1 |
Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, et al. : Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41 : 2247-2253, 2010
DOI
ScienceOn
|
2 |
Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, et al. : International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms : a randomised trial. Lancet 360 : 1267-1274, 2002
DOI
ScienceOn
|
3 |
Moret J, Cognard C, Weill A, Castaings L, Rey A : The "Remodelling Technique" in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Interv Neuroradiol 3 : 21-35, 1997
DOI
|
4 |
Raymond J, Roy D, Leblanc P, Roorda S, Janicki C, Normandeau L, et al. : Endovascular treatment of intracranial aneurysms with radioactive coils : initial clinical experience. Stroke 34 : 2801-2806, 2003
DOI
ScienceOn
|
5 |
Raymond J, Guilbert F, Roy D : Neck-bridge device for endovascular treatment of wide-neck bifurcation aneurysms : initial experience. Radiology 221 : 318-326, 2001
DOI
ScienceOn
|
6 |
Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, et al. : Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34 : 1398-1403, 2003
DOI
ScienceOn
|
7 |
Baxter BW, Rosso D, Lownie SP : Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms. AJNR Am J Neuroradiol 19 : 1176-1178, 1998
|
8 |
Broadbent LP, Moran CJ, Cross DT 3rd, Derdeyn CP : Management of neuroform stent dislodgement and misplacement. AJNR Am J Neuroradiol 24 : 1819-1822, 2003
|
9 |
Turjman F, Massoud TF, Sayre J, Viñuela F : Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils : a multivariate analysis. AJNR Am J Neuroradiol 19 : 1645-1651, 1998
|
10 |
Vallee JN, Pierot L, Bonafe A, Turjman F, Flandroy P, Berge J, et al. : Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils : predictors of immediate anatomic and clinical results. AJNR Am J Neuroradiol 25 : 298-306, 2004
|
11 |
Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN : Stents for intracranial aneurysms : the beginning of a new endovascular era? Neurosurgery 43 : 377-379, 1998
DOI
ScienceOn
|
12 |
Yun JH, Cho CS : Experiences of neuroform stent applications for ruptured anterior communicating artery aneurysms with small parent vessel. J Korean Neurosurg Soc 48 : 53-58, 2010
DOI
|
13 |
Lanzino G, Wakhloo AK, Fessler RD, Hartney ML, Guterman LR, Hopkins LN : Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms. J Neurosurg 91 : 538-546, 1999
DOI
|
14 |
Hope JK, Byrne JV, Molyneux AJ : Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR Am J Neuroradiol 20 : 391-399, 1999
|
15 |
Kwon OK, Kim SH, Kwon BJ, Kang HS, Kim JH, Oh CW, et al. : Endovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patients. AJNR Am J Neuroradiol 26 : 894-900, 2005
|
16 |
Kwon OK, Kim SH, Oh CW, Han MH, Kang HS, Kwon BJ, et al. : Embolization of wide-necked aneurysms with using three or more microcatheters. Acta Neurochir (Wien) 148 : 1139-1145; discussion 1145, 2006
DOI
ScienceOn
|
17 |
Levy DI, Ku A : Balloon-assisted coil placement in wide-necked aneurysms. Technical note. J Neurosurg 86 : 724-727, 1997
DOI
ScienceOn
|
18 |
De Keukeleire K, Vanlangenhove P, Defreyne L : Evaluation of a neck-bridge device to assist endovascular treatment of wide-neck aneurysms of the anterior circulation. AJNR Am J Neuroradiol 29 : 73-78, 2008
DOI
ScienceOn
|
19 |
Cloft HJ, Joseph GJ, Tong FC, Goldstein JH, Dion JE : Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms. AJNR Am J Neuroradiol 21 : 1312-1314, 2000
|
20 |
Debrun GM, Aletich VA, Kehrli P, Misra M, Ausman JI, Charbel F : Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary University of Illinois at Chicago experience. Neurosurgery 43 : 1281-1295; discussion 1296-1297, 1998
|
21 |
de Paula Lucas C, Piotin M, Spelle L, Moret J : Stent-jack technique in stent-assisted coiling of wide-neck aneurysms. Neurosurgery 62 : ONS414-ONS416; discussion ONS416-ONS417, 2008
|
22 |
Fernandez Zubillaga A, Guglielmi G, Viñuela F, Duckwiler GR : Endovascular occlusion of intracranial aneurysms with electrically detachable coils : correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 15 : 815-820, 1994
|
23 |
Gonzalez N, Sedrak M, Martin N, Vinuela F : Impact of anatomic features in the endovascular embolization of 181 anterior communicating artery aneurysms. Stroke 39 : 2776-2782, 2008
DOI
ScienceOn
|
24 |
Higashida RT, Smith W, Gress D, Urwin R, Dowd CF, Balousek PA, et al. : Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery : case report and review of the literature. J Neurosurg 87 : 944-949, 1997
DOI
ScienceOn
|