Abstract
As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room
Keywords
Daylighting; Light guide; Automated blind systems; Luminance distribution; Luminance ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 송규동, "RADIANCE 프로그램을 이용한 베네치안 블라인드의 차양특성 분석" 한국생태환경건축학회 논문집, 5권 3호, 2006. 9
2 정근영, 최안섭, "RADIANCE 프로그램에 의한 창문 블라인드의 투과율 분석 연구", 조명.전기설비학회 논문집, 17권 6호 2003.11
3 Hiroshi Tamura, ""Measurement and subjective experiments on window systems for controlling sunlight", Dept. of Architect, Tokai University
4 Koster Helmut, "Dynamic Daylighting Architecture : Basics, Systems, Projects", Springer Verlag, 2004
5 IEA SHC Task 21, "Daylighting in Buildings", 1998
6 M. David Egan, "Concepts in Architectural Lighting", 1983
7 William M. C. LAM, "Sunlighting as Formgiver for Architecture", 1999
8 Michael Laar, Lightshelves and Fins-Carrying on Where the Tropical Modernism Lift Off. 7th International IBPSA Conference, 2001, pp.1335-1340
9 www.iea-shc.org
10 심인보, 경희대학교 석사학위논문, "광선반 채광시스템의 시각적 성능 평가", 2006
11 Eleanor Lee et al, "Advancement of Electrochromic Windows", Lawrence Berkeley National Laboratory, 2006
12 Hayashi, T. Watanabe, T, Katayama, T, "Time- Variable Numerical Model of Heat Transfer around Solar Shading Devices in Window", Thermal Performance of the Exterior Envelopes of Building IV, pp. 405-413, 1989
13 문기훈, 김정태, "Lightscape 이용한 광선반채광시스템 채광성능평가", 한국생태환경건축학회논문집, 4권 4호, 2004.12
14 김정태, 신현구, 김곤, "광반사를 이용한 광선반 채광시스템의 기본 형상 설계 및 성능평가에 관한 연구", 대한건축학회논문집, 19권 3호, 2003.3
15 신현구, 경희대학교 석사학위논문, "광반사를 이용한 광선반 채광시스템의 기본형상 설계 및 성능평가에 관한 연구", 2003
16 화영외, '라이트가이드와 블라인드시스템이 통합 적용된 사무소공간의 주광환경특성분석', 한국생태환경건축학회 학술발표대회논문집, 2006.11, pp179-183