• 제목/요약/키워드: Distance protection

검색결과 531건 처리시간 0.026초

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

계단식 발파에 있어서 자유면 전.후방의 지반진동에 관한 연구 (A Study on the Ground Vibration of the Front and the Back Direction of the Free Face in the Bench Blasting)

  • 기경철;김일중
    • 화약ㆍ발파
    • /
    • 제20권2호
    • /
    • pp.21-31
    • /
    • 2002
  • We did bench blasting upon the natural rock which it's uniaxial compressive strength was about $1,420~1,476kgf/\textrm{cm}^2$. This is the results we inferred after measuring, analyzing the ground vibration velocity of the front and back direction from the free face of the bench blasting. We have to induce the square and cube root scaled equation and the general equation to guarantee confidence upon the data when analyzing the measurement data of the test blasting. The variable distance is in reverse proportion to the permitted ground vibration velocity. The shorter is the exploding point to a protection structure, the bigger is the reflection that the direction of the free face experts the ground vibration velocity, The ground vibration velocity front of the free face tends become reduced about 38~46% compare with back of the free face in the range that the permitted ground vibration velocity is 2.0~5.0mm/sec. In case of 2.0mm/sec, when a protection structure is within about 95m, the max. allowable charge weight per delay on positing front of the free face can be more used about 2.61 times than that on positing back of the free face, in case of 3.0mm/sec within about 78m more about 2.38 times, in case of 5.0mm/sec within 60m more about 2.10 times. In case of 2.0~5.0mm/sec when a protection structure is within about 200m front from the free face, the max. allowable charge weight per delay can become about 1.52 times than the case on back to the free face.

Performance Analysis of Spiral Axicon Wavefront Coding Imaging System for Laser Protection

  • Haoqi Luo;Yangliang Li;Junyu Zhang;Hao Zhang;Yunlong Wu;Qing Ye
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.355-365
    • /
    • 2024
  • Wavefront coding (WFC) imaging systems can redistribute the energy of an interference laser spot on an image plane sensor by wavefront phase modulation and reduce the peak intensity, realizing laser protection while maintaining imaging functionality by leveraging algorithmic post-processing. In this paper, a spiral axicon WFC imaging system is proposed, and the performance for laser protection is investigated by constructing a laser transmission model. An Airy disk on an image plane sensor is refactored into a symmetrical hollow ring by a spiral axicon phase mask, and the maximum intensity can be reduced to lower than 1% and single-pixel power to 1.2%. The spiral axicon phase mask exhibits strong robustness to the position of the interference laser source and can effectively reduce the risk of sensor damage for an almost arbitrary lase propagation distance. Moreover, we revealed that there is a sensor hazard distance for both conventional and WFC imaging systems where the maximum single-pixel power reaches a peak value under irradiation of a power-fixed laser source. Our findings can offer guidance for the anti-laser reinforcement design of photoelectric imaging systems, thereby enhancing the adaptability of imaging systems in a complex laser environment. The laser blinding-resistant imaging system has potential applications in security monitoring, autonomous driving, and intense-laser-pulse experiments.

지중송전케이블룡 디지털 거리계전 알고리즘 개선 (An Improvement of Digital Distance Relaying Algorithm on Underground Transmission Cables)

  • 하체웅;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권12호
    • /
    • pp.595-601
    • /
    • 2000
  • This paper describes the improvement method of distance relaying algorithm for the underground transmission cables. Distance relaying algorithms have been mainly developing to protect the overhead transmission lines than the underground cables. If the cable systems are directly protected using distance relaying algorithm developed for overhead line without any improvement, there will be really occurred many misoperation in cable systems, because the cable systems consist of the conductor, the sheath, several grounding method, cable cover protection units(CCPUs), and grounding wire. Accordingly, the complicated phenomena are occurred, if there is a fault in cable systems. Therefore, to develope a correct distance relaying algorithm, such cable characteristics should be taken into account. This paper presents the process to improve distance relaying algorithm which is now used. REal cable system was selected to establish modeling in EMTP and ATP Draw. It was discovered through the detailed simulation during the fault that the large error existed between impedance measured at the relay point and real impedance is due to the resistance of grounding wire in each grounding method. And also compensation factor obtained by the simulation is proposed in this paper. It is proved that the factor proposed can fairly improve the accuracy of impedance at the relay point. It is evaluated that the protective ability will be really much improved, if the algorithm proposed in this paper is applied for cable systems of utility.

