• Title/Summary/Keyword: Disaster safety program

Search Result 201, Processing Time 0.036 seconds

An Analysis of Probabilistic Seismic Hazard in the Korean Peninsula - Probabilistic Peak Ground Acceleration (PGA) (한반도의 확률론적 지진위험도 분석 - 확률론적 최대지반가속도(PGA))

  • Kyung, Jai-Bok;Kim, Min-Ju;Lee, Sang-Jun;Kim, Jun-Kyung
    • Journal of the Korean earth science society
    • /
    • v.37 no.1
    • /
    • pp.52-61
    • /
    • 2016
  • The purpose of the study was to create a probabilistic seismic hazard map using the input data that reflected the seismo-tectonic characteristics of the Korean Peninsula by applying USGS program (Harmsen (2008). The program was partly modified for the purpose of this study. The uncertainty of input parameters given by specialists was reflected in calculating the seismic hazard values by logic tree method. The general pattern of PGA was quite sensitive and similar to the shape of areal source. The probabilistic seismic hazard map showed the contour distribution of peak acceleration (%g) with 10% probability of exceedance in 5, 10, 20, 50, 100, 250, and 500 years. The result showed that the peak ground acceleration (PGA) values of the northern peninsula were almost half values of the southern peninsula except Hwanghae province. The general trend of the hazard map extended in the direction of NW-SE from Whanghae province to south-eastern regions of the peninsula. The values in northern part of Kangwon province were relatively lower than other areas in the southern peninsula. The maps produced through this study are considered valuable in regulating the seismic safety of the major facilities in the Korean Peninsula.

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

A Study on Response System of Marine Pollution Accident by Chemicals in United States (화학물질 해양오염사고에 대한 미국의 방제체제 연구)

  • Choi, Jong-Wook;Lee, Seung-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.61-67
    • /
    • 2007
  • With an entering into force of OPRC-HNS started in June 14th 2007, establishment of response system in a nationwide scale to take care of accidents is required to respond rapidly and effectively. This necessities drove us to analyze national contingency plan for chemicals including national response system against accidents, which is in operation in the US. Main characteristics of the system are well described as an integrated incident command system with a cooperation of responsibilities facilities, manpower, and technical support. In addition, state anψor local authorities tend to have responsibilities on management of disaster with its response activities. Polluters are also charged to pay expenses 3 times expensive provided state or local authorities are conducted. In general, response activities are conducted by private sectors. However, the government will take action with Superfund if the response capacity is over than the polluters can. However, safety are regarded as a primary factor to be considered in the response activities, and try not to recover any pollutants. Personals belonging to USCG and EPA are required to complete specialized courses to promαe professional skills, and are also welcomed to participate in "certification program"

  • PDF

A Study on The Possibility of Flash Fire of Combat System by Kinetic Energy Ammunitions (운동에너지탄에 의한 전투시스템의 순간화재 발생가능성에 대한 연구)

  • Park, Young Ju;Lee, Eun Min;Lee, Hae Pyeong;Hwang, Me Jung;Lee, Chang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • This study analyzed various possibilities of flash fire which could occur in a variety of combats, in order to predict that of flash fire of combat system armor using Autodyn program. The possibility was judged by the temperature distribution of fuels, which was caused by the impact of parts of fuel systems through an armor, in the event of getting shot by external ammunition. Diverse variables could affect the possibility of flash fire: external ammunition(Type A: penetration 570 mm, Type B: penetration 410 mm), fuels(Gasoline, Diesel, Kerosene), the thickness of an armor(100, 200, 300, 400, 500 mm), the gap of a fuel tank and an armor(45, 95, 145, 195, 245, 295 mm). As a result, when an armor was 20 mm think, the temperature of 3 fuels ranged like this: Gasoline 372~387 K, Diesel 442~408 K, Kerosene 384~395 K. Although they made a little difference among them, they all didn't reach their ignition points. When an armor was 200 mm think, each fuel reached the maximum temperature, not reaching its ignition points as well. The thicker an armor was, the lower the temperature got. When Type B ammunition was used, the temperature of fuels went up 19~59 K higher than Type A was used. In the case that the gap of fuel tank and an armor was 20 mm thick, the temperature distribution of Gasoline showed 389~450 K, the maximum temperature appeared in the gap of 145 mm, and the minimum temperature 295 mm. For Type B, the temperature distribution of fuels ranged 386~401 K, the maximum temperature appeared in the gap of 245 mm, and the minimum temperature 45 mm. There was no significant difference between two cases, and neither of them reached its ignition point. Accordingly, as the tested fuels of combat systems didn't reach their ignition points, it is thought that the possibility of flash point of an armor is low.

