• Title/Summary/Keyword: Device-to-device

Search Result 25,588, Processing Time 0.067 seconds

Efficacy of Listeria Innocua Reduction on Enoki Mushrooms by Utilization of an Air Sterilization Device (공기 살균 장치 적용 팽이버섯 재배사의 Listeria Innocua 저감 효과)

  • Lee, Hyun-Dong;Yu, Byeong-Kee;Seo, Da-Som;Kim, Se-Ri;Lee, Chan-Jung;Kwak, Kang-Su
    • Journal of Mushroom
    • /
    • v.19 no.3
    • /
    • pp.210-215
    • /
    • 2021
  • For sterilization of microorganisms of the Listeria genus contaminating enoki mushroom, pilot mushroom grower equipped with air sterilization devices were developed. Sterilization experiments were performed using physical and chemical treatments. Internal temperature and humidity were controlled, maintaining 6.62℃±0.30 in the upper shelves, 6.46℃±0.24 in the middle shelves, and 6.48℃±0.25 in the lower shelves. Humidities were 79.97%±4.42, 79.43%±4.06, and 79.94±4.30%, respectively, with a temperature setting of 6.5℃, and a relative humidity of 75%. A suitable enoki mushroom cultivation stage for air sterilizer application was during the growth stage, with temperature in the 6.5~8.5℃ range, and humidity of 70~80%. At these same internal conditions, the ozone concentration in the mushroom cultivator was found to be 160 ppb during ion-cluster generator operation. After physical sterilization, the Listeria innocua survival rate was 0.1 to 0.9% using ion cluster sterilization, and 9.3 to 10.6% using UV air sterilization. The Listeria innocua survival rates on different materials were 9.3~10.6% on the metal specimen, and 9.9~16.2% on the plastic wrapper. The survival rate was particularly high on the rough side of the plastic wrapper. Ion cluster air sterilization is a labor-saving and effective method for suppressing the occurrence of Listeria bacteria on mushroom growers walls and shelves. For the plastic wrapper, chemical sterilization is more effective than physical sterilization.

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

The Narrative Structure of Terayama Shūji's Sekkyōbushi Misemono Opera Shintokumaru (데라야마 슈지(寺山修司)의 '셋교부시(說敎節)에 의한 미세모노(見せ物)오페라' <신토쿠마루(身毒丸)>의 서사 구조)

  • Kang, Choon-ae
    • (The) Research of the performance art and culture
    • /
    • no.32
    • /
    • pp.489-524
    • /
    • 2016
  • This study examines the birth of a genre, the $Sekky{\bar{o}}bushi$ Misemono Opera, focusing on how it accepted and modernized Katarimono $Sekky{\bar{o}}bushi$. Unlike earlier studies, it argues that Terayama was clearly different from other first-generation Angura artists, in that he rebirthed the medieval story $Sekky{\bar{o}}bushi$ as a modern Misemono Opera. Shintokumaru (1978) was directed by Terayama $Sh{\bar{u}}ji$, a member of the first generation of Japan's 1960s Angura Theatre Movement. It takes as its subject the Katarimono $Sekky{\bar{o}}bushi$ Shintokumaru, a story set to music that can be considered an example of the modern heritage of East Asian storytelling. $Sekky{\bar{o}}$ Shintokumaru is set in Tennoji, Japan. The title character Shintoku develops leprosy as a result of his stepmother's curse and is saved through his fiancee Otohime's devoted love and the spiritual power of the Bodhisattva Avalokitesvara. In this work, Terayama combined the narrative style of $Sekky{\bar{o}}bushi$ with J.A. Caesar's shamanistic rock music and gave it the subtitle 'Misemono Opera by $Sekky{\bar{o}}bushi$'. He transforms its underlying theme, the principle of goddesses and their offspring in a medieval religious world and the modori (return) instinct, into a world of mother-son-incest. Also, the pedestrian revenge scene from $Sekky{\bar{o}}bushi$ is altered to represent Shintokumaru as a drag queen, wearing his stepmother's clothes and mask, and he unites sexually with Sensaku, his stepbrother, and ends up killing him. The play follows the cause and effect structure of $Sekky{\bar{o}}bushi$. The appearance of katarite, a storyteller, propelling the narrative throughout and Dr. Yanagida Kunio is significant as an example of the modern use of self-introduction as a narrative device and chorus. Terayama $Sh{\bar{u}}ji^{\prime}s$ memories of desperate childhood, especially the absence of his father and the Aomori air raids, are depicted and deepened in structure. However, seventeen years after Terayama's death, the version of the play directed by Ninagawa Yukio-based on a revised edition by Kishida Rio, who had been Terayama's writing partner since the play's premier-is the today the better-known version. All the theatrical elements implied by Terayama's subtitle were removed, and as a result, the Rio production misses the essence of the diverse experimental theatre of Terayama's theatre company, $Tenj{\bar{o}}$ Sajiki. Shintokumaru has the narrative structure characteristic of aphorism. That is, each part of the story can stand alone, but it is possible to combine all the parts organically.