  • PDF

산림기반 야생동식물보호구역 조경을 위한 기초연구 (A Preliminary Study on the Adjustment of Forest-based Wildlife Protection Area)

  • 장갑수
    • 한국조경학회지
    • /
    • 제36권1호
    • /
    • pp.62-69
    • /
    • 2008
  • This study was conducted in order to recommend forest-based wildlife protection areas in Chung-nam Province using several basic habitat conditions. The conditions used in this study were the forest patch size with the potential to keep wildlife animals safe, the distance from water sources, and the availability of food for wildlife. The fractal dimension index was also used to find the edge line dynamics, which can influence on habitat conditions for edge species. The natural conservation management indices including a forest map (indicating the level of forest age), a slope map, and an elevation map were used to find the forest patches with enough space for wildlife to live on. Water resources and their buffer areas were considered as factors to protect the space as an ecological corridor. Deciduous trees and trees mixed with deciduous trees and conifers were chosen to provide wildlife animals their food. In total, 525 forest patches were chosen and recommended for the wildlife protection area. Five of these forest patches were recommended as wildlife protection areas managed by the provincial government. The other 520 forest patches were recommended to protect local wildlife animals and be managed by each county or city. These forest patches were located around the Geum-buk and Geum-nam mountains, and the forest patches are important resources as habitats to keep wildlife in the area. An ecological network consists of these separate forest patches with the ecological integration. A fractal dimension index was used to divide forest patches into several categories in order to find how patches are shaped. The forest patches with longer edges or more irregular shapes have a much higher possibility of being inhabited by various types of edge species. Through comparison of the wildlife protection areas recommended in this study to the current wildlife protection areas, we recognized that the current wildlife protection areas need boundary adjustments in order for wildlife animals to survive by themselves with water sources and food.

Sensitivity analysis of input variables to establish fire damage thresholds for redundant electrical panels

  • Kim, Byeongjun;Lee, Jaiho;Shin, Weon Gyu
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.84-96
    • /
    • 2022
  • In the worst case, a temporary ignition source (also known as transient combustibles) between two electrical panels can damage both panels. Mitigation strategies for electrical panel fires were previously developed using fire modeling and risk analysis. However, since they do not comply with deterministic fire protection requirements, it is necessary to analyze the boundary values at which combustibles may damage targets depending on various factors. In the present study, a sensitivity analysis of input variables related to the damage threshold of two electrical panels was performed for dimensionless geometry using a Fire Dynamics Simulator (FDS). A new methodology using a damage evaluation map was developed to assess the damage of the electrical panel. The input variables were the distance between the electrical panels, the vertical height of the fuel, the size of the fire, the wind speed and the wind direction. The heat flux was determined to increase as the vertical distance between the fuel and the panel decreased, and the largest heat flux was predicted when the vertical separation distance divided by one half flame length was 0.3-0.5. As the distance between the panels increases, the heat flux decreases according to the power law, and damage can be avoided when the distance between the fuel and the panel is twice the length of the panel. When the wind direction is east and south, to avoid damage to the electrical panel the distance must be increased by 1.5 times compared to no wind. The present scale model can be applied to any configuration where combustibles are located between two electrical panels, and can provide useful guidance for the design of redundant electrical panels.

해상풍력발전기 직격뢰 보호용 1등급 바리스터 개발 (Development of class I surge protection device for the protection of offshore wind turbines from direct lightning)

  • 이건희;박재현;정경진;강성만;최승규;우정민
    • 풍력에너지저널
    • /
    • 제14권4호
    • /
    • pp.50-56
    • /
    • 2023
  • With the abnormal weather phenomena caused by global warming, the frequency and intensity of lightning strikes are increasing, and lightning accidents are becoming one of the biggest causes of failures and accidents in offshore wind turbines. In order to secure generator operation reliability, effective and practical measures are needed to reduce lightning damage. Because offshore wind turbines are tall structures installed at sea, the possibility of direct lightning strikes is very high compared to other structures, and the role of surge protection devices to minimize damage to the electrical and electronic circuits inside the wind turbine is very important. In this study, a varistor, which is a key element for a class 1 surge protection device for direct lightning protection, was developed. The current density was improved by changing the varistor composition, and the distance between the electrode located on the varistor surface and the edge of the varistor was optimized through a simulation program to improve the fabrication process. Considering the combined effects of heat distribution, electric field distribution, and current density on the optimized varistor surface, silver electrodes were formed with a gap of 0.5 mm. The varistor developed in this study was confirmed to have an energy tolerance of 10/350 ㎲, 50kA, which is a representative direct lightning current waveform, and good protection characteristics with a limiting voltage of 2 kV or less.