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.

Awareness of disaster and post traumatic stress disorder in occupational therapy students (재난 및 외상 후 스트레스장애에 대한 작업치료 전공자의 인식조사)

  • Hong, Young-Ho;Cho, Su-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.539-547
    • /
    • 2017
  • This study examined the perception of disasters and post-traumatic stress disorder in occupational therapy majors to provide the basic data necessary for future occupational therapy. A questionnaire survey was conducted on 545 students in occupational therapy departments of three year and four year universities. The frequency of the questionnaire was calculated by frequency analysis using the SPSS 19.0 win program. A chi-squared test was conducted to verify the analyzed questionnaire data. The reliability of the questionnaire in this study showed a Cronbach' alpha value of 0.891. According to the survey results, approximately 20% of learners who majored in occupational therapy were unaware of the symptoms, developmental mechanism, and diagnostic criteria of post-traumatic stress disorder(PTSD). Knowledge of the underlying causes of psychological symptoms, such as post-traumatic stress disorder as well as physical damage through industrial accidents, was found to be 2.92 on the Likert 5-point scale. To be effective in rehabilitation treatment, the degree of the approach to education from the viewpoint of occupational therapy is important enough to be recognized as 3.90 on the Likert 5-point scale. The Pearson correlation coefficient for the need for education on disasters was higher than the correlation with the awareness of disasters.

Reliability Analysis of Access Door Opening Force Measured with a Digital Force Gauge of a Pressurized Smoke Control Zone and Presentation of Optimum Conditions for the Opening Force (디지털 측정기로 측정된 급기가압 제연구역의 출입문 개방력에 대한 신뢰성 분석 및 최적 조건 제시)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.468-473
    • /
    • 2016
  • The aim of this study was to measure the opening force of an access door of a pressurized smoke control zone and verify the reliability of the opening force. For the access door opening force, the opening load of the access door was measured before and after pressurized air had entered the smoke control zone. The reliability of the measured values was verified using the Anderson Darling's statistical analysis method of the Minitab Program. Because the analyzed P values were greater than 0.05 except for some floors before and after the operation of the smoke control equipment, the opening force was found to have 95% reliability. The normal distribution of the measured values showed no relationship with the operation of the smoke control equipment and the precision of the force gauge was believed to be reliable. The major factors for the optimal design of the pressurized smoke control equipment include the precision and reliability of the force gauge, the correct posture of the measuring person, and the same conditions for access doors. Therefore, a digital force gauge is believed to be suitable for measuring the opening force of the access door of a pressurized smoke control zone. In addition, standardization of the posture of a measuring person, the setup of the initial opening force of an access door, etc., are major variables for effective measurements of the door opening force of an access door.

Empirical Study on Injury Management System of Fire-Fighting Officer (소방공무원의 공상관리제도에 대한 실증연구)

  • Kwon, Seol A;Oh, Myeong Keun;Lee, Ju Ho;Lee, Min-Kyu;Park, Sang Ho;Hyeon, Seung Hyo;Ryu, Sang Il
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.114-125
    • /
    • 2019
  • The frequency of official injury of fire-fighting officers exposed to an extreme situation in disaster areas has been continuously increased. In spite of increase of injury, procedures of injury approval are complex, so the working environment of fire-fighting officers is very poor in terms of safety management. This study was, therefore, conducted to provide basic data for improvement of the injury management system for fire-fighting officers, by empirically analyzing the system for those in Busan city. The findings of the empirical analysis are as follows: first, the frequency of injury experienced by them is higher than that of other occupations; second, application for injury is not actively made; third, fire-fighting officers should bear the expense if injury is approved. On the basis of such an analysis on actual conditions, an analysis on policy factors for improving the injury management system shows; first, various high-risk matters should be considered in the review of application for injury, for improvement factors of the application for injury, while it is necessary to extend the benefit and support project for injured officers, for operation improvement factors of the injury management system, and the compensation act should be improved, for the improvement factors of the injury system. Second, it is urgent to develop damage prevention and coping education program for improving the injury management system. In addition, the simplification of administrative procedures of application for injury and the extension of benefit and support project for injured officers should be realized as soon as possible, moreover, the enhancement of directors' interest and support is also required.

