• Title/Summary/Keyword: Deviation parameter

Search Result 375, Processing Time 0.027 seconds

Study on Temperature Control and Optimal Design for Continuous Sterilizer (연속 살균기의 온도제어 및 최적설계에 관한 연구)

  • Park, Cheol Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.813-821
    • /
    • 2015
  • In this paper, we analyzed the problems of a batch-type sterilizer and design a continuous sterilizer to control the temperature deviation. The temperature deviation is analyzed with respect to design parameters such as a nozzle diameter, hole diameter, and nozzle length. The significant temperature parameters are optimized using the response surface methodology. An experimental apparatus is developed using the optimized design parameters. Using a field test, we show that the target temperature is obtained in about 7.3 minutes and the temperature deviation is improved about $0.84^{\circ}C$. The optimized parameters from the test are equal to the analytical parameters.

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

A Technique for Accurate Measurement of Power System Frequency (전력설비의 정밀주파수진단을 위한 기법)

  • Nam, S.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Calculating Mean Life of Generators with Aging failures Data Using Data Analytic Method (통계적 분석 방법을 이용한 발전설비의 평균수명 계산)

  • Lee Sung Hoon;Lee Seung Hyuk;Kim Jin O;Jeon Dong Hoon;Kim Tae Kyun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.464-466
    • /
    • 2004
  • This paper proposes a method to consider an aging failure probability and survival probability of power system components unlike uses only aging failure probability in existing mean life calculation. The estimates of the mean and its standard deviation is calculated by using Weibull distribution and each estimated parameters is obtained from Data Analytic Method (Type II Censoring). The parameter estimation using Data Analytic Method is simpler and faster than a traditional calculation method. This paper shows how to calculate the mean life and its standard deviation by the proposed method and illustrates a exactness using real historical records of generator utilities in korea.

  • PDF

A Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

An Iterative Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 반복기법)

  • Nam, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.92-95
    • /
    • 2003
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints. it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Chracteristics of the path deviation of the robot manipulator using the variable structure control method (가변 구조 제어 방식을 이용한 로보트 매니플레이터의 경로 이탈 특성)

  • 이홍규;이범희;최계근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.63-66
    • /
    • 1988
  • In the control of the robotic manipulators, the variable structure control method for the get Point Regualation has a advantage of the insensitivity about parameter variations and disturbances. When the robotic manipulators are controlled by a point-to-point scheme, no path constraint is considered. Thus, the variable structure control method will be effectively applied only if the trajectory of the robot hand is estimated precisely. In this paper, the joint trajectories in the joint space and the hand trajectory in the cartesian space are calculated by the variable structure control method, and an algorithm is suggested to elaborate the deviation error of the robot hand from a straight line path. The result of this study will become a base of the effective path planning about robotic manipulators with the variable structure control concept.

  • PDF

FLUORESCENCE QUENCHING OF BBOT BY ANILINE IN DIFFERENT ORGANIC SOLVENTS

  • Kadadevarmath, J.S.;Giraddi, T.P.;Chikkur, G.C.
    • Journal of Photoscience
    • /
    • v.4 no.3
    • /
    • pp.105-112
    • /
    • 1997
  • The fluorescence quenching of 2, 5-di-(5-tert-butyl-2-benzoxazolyl)-thiophene (BBOT) by aniline in five different solvents namely heptane, hexane, cyclohexane, dioxane and acetonitrile has been carried out at room temperature with a view to understand the quenching mechanisms. The experimental results show positive deviation in the Stern-Volmer plots in all the solvents. In order to interpret these results we have invoked the Ground state complex and sphere of action static quenching models. Using these models various rate parameters have been determined. The magnitudes of these parameters suggest that sphere of action static quenching model agrees well with the experimental results. Hence this positive deviation is attributed to the static and dynamic quenching. Further, with the use of Finite Sink approximation model, it was possible to check these bimolecular reactions as diffusion-limited and to estimate independently distance parameter R$^1$ and mutual diffusion coefficient D. Finally an attempt has been made to correlate the values of R$^1$ and D with the values of the encounter distance R and the mutual diffusion coefficient D determined using the Edward's empirical relation and Stokes-Einstein relation.

  • PDF

Signal-to-Noise Ratio Formulas of a Scalar Gaussian Quantizer Mismatched to a Laplacian Source

  • Rhee, Ja-Gan;Na, Sang-Sin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.384-390
    • /
    • 2011
  • The paper derives formulas for the mean-squared error distortion and resulting signal-to-noise (SNR) ratio of a fixed-rate scalar quantizer designed optimally in the minimum mean-squared error sense for a Gaussian density with the standard deviation ${\sigma}_q$ when it is mismatched to a Laplacian density with the standard deviation ${\sigma}_q$. The SNR formulas, based on the key parameter and Bennett's integral, are found accurate for a wide range of $p\({\equiv}\frac{\sigma_p}{\sigma_q}\){\geqq}0.25$. Also an upper bound to the SNR is derived, which becomes tighter with increasing rate R and indicates that the SNR behaves asymptotically as $\frac{20\sqrt{3{\ln}2}}{{\rho}{\ln}10}\;{\sqrt{R}}$ dB.

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF