• Title/Summary/Keyword: Differential Coil

Search Result 66, Processing Time 0.025 seconds

Measuring, Method of the Intial Permeability of Magnetic Powder and Its Applications (자성분말의 초투자율 측정방법과 응용)

  • Jun, Hong-Bae;Heo, Jin;Kim, Chul-Han;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1687-1689
    • /
    • 2000
  • In this study, a measuring system of the initial permeability of soft-ferrite powder was developed by using a differential transformer coil. and was investigated demagnetizing factors. Magnetic powder is extensively used for a magnetic fluid and microwave absorber materials etc. In these applications, it is very important for us to measure the initial permeability of magnetic ceramic powder. Unfortunately there are not any measuring equipment and method directly up to the present.

  • PDF

Degradation Evaluation of Turbine Rotor Using Magnetic Method (자기적 방법에 의한 터빈 로터강의 열화도 평가)

  • Ryu, K.S.;Park, J.S.;Nahm, S.H.;Kim, Y.I.;Yu, K.M.;Ryu, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1593-1595
    • /
    • 2000
  • We present a new procedure to evaluate the degradation in a lCr-lMo-0.25V steel. The method is based on the existence of the peak of reversible permeability in the differential magnetization around the coercive field strength. The apparatus is based on the detection of the voltage induced in a surface type coil using a lock-in amplifier tuned to a frequency to the exciting one. Results obtained the reversible permeability and Vickers hardness on the annealed samples show the peak interval of reversible permeability and Vickers hardness decreased as ageing time increased. The correlation between Vickers hardness and the peak interval of reversible permeability could well be evaluated non destructively.

  • PDF

Tetracycline-incorporated Silk Fibroin Films

  • Kim, Jong-Ho;Shin, Bong-Seob;Jeon, Jong-Young;Kweon, Hae-Yong;Jo, You-Young;Lee, Heui-Sam;Lee, Kwang-Gill
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.25 no.1
    • /
    • pp.129-132
    • /
    • 2012
  • Silk fibroin films incorporated with tetracycline was prepared and characterized by Fourier-transform infrared spectrometer and differential scanning calorimeter and examined antibacterial effect. The conformation of silk fibroin was changed from random coil to $\hat{a}$ sheet structure with incorporation of tetracycline. Antibacterial activity of the materials was evaluated against Gram-negative bacteria (Escherichia coli) and Gram-positive bacteria (Staphylococcus epidermis, and Staphylococcus aures) using agar plate method showing clear inhibition zone around tetracycline silk film. It is concluded that tetracycline-incorporated SF films are highly effective against bacteria.

Electric Properties of YBCO Superconductor (YBCO 세라믹의 전기적 특성)

  • Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.292-293
    • /
    • 2005
  • An electromagnetic memory effect observed in superconducting YBCO system was studied. From the measurement of differential conductance, it was cleared that the mechanism of electromagnetic memory can not be explained by using conventional flux flow model. By changing the density of external magnetic flux, changes in inductance of a coil in which a superconducting bar is inserted were also measured. It was concluded that the electromagnetic memory effect aries from the interaction between the trapped magnetic flux and the weak link of the filament formed in the superconducting bar.

  • PDF

PEGylation of Silk Fibroin Model Peptide

  • Kweon, Hae-Yong;Jo, You-Young;Yeo, Joo-Hong;Woo, Soon-Ok;Han, Sang-Mi;Lee, Kwang-Gill
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.20 no.2
    • /
    • pp.87-91
    • /
    • 2010
  • Silk fibroin model peptide, alanine pentamer was synthesized through solid-phase method and modified with poly(ethylene glycol). Nuclear magnetic resonance spectrometry and Fourier-transform infrared spectroscopy showed the conformation of alanine pentamer, $\beta$-sheet structure and random coil conformation were not changed with PEGylation. Differential scanning calorimetry showed that relatively strong exothermic peak around $180^{\circ}C$ by PEGylation. No cytotoxicity of PEGylated pentamer was observed by L929 cell proliferation test.

Nondestructive Evaluation for Remanent Life of 1Cr-0.5Mo Steel by Reversible Permeability

  • Ryu, Kwon-Sang;Lee, Yun-Hee;Park, Jong-Seo;Baek, Un-Bong
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.206-209
    • /
    • 2012
  • Peak interval for reversible permeability is presented for nondestructively evaluating the remanent life of 1Cr-0.5Mo steel. The method to measure the peak interval of reversible permeability is based on the value of reversible permeability is the same as the differential value of the hysteresis loop. The measurement principle is based on the first harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to a frequency of the exciting voltage. Results obtained for the peak interval of reversible permeability and Rockwell hardness on the aged samples decrease as aging time and the Larson-Miller parameter increase. We could estimate the remanent life of 1Cr-0.5Mo steel by using the relationship between the peak interval of reversible permeability and the Larson-Miller parameter, nondestructively.

Degradation Evaluation of Mechanical Property for Modified 9Cr-1Mo Steel by Reversible Permeability

  • Bong, Chung-Jong;Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Eun-Kyu
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.42-45
    • /
    • 2011
  • The present work studies a nondestructive evaluation of the degradation of modified 9Cr-1Mo steel using a magnetic method based on the existence of the peaks of reversible permeability (RP) in the differential magnetization around the coercive force. The apparatus is based on detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the AC perturbing field. Results obtained for the reversible permeability and Vickers hardness on the aged samples showed the peak interval of reversible permeability (PIRP) and Vickers hardness decrease as aging time increased. The correlation between Vickes hardness and the PIRP could be used to evaluate degradation of modified 9Cr-1Mo steel.

Calcified Dirofilaria immitis Mimicking Thoracic Foreign Body in a Dog

  • Yeongseok Jeong;Seungjo Park
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.457-463
    • /
    • 2023
  • A 13-year-old neutered male Pomeranian, weighting 3 kg, presented with respiratory distress and depression. Radiographic examination revealed calcified ring-like opacities in the main pulmonary artery, mimicking thoracic foreign bodies. Additionally, right heart and main pulmonary artery enlargement and notable lung infiltrations were also observed. Echocardiography showed coil shaped structures in the main pulmonary artery with increased echogenicity compared to other nearby heartworms, which is consistent with calcified Dirofilaria immitis (heartworms). The dog was diagnosed with caval syndrome, which is the advanced and severe manifestation of heartworm infection. This report presents a rare case of calcified heartworm infection observed during a radiological examination, which resemble foreign bodies. Therefore, chronic heartworm disease should be considered as a differential diagnosis when radiopaque ring-like opacities are observed in the pulmonary artery on thoracic radiographs.

A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing (축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발)

  • Ahn, C.B.;Moon, K.C.;Jeong, G.S.;Nam, K.W.;Lee, J.J.;Sun, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.