hemorrhage and intraventricular hemorrhage due to an incompletely clipped aneurysm. The mean dome-to-neck ratio was 1.1 (range, 0.6-1.7) and the mean height-to-neck ratio was 1.1 (range, 0.6-2.0). We used double microcatheters instead of a stent or a balloon for the first trial. When we failed to make a stable coil frame with two coils, we used a stent-assisted technique. Results : All aneurysms were successfully embolized. Eleven aneurysms (73%) were embolized by the double microcatheter technique without stent insertion, and four aneurysms (27%) were treated by stent-assisted coil embolization. One case had subclinical procedure-related intraoperative hemorrhage. Another case had procedure-related thromboembolism in the left distal anterior cerebral artery. During the follow-up period, one patient (7%) had a recanalized aneurysmal neck 12 months after coil embolization. The recurrent aneurysm was treated by stent-assisted coil embolization. Conclusion : We successfully treated 15 wide-necked intracranial aneurysms by the endovascular method. More clinical data with longer follow-up periods are needed to establish the use of endovascular treatment for wide-necked aneurysm.

Characteristics of Evaporation Heat Transfer in a Small-Scale Cryogenic Heat Exchange System for the Utilization of LNG Cold Energy (LNG 냉열활용을 위한 초저온 열교환시스템의 축소모형에서 증발 열전달 특성)

  • Nam S. C.;Lee S. C.;Lee Y. W.;Sohn Y. S.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.25-33
    • /
    • 1998
  • The characteristics of evaporation heat transfer for the utilization of LNG cold energy was investigated experimentally using liquified nitrogen and a solution of ethylene-glycol and water under horizontal two-phase conditions in the small-scale equipment of a cryogenic heat exchange system. The inner tubes in the double pipe heat exchanger with 8 mm and 15 mm inner diameter and 6 m length were adopted as a smooth test tubes and enhanced tubes by means of wire-coil inserts. Heat transfer coefficients and Nusselt number for the test tube were calculated from measurements of temperatures, flowrates and pressures. The correlations in a power-law relationship of the Nusselt number, the Reynolds number and Prandtl number for heat transfer were proposed which can be available for design of cryogenic heat exchangers. The correlations showed heat transfer coefficients for the wire-coil inserts were much higher than those for the smooth tubes, increased by more than 2.5 ${\~}$ 5.5 times depending upon the equivalent Reynolds number. Form and length of cryogenic double pipe heat exchanger were proposed for applicable to the utilization of LNG cold energy.

  • PDF

The Design of Resonator for Miniaturization of Magnetic Resonance Wireless Power Transfer System (자기공진형 무선전력전송 시스템의 소형화를 위한 공진기 설계)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.163-169
    • /
    • 2016
  • In this paper, we miniaturized the loop and coil in magnetic resonance wireless power transfer(MR-WPT) system for application to the small mobile device. The proposed disk type double coil resonator was designed to cause resonance at 6.87 MHz. It is composed of thin copper on both-side of acrylic substrate structured 2 mm width, 1 mm pitch and 8 turns. The outer radius of spiral coil pattern is 9 cm. And the proposed loop was made of the copper wire 5 mm diameter of cross-section. The size of loop is 10 cm diameter. For resonance at 6.87 MHz, the capacitor with 3,300 pF was connected in series on the loop. We rearranged the resonators and organized several WPT systems which is rearranged by resonators. The highest transfer efficiency of miniaturized WPT system was 35.67 %. This proposed design of spiral double coil will contribute to make resonator smaller for appling small and thin mobile device.