• Title/Summary/Keyword: Digital Switching Function

검색결과 85건 처리시간 0.032초

시뮬레이터 탑재형 디지털 여자시스템 기능검증 시험에 관한 연구 (A Study of Function Verification of Digital Excitation System with Real Time Simulator)

  • 류호선;신만수;이주현;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1191-1192
    • /
    • 2011
  • We released new triple redundant digital excitation system with real time generator-turbine simulator. One of its great merits is the real time generator-turbine simulator when it was compared with the other products. If excitation system is tripped by unexpected faults, Maintenance man can do easily performance test of digital excitation control board, sequence relay and thyristor switching device of phase controlled rectifier without manufacturer's support. For the verification of this system, It was tested with an actual excitation system implemented on 5kVA M-G Set. After finishing the tests, the trial product will be installed and operated at a 500MW thermal power plant.

  • PDF

DVD 영화관 관리시스템 설계 및 구현 (Design and Implementation of DVD cinema Management System)

  • 송은지
    • 디지털콘텐츠학회 논문지
    • /
    • 제10권2호
    • /
    • pp.209-216
    • /
    • 2009
  • 최근 디지털 기술이 발달됨에 따라 소비자는 보다 선명한 영상과 생동감 있는 음질로 영화를 관람하고자하는 욕구가 발생하여 비디오방이나 일반 영화관 대신에 DVD 영화관의 이용이 증가하고 있는 추세이다. 현재의 DVD 영화관에서는 단순히 상영시간에 맞추어 이용요금 계산 기능만을 가진 관리 시스템을 지니고 있다. 본 논문에서는 보다 효율적인 DVD 영화관 관리시스템을 제안한다. 특히, 여기서 제안하는 시스템은 패킷전송 기술을 이용해서 DVD 영화관에서 긴급한 상황이 발생했을 때 신속하게 대처할 수 있는 특징을 갖고 있다. 그 외 판매하는 물품관리, 신규 DVD 영화 관리와 등록이 가능하도록 했으며 관리자의 효율적인 업무를 도모하고 DVD 영화관 이용객과 원활한 양방향 커뮤니케이션이 가능하도록 하였다.

  • PDF

고주파 비대칭 PWM 3상 교류초퍼 (HIGH-FREQUENCY APWM THREE-PHASE AC CHOPPER)

  • 김한성;최규하;김용주;이근하;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.535-539
    • /
    • 1989
  • A high-frequency asymmetrical PWM control technique is proposed which can improve the input power factor of ac chopper and also suppress its harmonic contents of currents at both its input and load sides and the acoustic noises by its switching semiconductor devices. The ideal switching function for the proposed technique is derived and hence converted into asymmetrical PWM pattern for practical implementation of ac voltage regulator. Also the various power circuits of three phase AC choppers are suggested. The theoretical characteristics of the proposed PWM technique are investigated by digital simulation.

  • PDF

Effect of Channel Length in LDMOSFET on the Switching Characteristic of CMOS Inverter

  • Cui, Zhi-Yuan;Kim, Nam-Soo;Lee, Hyung-Gyoo;Kim, Kyoung-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권1호
    • /
    • pp.21-25
    • /
    • 2007
  • A two-dimensional TCAD MEDICI simulator was used to examine the voltage transfer characteristics, on-off switching properties and latch-up of a CMOS inverter as a function of the n-channel length and doping levels. The channel in a LDMOSFET encloses a junction-type source and is believed to be an important parameter for determining the circuit operation of a CMOS inverter. The digital logic levels of the output and input voltages were analyzed from the transfer curves and circuit operation. The high and low logic levels of the input voltage showed a strong dependency on the channel length, while the lateral substrate resistance from a latch-up path in the CMOS inverter was comparable to that of a typical CMOS inverter with a guard ring.

DSP를 이용한 DC 모타에 대한 가변구조 위치제어기 설계 (The design of the variable structure position controller for a DC servo motor using Digital Signal Processor)

  • 박귀태;강문호;이영;문일남;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.319-323
    • /
    • 1990
  • VSS controller is suited for systems where the robust performances in the presence of parameter variations and disturbances are most important. The practical realization of such robust VSS algorithm using DSP ($TMS_{32020}$) is dicussed in this paper. PWH-like control signal which is produced by directly using VSS control algorithm substitutes the PWM amplifier. And the armature current is used in construction of switching function for the purpose of increasing switching frequency. In order to compensate steady state error produced by various external disturbances practical integral compensator is considered.

  • PDF

LLC 공진형 컨버터 제어시스템 설계 (Design of Control System for LLC Resonant Converter)

  • 김의현;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.129-137
    • /
    • 2017
  • 본 논문에서는, 스위칭 손실이 적고 효율이 높은 이점을 갖고 있는 LLC 공진형 컨버터에 대하여 선형화된 수학적 모델을 정립하고 디지털 제어기 설계 과정을 제안한다. LLC 공진형 컨버터의 비선형 모델에 대하여 EDF(Extended Describing Function) 기법을 도입하여 비선형성을 선형 근사화시킨 선형 소신호 모델을 정립하고 Ziegler Nichols 방법을 이용하여 제어기 계수를 선정하였으며 연속시간 제어기를 디지털 제어기로 변환하여 적용한다. 유도된 선형 소신호 모델에 기반하여 전압 제어기를 설계하고, MATLAB 시뮬레이션을 통하여 제어기의 성능을 검증한다. 또한, 부하 변화 및 모델링 오차를 고려한 시뮬레이션을 통하여 LLC 공진형 컨버터에 대해 설계된 전압 제어기의 타당성 및 제어성능을 분석한다.

