1 |
J. Lee, Numerical analysis of how ventilation conditions impact compartment fire suppression by water mist, Ann. Nucl. Energy 136 (2020).
|
2 |
J. Lee, J. Moon, Numerical analysis of the effect of horizontal distance between a water mist nozzle and ignition source on reduction in heat release rate, Ann. Nucl. Energy 144 (2020).
|
3 |
C. Gong, L. Ding, H. Wan, J. Ji, Z. Gao, L. Yu, Spatial temperature distribution of rectangular n-heptane pool fires with different aspect ratios and heat fluxes received by adjacent horizontal targets, Fire Saf. J. 112 (2020).
|
4 |
J.M. Souil, P. Joulain, E. Gengembre, Experimental and theoretical study of thermal radiation from turbulent diffusion flames to vertical target surfaces, Combust. Sci. Technol. 41 (1-2) (1984) 69-81.
DOI
|
5 |
F. Tang, H. Qing, W. Jennifer, Effects of crosswind and burner aspect ratio on flame characteristics and flame base drag length of diffusion flames, Combust. Flame 200 (2019) 265-275.
DOI
|
6 |
J. Ji, B. Li, H. Wan, L. Ding, Z. Gao, Gas temperature rise and flame length induced by two buoyancy-controlled propane burners aligned parallel to the cross wind, Int. J. Therm. Sci. 152 (2020).
|
7 |
B. Li, H. Wan, Z. Gao, J. Ji, Experimental study on the characteristics of flame merging and tilt angle from twin propane burners under cross wind, Energy 174 (2019) 1200-1209.
DOI
|
8 |
R. McDermott, K. McGrattan, J. Floyd, A simple reaction time scale for under-resolved fire dynamics, Fire Saf. Sci. 10 (2011) 809-820.
DOI
|
9 |
J. Lee, F. Joglar, U. Farradj, A. Ratchford, Fire risk assessment to develop a compliance strategy for sample redundant electrical panels at a nuclear power plant based on deterministic fire protection requirements, Prog. Nucl. Energy 128 (2020).
|
10 |
U.S. NRC, Fire Protection for Operating Nuclear Power Plants (Regulatory Guide 1.189), United States Nuclear Regulatory Commission, Washington, DC, 2009.
|
11 |
J. Lee, Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening, Nucl. Eng. Technol. 51 (2) (2019) 410-423.
DOI
|
12 |
U.S. NRC, EPRI/NRC-RES Fire PRA Methodology for Nuclear Power Facilities Detailed Methodology (No. NUREG/CR-6850, EPRI 1011989 Final Report), vol. 2, U.S. Nuclear Regulatory Commission, Rockville, MD, USA, 2005.
|
13 |
U.S. NRC, "Nuclear Power Plant Fire Modeling Analysis Guidelines", NUREG1934, United States Nuclear Regulatory Commission, Washington, D.C., 2012.
|
14 |
U.S. NRC, Verification and Validation of Selected Fire Models for Nuclear Power Plant Applications - Final Report (No. NUREG-1824, Supplement 1, U.S. Nuclear Regulatory Commission, Washington, D.C., USA, 2016.
|
15 |
D.S. Kinden, Experimental Study of the Effect of Froude-Number Scaling on Radiation, Master Thesis, Western Norway University of AppliedSciences, Norway, 2019.
|
16 |
S.H. Yun, C.H. Hwang, Changes in fire characteristics according to the distance between the fire source and sidewall in a reduced-scale compartment, Fire Sci. Eng. 33 (1) (2019) 50-59.
|
17 |
C.H. Lin, Y.M. Ferng, W.S. Hsu, B.S. Pei, Investigations on the characteristics of radiative heat transfer in liquid pool fires, Fire Technol. 46 (2) (2010) 321-345.
DOI
|
18 |
R. Fleury, Evaluation of Thermal Radiation Models for Fire Spread between Objects, Master Thesis, University of Canterbury, Australia, 2010.
|
19 |
S.C. Kim, K.Y. Lee, A. Hamins, Energy balance in medium-scale methanol, ethanol, and acetone pool fires, Fire Saf. J. 107 (2019) 44-53.
DOI
|
20 |
M.E. Klassen, J.P. Gore, Structure and Radiation Properties of Pool Fires, NIST GCR 94-651, National Institute of Standards and Technology, Gaithersburg, MD, USA, 1994.
|
21 |
M.M. Barsim, M.A. Bassily, H.M. El-Batsh, Y.A. Rihan, M.M. Sherif, Froude scaling modeling in an Atrium Fire equipped with natural and transient forced ventilation, Int. J. Vent. 19 (3) (2020) 201-223.
DOI
|
22 |
N. Iqbal, M.H. Salley, "Fire Dynamics Tools (FDTs): Quantitative Fire Hazard Analysis Methods for the US Nuclear Regulatory Commission Fire Protection Inspection Program" Final Report, 2006.
|
23 |
J. Ji, G. Fanliang, Q. Tingting, Experimental and theoretical research on flame emissivity and radiative heat flux from heptane pool fires, in: Proceedings of the Combustion Institute, 2020.
|
24 |
Korea Meteorological Administration Weather Data Service. https://data.kma.go.kr/climate/StatisticsDivision/selectStatisticsDivision.do?pgmNo=158. (Accessed 16 June 2021) accessed.
|
25 |
J.A. Milke, Smoke Control by Mechanical Exhaust or Natural venting." SFPE Handbook of Fire Protection Engineering, Springer, New York, NY, 2016, pp. 1824-1862.
|
26 |
J.H. Quintiere, Scaling applications in fire research, Fire Saf. J. 15 (1) (1989) 3-29.
DOI
|
27 |
A.T. Modak, Thermal radiation from pool fires, Combust. Flame 29 (1977) 177-192.
DOI
|
28 |
J. Lee, K.A. Sallam, Column thickness variation of 100-mm liquid in still air, Atomization Sprays 27 (1) (2017).
|
29 |
Nobuyuki Otsu, A threshold selection method from gray-level histograms, IEEE transactions on systems, man, and cybernetics 9 (1) (1979) 62-66.
DOI
|
30 |
K. McGrattan, S. Hostikka, R. McDermott, J. Floyd, C. Weinschenk, K. Overholt, Fire Dynamics Simulator User's Guide, NIST special publication1019.6, 2013.
|
31 |
G. Heskestad, Fire plumes, flame height, and air entrainment, in: SFPE Handbook of Fire Protection Engineering, Springer, New York, NY, 2016, pp. 396-428.
|
32 |
U.S. NRC EPRI/NRC-RES, Methodology for Modeling Transient Fires in Nuclear Power Plant Fire Probabilistic Risk Assessment (NUREG-2233, EPRI 3002018231), 2020.
|
33 |
H.S. Han, C.H. Hwang, C.B. Oh, D. Choi, S. Lee, Comparison of the flame height of pool fire according to combustion models in the FDS, Fire Sci. Eng. 32 (3) (2018) 42-50.
DOI
|
34 |
G. Ha, W.G. Shin, J. Lee, Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment, Nucl. Eng. Technol. 53 (4) (2021) 1157-1166.
DOI
|