• 제목/요약/키워드: Digital radiography(DR)

검색결과 89건 처리시간 0.024초

Image J를 활용한 뼈의 노화도 예측법 (Prediction of Bone Aging by Adapting Image J)

  • 정홍문;원도연;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.63-67
    • /
    • 2012
  • Calcium density in human bones decreases as people are getting older due to the interior or exterior environmental factors. Bone aging forms osteoporosis. And this can bring out various spine fractures which develops a complications. Thus the prediction of seniliy is one of the important factors in spine diseases. Once spine aged, diverse fractures occur such as compression fracture and micro fracture. Side images of the spine by the digital radiography (DR) were prepared, and pixel arbitrary unit with Image J was measured from one spot in the lumbar bone part. By calculating pixel arbitrary unit of the simple contrast, it was obtained that the value of pixel arbitrary unit decreased as seniliy of bones increased. By simply applying Image J to the seniliy of patient's spine, the seniliy of bones predicts the level of danger with only digital radiography(2D) image. consequently we show that Image J value of pixel arbitrary unit index for predicts the level of precaution of osteoporosis patient.

  • PDF

DR(Digital Radiography)에서 PCXMC 2.0을 이용한 Kerma와 다목적 선량계, 유리선량계의 선량비교를 통한 흡수선량 평가 시 유리선량계의 유용성에 관한 연구 (A Study on the Usefulness of Glass Dosimeter in the Evaluation of Absorbed Dose by Comparing the Doses of Multi-purpose Dosimeter and Glass Dosimeter Using Kerma with PCXMC 2.0 in DR(Digital Radiography))

  • 황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.292-299
    • /
    • 2017
  • 방사선 방호는 결정적 영향을 방지하고 확률적 영향을 최소화하는데 목적이 있다. 결정적 영향과 확률적 영향을 과대평가하면 미래에 일어날 위험성에 대해 잘못된 평가를 내릴 수 있기 때문에 이들의 기본량인 흡수선량의 정확한 평가가 특히 중요하다. 본 연구는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0을 이용하여 Kerma를 측정하고, 다목적 선량계 및 유리선량계를 이용하여 나타난 선량을 비교하여 정확한 흡수선량을 평가하는 것에 목적을 두었다. 실험은 부위를 두개부, 복부, 골반부로 정하였고 Kerma는 몬테카를로 시뮬레이션을 기반으로 한 PCXMC 2.0로 측정하였다. 흡수선량은 다목적 선량계와 유리선량계로 측정하였다. 그 결과 PCXMC 2.0, 다목적 선량계, 유리선량계에서 두개부, 복부, 골반부 모두 PCXMC 2.0, 다목적 선량계, 유리선량계 순으로 선량 차이가 크게 났으며, 다목적 선량계는 Kerma에 더 가까운 값을 나타냈다. 결과적으로 실제 흡수선량 측정은 유리선량계가 가장 유리하다는 것을 알 수 있었다.

Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구 (Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR))

  • 황준호;정재호;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구는 진단용 검출기가 결함이 발생하는 경우 환자의 방사선 피폭과 영상의 화질에 영향을 줄 수 있다는 점에 착안하여 실험을 진행하였고 선량분석을 통해 검출기 성능을 신호 대 잡음비와 대조도 대 잡음비로 평가하였다. 선량계, 조직등가팬텀을 이용해 흡수선량과 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 실험방법은 팬텀 후면에 부착하여 나온 선량 값과 검출기 뒤에 부착한 선량 값이 일치하는지를 비교하였고 두개부 흉부 복부의 조건을 각각 75 kVp 25 mAs, 110 kVp에 8 mAs, 80 kVp에 20mAs로 설정하고 검사하였다. 그 결과 검출기의 뒤쪽에 부착한 선량값은 0.004 mGy, 0.006 mGy, 0.003 mGy로 나타났고, 팬텀 후면은 0.006 mGy, 0.016 mGy, 0.017 mGy로 차이가 있었다. 두 값을 일치시키기 위해서 조건이 증가하였고 신호 대 잡음비와 대조도 대 잡음비는 88.32, 88.10, 4.09, 1.63, 87.94, 79.97에서 93.87, 93.75, 4.91, 4.03, 92.02, 84.92로 증가하였다. 본 연구를 통해 검출기가 노후화 되는 경우 기기의 수명단축과 환자의 선량증가의 원인이 되었으며 또한 영상화질의 개선효과도 미비하다는 것을 알 수 있었다.