Finite State Model-based Predictive Current Control with Two-step Horizon for Four-leg NPC Converters

  • Yaramasu, Venkata;Rivera, Marco;Narimani, Mehdi;Wu, Bin;Rodriguez, Jose
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1178-1188
    • /
    • 2014
  • This study proposes a finite-state model predictive controller to regulate the load current and balance the DC-link capacitor voltages of a four-leg neutral-point-clamped converter. The discrete-time model of the converter, DC-link, inductive filter, and load is used to predict the future behavior of the load currents and the DC-link capacitor voltages for all possible switching states. The switching state that minimizes the cost function is selected and directly applied to the converter. The cost function is defined to minimize the error between the predicted load currents and their references, as well as to balance the DC-link capacitor voltages. Moreover, the current regulation performance is improved by using a two-step prediction horizon. The feasibility of the proposed predictive control scheme for different references and loads is verified through real-time implementation on the basis of dSPACEDS1103.

임펼스성 잡음이 있을때 협대역 ISDN 가입자 전송로의 통신로 용량 한계 결정 (Determination of Channel Capacity Bounds of Narrow Band ISDN Subscriber Line in the Presence of Impulsive Noise)

  • 이종헌;성태경;진용옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.854-858
    • /
    • 1987
  • This paper considers impulsive noise which produce burst error in high speed(approx.160Kbps) data transmission like ISDN(Integrated Servise Digital Network) using PSTN(Public Switching Telephone Network). To begin with, we obtains the transfer function of subscriber line to calculate the variation of bandwidth when the gain of receiver is fixed and channel capacity of non-gaussian channel in upper-and lower bound, and evaluates the transmission capability. In this paper compares channel capacity bounds which obtains when probability density function of impulsive noise is Laplacian distribution function with impulsive noise generated by waveform synthesier.

  • PDF

Peak-Valley Current Mode Controlled H-Bridge Inverter with Digital Slope Compensation for Cycle-by-Cycle Current Regulation

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.1989-2000
    • /
    • 2015
  • In this paper, digital peak current mode control for single phase H-bridge inverters is developed and implemented. The digital peak current mode control is achieved by directly controlling the PWM signals by cycle-by-cycle current limitation. Unlike the DC-DC converter where the output voltage always remains in the positive region, the output of DC-AC inverter flips from positive to negative region continuously. Therefore, when the inverter operates in negative region, the control should be changed to valley current mode control. Thus, a novel control logic circuit is required for the function and need to be analyzed for the hardware to track the sinusoidal reference in both regions. The problem of sub-harmonic instability which is inherent with peak current mode control is also addressed, and then proposes the digital slope compensation in constant-sloped external ramp to suppress the oscillation. For unipolar PWM switching method, an adaptive slope compensation in digital manner is also proposed. In this paper, the operating principles and design guidelines of the proposed scheme are presented, along with the performance analysis and numerical simulation. Also, a 200W inverter hardware prototype has been implemented for experimental verification of the proposed controller scheme.

위성통신 중계기에서의 FPGA를 이용한 Gigabit 시리얼 송수신기 설계 (A Gigabit Serial Transceiver Design Using FPGA for Satellite Communication Transponder)

  • 홍근표;이정섭;진병일;고현석;서학금
    • 한국통신학회논문지
    • /
    • 제39A권8호
    • /
    • pp.481-487
    • /
    • 2014
  • 본 논문에서는 위성통신 디지털 중계기에서 backplane 구조 기반의 Gigabit 시리얼(Serial) 송수신기(Transceiver)에 대해 기술하였다. 송수신기는 프로그램밍 가능한 Xilinx space-grade Virtex-5 FPGA를 이용하여 다수의 광대역 채널에 대해 모든 경우의 스위칭 기능을 지원한다. 이러한 기능을 구현하기 위해 Virtex-5 FPGA 내부에 탑재된 GTX transceiver(고속 시리얼 송수신)을 사용한다. FPGA를 사용함으로써 부품이 추가되지 않아 구현이 간단해지는 장점이 있다. 고속의 시리얼 송수신기를 구현하기 위해서 PCB 디자인에 대해 신호 무결성(Signal Integrity) 시뮬레이션을 필수적으로 수행하였다. 신호 무결성 시뮬레이션을 통해 GTX 전송 선로에 대한 S-parameter, Eye diagram, 채널 지터(Channel Jitter) 성능을 분석하였고, GTX transceiver가 오류 없이 동작할 것으로 확인하였다. 마지막으로 제안한 PCB 디자인은 위성통신 디지털 중계기 시험인증모델(Engineering Qualification Model-2) 제작에 활용될 것이다.