• Title/Summary/Keyword: Deviation ratio

Search Result 907, Processing Time 0.028 seconds

Modeling of Deviation Angle and Pressure Loss Due to Rotor Tip Leakage Flow Effects in Axial Turbines (축류터빈에서 끝간격 유동에 의한 편향각과 압력손실의 모형)

  • Yoon, Eui Soo;Park, Moo Ryong;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1591-1602
    • /
    • 1998
  • Simple spanwise distribution models of deviation angle and pressure loss coefficient due to the tip leakage flow are formulated for use in association with the streamline curvature method as a flow analysis. Combining these new models with the previous deviation and loss models due to secondary flow, a robust streamline curvature method is established for flow analysis of single-stage, subsonic axial turbines with wide ranges of turning angle, aspect ratio and blading type. At the exit from rotor rows, the flow variables are mixed radially according to a spanwise transport equation. The proposed streamline curvature method is tested against a forced vortex type turbine as well as a free vortex type one. The results show that the spanwise variations of flow angle, axial velocity and loss coefficients at rotor exit are predicted with good accuracy, being comparable to a steady three-dimensional Navier-Stokes analysis. This simple and fast flow analysis is found to be very useful for the turbine design at the initial design phase.

Correction of Fluoroscopic Image for Nucleoplasty in Lumbar Disc (요추디스크 수핵감압술을 위한 투시영상의 교정)

  • Yun, Young Woo;Kang, Se Sik;Choi, Seok Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.359-365
    • /
    • 2016
  • Fluoroscopy is performed when tissue or organ in the human body is examined, and it is used for diagnosis and procedure in back ailments. With regard to fluoroscopy equipment, distortion occurs on the peripheral part of fluoroscopic image rather than on its central part. This study measured distortion factors of vertical spacing ratio and distortion factor of diagonal spacing ratio before and after correction by applying a correction algorithm. According to measuring the vertical spacing ratio, post-correction standard deviation decreased by 0.04 in comparison with pre-correction one. Also measuring the diagonal spacing ratio, post-correction standard deviation decreased by 0.06 in comparison with pre-correction one. Consequently, the distortion of fluoroscopic image decreased after correction. A decrease in the distortion of image through the application of correction algorithm and the improvement of performance will be helpful in finding a correct position of lumbar puncture in nucleoplasty to treat lumbar disc herniation in the future.

A Study on the Performance Evaluation and Use Status of Grid (격자의 성능평가와 이용실태에 관한 연구)

  • Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk;Oh, Hyun-Joo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, In-Ja;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 1994
  • We have conducted on experiment with a purpose to evaluate the performance of grids being used at hospitals in Seoul and adjacent cities of Seoul. The results are as follows; Reality of the grids use 1. The focused grids were 105 and the parallel grids were 6 among 111 grids subject to experimenting. 2. The grid interspace material was aluminium of 94 and the remains were wood and bakelite. 3. The umber of Korean products from five companies was 33 and the one of the foreign products was 34 from companies. The physical properties have been examined by the notice of Department of Health and Social Affairs. 4. The intensity of secondary radiation was the highest in 5 : 1 grid ratio. 5. The Bucky factor increased with the increase of grid ratio. The selectivity, the grid improvement factor of grids also increased with increase of the grid ratio. However, with 6 : 1 grid ratio those factors were decreased exceptionally. In measurement of grid density with screen determiners and the beam alignment. 6. In evaluation the results were satifisfied within, 20%. 7. The value of the scale and the value of measurement were within the range of standard deviation, but the value of 103 lines were outranged from the standard deviation with all grid ratio except of 6 : 1 grid ratio.

  • PDF

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Nonlinearity effect on the dynamic behavior of the clayey basin edge