Development of integrated microbubble and microfilter system for liquid fertilizer production by removing total coliform and improving reduction of suspended solid in livestock manure (가축분뇨 내 대장균 제거와 부유물질 저감 효율 향상을 통한 추비 생산용 미세기포 부상분리와 마이크로 필터 연계 시스템 개발)

  • Jang, Jae Kyung;Lee, Donggwan;Paek, Yee;Lee, Taeseok;Lim, Ryu Gap;Kim, Taeyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.139-147
    • /
    • 2021
  • Livestock manure is used as an organic fertilizer to replace chemical fertilizers after sufficient fermentation in an aerobic bioreactor. On the other hand, liquid manure disposal problems occur repeatedly because soil spraying is restricted during the summer when the crops are growing. To use liquid fertilizer (LF) as an additional nutrient source for crops, it is necessary to reduce the amount of suspended solids (SS) in the liquid fertilizer and secure stability problems against pathogenic microorganisms. This study examined the effects of the simultaneous SS removal and E.coli sterilization in the LF using the microbubble (MB) generator (FeMgO catalyst insertion). The remaining SS were further removed using the integrated microbubble and microfilter system. During the floating process in the MB device, the SS were removed by 57.9%, and the coliform group was not detected (16,200→0 MPN/100 mL). By optimizing the HRT of the integrated system, the removal efficiency of the SS was improved by 92.9% under the 0.1h of HRT condition. After checking the properties of the treated LF, 64.5%, 70.1%, 54.9%, and 51.5% of the TCOD, SCOD, PO4-P, and TN, respectively, were removed. The treated effluent from such an integrated system has a lower SS content than that of the existing LF and does not contain coliforms; therefore, it can be used directly as an additional fertilizer.

Korea National College of Agriculture and Fisheries in Naver News by Web Crolling : Based on Keyword Analysis and Semantic Network Analysis (웹 크롤링에 의한 네이버 뉴스에서의 한국농수산대학 - 키워드 분석과 의미연결망분석 -)

  • Joo, J.S.;Lee, S.Y.;Kim, S.H.;Park, N.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.23 no.2
    • /
    • pp.71-86
    • /
    • 2021
  • This study was conducted to find information on the university's image from words related to 'Korea National College of Agriculture and Fisheries (KNCAF)' in Naver News. For this purpose, word frequency analysis, TF-IDF evaluation and semantic network analysis were performed using web crawling technology. In word frequency analysis, 'agriculture', 'education', 'support', 'farmer', 'youth', 'university', 'business', 'rural', 'CEO' were important words. In the TF-IDF evaluation, the key words were 'farmer', 'dron', 'agricultural and livestock food department', 'Jeonbuk', 'young farmer', 'agriculture', 'Chonju', 'university', 'device', 'spreading'. In the semantic network analysis, the Bigrams showed high correlations in the order of 'youth' - 'farmer', 'digital' - 'agriculture', 'farming' - 'settlement', 'agriculture' - 'rural', 'digital' - 'turnover'. As a result of evaluating the importance of keywords as five central index, 'agriculture' ranked first. And the keywords in the second place of the centrality index were 'farmers' (Cc, Cb), 'education' (Cd, Cp) and 'future' (Ce). The sperman's rank correlation coefficient by centrality index showed the most similar rank between Degree centrality and Pagerank centrality. The KNCAF articles of Naver News were used as important words such as 'agriculture', 'education', 'support', 'farmer', 'youth' in terms of word frequency. However, in the evaluation including document frequency, the words such as 'farmer', 'dron', 'Ministry of Agriculture, Food and Rural Affairs', 'Jeonbuk', and 'young farmers' were found to be key words. The centrality analysis considering the network connectivity between words was suitable for evaluation by Cd and Cp. And the words with strong centrality were 'agriculture', 'education', 'future', 'farmer', 'digital', 'support', 'utilization'.