디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가 (Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR))

  • 최지안;황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권8호
    • /
    • pp.276-283
    • /
    • 2019
  • 본 연구는 자동노출제어장치(Automatic Exposure Control, AEC)와 수동노출 이용 시 입사표면선량(Entrance Surface Dose, ESD)과 Entropy를 분석하여 자동노출제어장치의 유용성에 대해 알아보고자 하였다. 실험방법은 Skull, Chest, Abdomen, Pelvis 부위에 대하여 란도팬텀(Rando Phantom)에 반도체 선량계를 위치시켜 선량을 측정하였고, 동시에 획득한 DICOM(Digital Imaging and Communications in Medicine) 파일을 Matlab으로 Entropy 분석을 하였다. 그 결과 자동노출제어장치 이용 시 모든 부위의 입사표면선량이 수동노출보다 낮았고 Entropy 수치는 높았으며, paired t-test는 p<0.05로 유의한 차이가 있음을 알 수 있었다. 결론적으로 자동노출제어장치의 사용은 X선 검사 시 발생할 수 있는 불필요한 방사선량과 정보의 손실량을 줄여서 피폭선량과 영상 화질의 최적화에 기여할 수 있는 유용한 방법이 될 수 있다.

CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구 (Baseline Correction in Computed Radiography Images with 1D Morphological Filter)

  • 김용권;류연철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

DR환경에 따른 일반촬영 검사의 시스템 변화에 관한 연구 (Evaluation of image in the center line of digital radiography)

  • 정성운;임청환
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2014
  • 본 연구는 Film System의 경우 카세트를 사용하여 환자검사부위와 tube 중심선속, 카세트의 중심이 맞았지만 디텍터의 경우 $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$ 고정형으로써 디텍터의 중심과 tube의 중심선속, 환자의 검사부위가 맞지 않은체로 검사가 이루어지는 경우가 있어, 디지털 방사선장비에서 중심선속에 따른 화질의 변화를 파악하여 Tube의 중심선속과 환자와의 중심선속 일치에 따른 중요성을 제시하고자 한다.

  • PDF

디지털방사선 환경에서 흉부 후.전방향 검사 시 심장과 심흉비 확대에 관한 연구 (A Study of Magnification of Cardiac Size and Cardiothoracic Ratio on Chest Posteroanterior Projection in Digital Radiography System)

  • 주영철;임청환
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.195-196
    • /
    • 2014
  • 현재 디지털방사선 환경으로 변화하고 있는 추세에 과거 필름-스크린 방식에서 사용되던 흉부 후 전 방향 검사 시 초점 영상 수신부 간의 거리가 디지털방식의 장비에도 여전히 적용되고 있다. 이에 본 연구에서는 3개의 DR장비에서 각 영상수용체의 제조특성을 고려하였을 때 실제 심장 및 심흉비의 확대정도에 대해 알아보고, 임상에서 DR 장비를 이용한 Chest PA 검사 시 심장 및 심흉비의 확대도에 대한 정보를 제공하고자 한다.

  • PDF

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구 (The study for electric readout of X-ray signal using MOSFET)

  • 박성광;강영수;서지현;박지군;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

금속 내부의 이물질 검출 향상을 위한 X-ray 영상 보정 모델 (X-ray Image Correction Model for Enhanced Foreign Body Detection in Metals)

  • 김원
    • 한국융합학회논문지
    • /
    • 제10권10호
    • /
    • pp.15-21
    • /
    • 2019
  • 자외선보다 파장이 짧은 X-선은 투과력이 매우 좋아 산업 분야 및 의료분야에 융합되어 많이 사용되고 있다. 특히 산업분야에서는 비파괴 검사 장비인 x-ray를 이용하여 금속과 같은 제품의 생산 과정에서 발생할 수 있는 금속 내부의 이물질에 검출에 대한 연구가 다양하게 이루어지고 있는 실정이다. X-ray 영상 이미지를 디지털 방식으로 획득하는 DR(Digital Radiography) 방사선 촬영 방식의 확산으로 디텍터의 사용이 활발해지고 있으나 내부의 센서 잡음 및 감도에 따라 이물질 검출이 불가능한 경우도 발생하고 있다. 금속 제품을 생산할 경우 이물질의 혼입으로 생산 제품의 불량률이 높아질 수 있기에 정확한 검출이 필요하다. 이에 본 논문에서는 금속 내부의 이물질과 같은 결함 검출의 효율을 향상시키기 위하여 획득한 X-ray 이미지의 보정 모델을 제안한다. 제안 모델을 통하여 금속 제품 생산 공정의 불량 검출에 적용하면 제품 결함의 검출을 정확하고 신속하게 처리할 수 있을 것으로 기대된다.