  • Hadi Khanbabazadeh
    • Geomechanics and Engineering
    • /
    • v.36 no.4
    • /
    • pp.367-380
    • /
    • 2024
  • Investigations has shown that the correct estimation of the effective amplification period is as important as the amplification value itself. It gets more important in 2D basins. This study presents a quantitative coefficient for consideration of the nonlinearity effect in terms of amplification value and the shift in its period which is missing or ineffectively considered in the previous studies. To attain this goal, by the application of a time domain fully nonlinear method, the deviation of the more common equivalent linear results from the basin nonlinear behavior under strong ground motions is investigated quantitatively. Also, despite the increase in the damping ratio, the possibility of the increase in the amplification due to the increase in motion strength is shown. To make the results useful in engineering practice, by introducing nonlinearity ratio, the effect of the nonlinearity is quantitatively estimated for two soft and stiff clayey basins with three different depths under a set of motions scaled to two target spectrum. Results show that at the 100 m depth soft clayey basin, while the nonlinearity ratio shows a 35% deviation at the basin edge part under DD1 motion level, its effect moves to the central part with 20% effect under DD3 motion level. By the increase in depth to 150 m, the results show a decrease in the overall effect of the nonlinear behavior for both clay types. At this depth, the nonlinearity ratio gives a 30% and 17% difference on a limited distance from outcrop at the soft clayey basin under DD1 and DD3 motion levels, respectively. At the 30 m depth basins, the nonlinearity ratio shows up to 25% difference for different cases. The presented ratio would be introduced as nonlinearity coefficients for consideration of the nonlinearity effects in the codes. The presented quantitative margins will help the designer to have a better understanding of the amplification period change because of nonlinearity over 2D basin surface.

Relationship between chin deviation and the position and morphology of the mandible in individuals with a unilateral cleft lip and palate

  • Kim, Kyung-Seon;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.168-177
    • /
    • 2013
  • Objective: In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods: Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results: For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions: UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance.

EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE (수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향)

  • Lee, Cheol-Hwan;Cho, Kyung-Mo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

The Frequency Distribution of Void Ratio of Granular Materials (입상체시료의 공극비의 빈도분포)

  • Do, Deok-Hyeon;Go, Jae-Man;O, Gyu-Tae
    • Geotechnical Engineering
    • /
    • v.4 no.3
    • /
    • pp.5-18
    • /
    • 1988
  • This study aims at scrutinizing the relationships among the frequency distribution of voids the relative density and the shear strength for the three types of different granular materials. The main results summarized are as follows: (1) The frequency distribution of void ratio of glass beads can be approximated by the negative exponential distribution proposed by Shahinpoor (1981), while as the particle shape changes from spherical to angular the frequency of the denser voids decreases and the distributions are well presented by the beta distribution. (2) For all materials, the standard deviation of void ratio increases with decreasing both the relative density of the material and sphericity of particle. (3) It was found that shear strength of the material was a function of not only the mean void ratio and its standard deviation, but also of the shape of the probability density function of the distribution of void ratio. The more the frequency distribution of void inclines towards the denser voids, the higher the shear strength of the material and vice versa.

  • PDF

Spray Characteristics on Impingement Angle Variation and Mixture ratio of Impinging Injectors (충돌각과 혼합비 변화에 따른 충돌형 분사기의 분무특성에 관한 연구)

  • Gang, Sin Jae;Song, Beom Geun;Song, Gi Jeong;Lee, Jeong Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.72-79
    • /
    • 2003
  • Spray characteristics were investigated by impinging F-O-O-F type injector with varying the impingement angle through 15, 20 and 30 degree and the mixture ratio(O/F ratio) from 1.5 to 3.0. Experimental results show that the correlation between dispersion and impingement angle is not influenced of the mixture ratio variation, but which has influence on number density, and there is a linear correlation between dispersion and impingement angle. Velocity distribution, standard deviation and SMD of droplets are decreased as the impingement angle increases. Also, it was confirmed that the distribution of droplet size are in accordance with Rosin-Rammler and Upper-limit distribution.

Estimation of the Reactor Volume Ratio for Nitrogen Removal in Step-Feed Activated Sludge Process (단계 주입 활성슬러지공법에서 질소제거를 위한 반응기 용적비 추정)

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.130-136
    • /
    • 2006
  • Theoretical total nitrogen removal efficiency and reactor volume ratio in oxic-anoxic-oxic system can be found by influent water quality in this study. The influent water quality items for calculation were ammonia, nitrite, nitrate, alkalinity, and COD which can affect nitrification and denitrification reaction. Total nitrogen removal efficiency depends on influent allocation ratio. The total nitrogen removal follows the equation of 1/(1+b). Optimal reactor volume ratio for maximum TN removal efficiency was expressed by those influent water quality and nitrification/denitrification rate constants. It was possible to expect optimal reactor volume ratio by the calculation with the standard deviation of ${\pm}14.2$.