The Improvement Measures for the Establishment of Emergency Management System in Private Security (위험사회의 전개에 따른 민간경비 산업의 대응과제 - 위기관리를 중심으로)

  • Park, Dong-Kyun
    • Korean Security Journal
    • /
    • no.10
    • /
    • pp.103-125
    • /
    • 2005
  • Hazard are defined here as threat to life, well-being, material goods and environmental from the extremes of natural processes or technology. The challenges of natural and technology in increasing the exposure of people and property to risk pose a dilemma for any government seeking the fullest protection for its people and their property. As society progresses and as technology improves and becomes ever more intricate and far reaching, the human species is confronted with increasingly diverse and numerous catastrophic events. Not so infrequently, unfortunately, the impact of either a man-made or natural disaster is compounded by the fact that policy makers have neither prepared themselves or the public to respond appropriately to a disaster once the tragedy has struck. Many concerns have been raised for importance of emergency management after 1990's numerous urban disasters in Korea. Emergency management is the discipline and profession of applying science, technology, planning, and management to deal with extreme events that can injure or kill large numbers of people, cause extensive damage to property, and disrupt community life. When the primary function of private security is to protect lives and property of clients, emergency management should be included in the security service and many countermeasures should be carried out for that purpose. The purpose of this study is to establish ways and means needed to improve the private security emergency management system in Korea. This study is spilt into four chapters. Chapter I is the introduction part. Chapter II introduces the reader to a private security and emergency management theory, and Chapter III deals with the establishment of an effective emergency management system in Korea private security, Chapter IV is a conclusion. Policy makers and private security industry employers in Korea has not concerned with the importance of training and education by lack of recognition and has been passive about qualified guards. And the authorities supervising and the administrating the guards has not recognized the importance of private security and has neglected the training of the guards. In theses contexts, private security should develop and maintain a educational program of emergency management to meet their responsibilities to provide the protection and safety of the clients. Today's modern corporate security director, is, first of all, a competent, well-rounded business executive and, second, a 'service expert'. And, emergency management personnel in private security industry need continuous training.

  • PDF

The research for the yachting development of Korean Marina operation plans (요트 발전을 위한 한국형 마리나 운영방안에 관한 연구)

  • Jeong Jong-Seok;Hugh Ihl
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.899-908
    • /
    • 2004
  • The rise of income and introduction of 5 day a week working system give korean people opportunities to enjoy their leisure time. And many korean people have much interest in oceanic sports such as yachting and also oceanic leisure equipments. With the popularization and development of the equipments, the scope of oceanic activities has been expanding in Korea just as in the advanced oceanic countries. However, The current conditions for the sports in Korea are not advanced and even worse than underdeveloped countries. In order to develop the underdeveloped resources of Korean marina, we need to customize the marina models of advanced nations to serve the specific needs and circumstances of Korea As such we have carried out a comparative analysis of how Austrailia, Newzealand, Singapore, japan and Malaysia operate their marina, reaching the following conclusions. Firstly, in marina operations, in order to protect personal property rights and to preserve the environment, we must operate membership and non-membership, profit and non-profit schemes separately, yet without regulating the dress code entering or leaving the club house. Secondly, in order to accumulate greater value added, new sporting events should be hosted each year. There is also the need for an active use of volunteers, the generation of greater interest in yacht tourism, and the simplification of CIQ procedures for foreign yachts as well as the provision of language services. Thirdly, a permanent yacht school should be established, and classes should be taught by qualified instructors. Beginners, intermediary, and advanced learner classes should be managed separately with special emphasis on the dinghy yacht program for children. Fourthly, arrival and departure at the moorings must be regulated autonomically, and there must be systematic measures for the marina to be able, in part, to compensate for loss and damages to equipment, security and surveillance after usage fees have been paid for. Fifthly, marine safety personnel must be formed in accordance with Korea's current circumstances from civilian organizations in order to be used actively in benchmarking, rescue operations, and oceanic searches at times of disaster at sea.