2019년 국내 사과와 배 화상병 대발생과 그 특징 (Outbreak of Fire Blight of Apple and Pear and Its Characteristics in Korea in 2019)

  • 함현희;이경재;홍성준;공현기;이미현;김현란;이용환
    • 식물병연구
    • /
    • 제26권4호
    • /
    • pp.239-249
    • /
    • 2020
  • 2019년 국내의 사과와 배에 화상병이 크게 발생한 원인을 파악하기 위하여 화상병 발생한 30개 과원을 대상으로 각각의 발생 상황과 농가 면담을 통해 경종적 특징 등을 조사하였다. 화상병은 이미 감염된 지 2년 이상 오래 된 과원에서 대부분 발생하였는데, 이런 원인은 (1) 농가가 병 증상을 정확히 알지 못하여 농작업과 방화곤충 등을 통해 과원 내에서 퍼지게 되고, (2) 방화곤충이나 농작업자 등에 의해 처음 발생 과원에서 주변 과수원으로 확산되었고, (3) 동일 경작자 또는 공동 농작업자에 의해 근거리 또는 원거리로 확산된 것이라고 추정할 수 있다. (4) 이런 일련의 과정이 새롭게 확산된 지역에서 반복되다가 농가들이 화상병을 알게 되면서 신고가 증가한 것이 2019년 화상병 대발생의 일련의 원인이라고 추정할 수 있었다. 국내에서 화상병 확산을 최소화하기 위해서는 조기진단을 위한 철저한 농업인 교육과 무병징 식물체에서도 화상병균 진단이 가능한 정량적 검출기술이 요구되고 있다. 또한 큰 열매를 주로 생산하는 국내 재배법에 적합한 약제방제 체계 개발이 필요하다. 화상병 방제에서 가장 중요한 가지의 궤양 증상, 묘목, 양봉장 등의 전염원 관리를 위해서 과원별 병원균의 분자역학연구를 통해 정확한 확산경로를 구명할 것을 제안한다.

추적레이다에 의한 인체에 대한 영향(HERP) 및 전자파 간섭(EMI) 분석

  • 김대오;신한섭;김태형;이효근
    • 항공우주기술
    • /
    • 제4권1호
    • /
    • pp.239-246
    • /
    • 2005
  • 본 논문에서는 추적레이다의 고출력 전자파에 의한 인체에 대한 영향(HERP)과 추적레이다 자체 장비에 대한 영향 및 동일한 C-Band 주파수 대역 사용으로 발생하는 기상레이다에 대한 전 자파 간섭(EMI) 분석을 실시하여 장비 설치 구역 내 통제가 가능한 인원(Controlled Personnel) 과 통제가 불가능한 인원(Uncontrolled Personnel)에 대한 최소 접근 제한거리를 산출하고 추적레이다 자체 장비에 대한 영향 및 동일한 주파수 대역 사용으로 발생하는 추적레이다와 기상레이다간의 전자파 간섭(EMI)을 해소하기 위한 방안을 제시하였다.

  • PDF

기존선 속도향상을 위한 ETCS Level 1 구축방안 연구 (A study of eatablishing ETCS Level 1 to speed up conventional lines)

  • 윤용기;정락교;김채덕
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.666-670
    • /
    • 2011
  • ATS(Automatic Train Stop)s are is effected by track environment, signal distance and train braking distance. So onboard signaling systems such as ATP(Automatic Train Protection) are installed on conventional lines by some train operation companies. With the mixed signalling, the onboard signaling system is overlaid on a conventional line with ATS, it is possible to run the line with conventional trains and ATP trains and to use the advantages of ATP(higher speed or more trains on the line). This paper includes guidelines a mixed signalling(ETCS and ATS) system architecture, operation concepts and infill balise installation.

  • PDF