Association between physical activity measured using an accelerometer and arterial stiffness based on pulse wave velocity and ankle-brachial index in healthy adults (건강한 성인에서 가속도계로 측정한 신체활동과 맥파전달속도 및 상완-발목 간 혈압비에 기반한 동맥경화지표와의 관계)

  • Lee, Hyunju;Park, Kye Wol;Jun, Ha Yeon;Gwak, Ji Yeon;Kim, Eun Kyung
    • Journal of Nutrition and Health
    • /
    • v.55 no.4
    • /
    • pp.506-520
    • /
    • 2022
  • Purpose: Physical activity (PA) has a beneficial effect on the prevention of arteriosclerosis in healthy adults. The purpose of this study was to analyze the relationship between PA measured using an accelerometer and arterial stiffness in healthy Korean adults. Methods: This study involved 87 subjects (36.8% women) aged 20-64 years. PA was evaluated using an accelerometer (wGT3X-BT, ActiGraph, Florida, USA) for 7 days. Based on the results of the accelerometer measurement, subjects were classified into active and inactive groups according to the World Health Organization (WHO) PA guidelines. The brachial-ankle pulse wave velocity (baPWV) and ankle-brachial index (ABI) to assess arterial stiffness were measured by a non-invasive vascular screening device (VP-1000 Plus, Omron). Results: The average age of the study subjects was 47.7 ± 11.3 years and the WHO PA guideline achievement rate was 29.9%. There was no significant difference in arterial stiffness (baPWV and ABI) between the active and inactive groups. In females, the time spent in light PA were positively correlated with ABI (r = 0.396; p < 0.05) and the number of sedentary bouts over 50 minutes was inversely correlated with ABI (r = -0.402; p < 0.05). However, there was no significant correlation between PA and arterial stiffness in males. Conclusions: The results of this study suggest that light PA and sedentary behavior have a positive correlation with arterial stiffness in females.

Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges (O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • There has been a rapid progress for flexible polymer-based MEMS(Microelectromechanical Systems) technology. Polycarbonate (PC) and Poly Methyl Methacrylate (PMMA), so-called acrylic, have many advantages for optical, non-toxic and micro-device application. We studied dry etching of PC and PMMA as a function of % gas ratio in the $O_2/SF_6/CH_4$ temary plasma. A photoresist pattern was defined on the polymer samples with a mask using a conventional lithography. Plasma etching was done at 100 W RIE chuck power and 10 sccm total gas flow rate. The etch rates of PMMA were typically 2 times higher than those of PC in the whole experimental range. The result would be related to higher melting point of PC compared to that of PMMA. The highest etch rates of PMMA and PC were found in the $O_2/SF_6$ discharges among $O_2/SF_6$, $O_2/CH_4$ and $SF_6/CH_4$ and $O_2/SF_6/CH_4$ plasma composition (PC: ${\sim}350\;nm/min$ at 5 sccm $O_2/5$ sccm $SF_6$, PMMA: ${\sim}570\;nm/min$ at 2.5 sccm $O_2/7.5$ sccm $SF_6$). PC has smoother surface morphology than PMMA after etching in the $O_2/SF_6/CH_4$ discharges. The surface roughness of PC was in the range of 1.9$\sim$3.88 nm. However, that of PMMA was 17.3$\sim$26.1 nm.

Improved Photoelectric Conversion Efficiency of Perovskite Solar Cells with TiO2:TiCl4 Electron Transfer Layer (TiO2:TiCl4 전자수송층을 도입한 페로브스카이트 태양전지의 광전변환효율 향상)

  • Ahn, Joon-sub;Kang, Seung-gu;Song, Jae-gwan;Kim, Jin-bong;Han, Eun-mi
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.85-90
    • /
    • 2017
  • The $TiCl_4$ as a blocking material is adsorbed in the mesoporous $TiO_2$ electron transfer layer(ETL) of the Perovskite solar cell to prevent the direct contact between the FTO electrode and the photoactive layer(AL), and facilitate the movement of the electrons between $TiO_2:TiCl_4$ ETL and Perovskite AL to improve the photoelectric conversion efficiency(PCE). The structure of the perovskite solar cell is FTO/$TiO_2:TiCl_4$/Perovskite($CH_3NH_3PbI_3$)/spiro-OMeTAD/Ag. It was investigated that the dipping time of the $TiO_2$ into $TiCl_4$ aqueous solution affects on the photoelectric characteristics of the device. By the dipping for 30 minutes, the PCE of the perovskite solar cell with the $TiO_2:TiCl_4$ ETL was the highest 10.46%, which is 27% higher than the cell with $TiO_2$ ETL. From SEM, EDS, and XRD characterization on the $TiO_2:TiCl_4$ ETL and the perovskite AL, it was measured that the decrease of the porosity of the $TiO_2$ layer, the detection of the Cl component by the $TiCl_4$ adsorption, the cube-type morphology of perovskite AL, and shift of the $PbI_2$ peak of the perovskite AL. From these results, it was confirmed that the $TiO_2:TiCl_4$ ETL and the perovskite AL were formed.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF