• Title/Summary/Keyword: Deviation Index

검색결과 570건 처리시간 0.025초

Crack detection in rectangular plate by electromechanical impedance method: modeling and experiment

  • Rajabi, Mehdi;Shamshirsaz, Mahnaz;Naraghi, Mahyar
    • Smart Structures and Systems
    • /
    • 제19권4호
    • /
    • pp.361-369
    • /
    • 2017
  • Electromechanical impedance method as an efficient tool in Structural Health Monitoring (SHM) utilizes the electromechanical impedance of piezoelectric materials which is directly related to the mechanical impedance of the host structure and will be affected by damages. In this paper, electromechanical impedance of piezoelectric patches attached to simply support rectangular plate is determined theoretically and experimentally in order to detect damage. A pairs of piezoelectric wafer active sensor (PWAS) patches are used on top and bottom of an aluminum plate to generate pure bending. The analytical model and experiments are carried out both for undamaged and damaged plates. To validate theoretical models, the electromechanical impedances of PWAS for undamaged and damaged plate using theoretical models are compared with those obtained experimentally. Both theoretical and experimental results demonstrate that by crack generation and intensifying this crack, natural frequency of structure decreases. Finally, in order to evaluate damage severity, damage metrics such as Root Mean Square Deviation (RMSD), Mean Absolute Percentage Deviation (MAPD), and Correlation Coefficient Deviation (CCD) are used based on experimental results. The results show that generation of crack and crack depth increasing can be detectable by CCD.

GMAW 공정에서 아크 안정성의 실시간 측정 (Real-time estimation of arc stability in GMAW process)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

피보험체계측치(被保險體計測値)의 평가(評價)에 관한 연구(硏究) 제10보(第10報) 심흉비(心胸比) 표준치(標準値)에 관한 연구(硏究) (A Study on the Rating of the Insureds' Anthropometric Data X. A Study on the Standard Cardiothoracic Ratio)

  • 임영훈
    • 보험의학회지
    • /
    • 제7권1호
    • /
    • pp.180-188
    • /
    • 1988
  • A study on the standard cardiothoracic ratio calculated from the photofluorography film of chest in a total of 8,030 insured persons(3,449 men and 4,581 women) was undertaken. The results were as follows: 1) The linear regression equations were formed from the 99% confidence ilmits of actually measured average cardiothoracic ratio by weight index. The cardiothoracic ratios by weight index estimated by above mentioned equations, namely theoretic values of cardiothoracic ratio, should be regarded as the standard cardiothoracic ratios. 2) It seems that the standard cardiothoracic ratio${\pm}10%$ deviation should be regarded as the normal limits of cardiothoracic ratio. 3) The tables of standard cardiothoracic ratio by weight index and the normal limits of cardiothoracic ratio by weight index were presented. 4) The average weight index and cardiothoracic ratio in all males and females were 0.993 and 43.3%, and 0.997 and 46.3% respectively. 5) In order to evaluate the cardiothoracic ratio more accurately, the establishment of the standard cardiothoracic ratio by build is considered to be reasonable.

  • PDF

교대 기초말뚝의 측방유동 판정식에 관한 신뢰성 해석 (Reliability Analysis on the Decision Method of Lateral Flow of Foundation Piles for Abutment)

  • 안종필;김규덕;김일구;최진호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1090-1097
    • /
    • 2008
  • This study conducted the decision method of lateral flow in abutment structures founded on the soft soils and the reliability analysis on the foundation pile for abutment. On the basis of the results, this study proposed the reliability design model. Reliability analysis was conducted by applying second moment method, point estimation method, and expected total cost minimization to lateral movement index, lateral movement decision index, modified lateral movement decision index, and circular failure safety factor for the decision criteria of lateral flow. The reliability index by analysis method had a similar tendency each other. Point estimation method was found as a practical method in the aspect of convenience because it could conduct the analysis only by mean and standard deviation as well as the partial derivative on random variables was not necessary. Optimum reliability index and optimum safety according to increasing in failure factors and load ratio were analyzed and loads and resistance factors of the design criteria of optimum reliability were estimated. It presented rational design model which can consider construction level and stability and economical efficiency overall.

  • PDF

악관절 폐구성 과두걸림의 보존적 치료에 대한 장기적 평가 (Long-term Evaluation of Conervative Treatment for the Patients with TMJ Closed Lock)

  • Mi-Suk Seo;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • 제19권1호
    • /
    • pp.93-103
    • /
    • 1994
  • In order to evaluate thelong-term results of conservative treatment on TMJ closed lock, a follow-up study of thirst-two patients was performed 2 to 7 year after treatment. Evaluating method included the questionnaire, clinical examination, transcranial radiograph and mandibular kinesiography. The results were as follows : Seventy-eight percents of patients reported that symptoms were reduced completely or considerably. Recurrent headache was improved after treatment (72 percents of success rate). There was a significant decrease in VAS after treatment and at follow-up comparing with that of before treatment(p<0.01). Most common variable of Helkimo's clinical dysfunction index at follow-up was impared TMJ function. There was a significant decrease in Fricton's craniomandibular index and dysfunction index(p<0.01) Mean interincisal distance was increased by 14.07mm after treatment and was also increased at follow-up by 2.80mm comparing with that of after treatment(p<0.01). Before treatment, condylar translation measurements of affected and non-affected sides on the transcranial radiograph were 4.89±3.20mm and 9.09±3.73mm respectively and at follow- up examination, those were 14.98±4.77 and 17.05±4.35mm respectively. At follow-up, condylar translation were increased significantly comparing with those of before treatment(p<0.01). In 93.1% of patients, the condylar position of affected side at maximum mouth opening was behind the articular eminence before treatment but the percentage was decreased to 13.8% at follow-up(p<0.01). The pattern and range of mandibular movements at follow-up examination were similar to the typical normal movements. And in 16 cases showing lateral deviation of opening path, the deviation was directed to the affected and non-affected sides with the same frequency.

  • PDF

The Crucial Role of the Establishment of Computed Tomography Density Conversion Tables for Treating Brain or Head/Neck Tumors

  • Yang, Shu-Chin;Lo, Su-Hua;Shie, Li-Tsuen;Lee, Sung-Wei;Ho, Sheng-Yow
    • 한국의학물리학회지:의학물리
    • /
    • 제32권3호
    • /
    • pp.59-69
    • /
    • 2021
  • Purpose: The relationship between computed tomography (CT) number and electron density (ED) has been investigated in previous studies. However, the role of these measures for guiding cancer treatment remains unclear. Methods: The CT number was plotted against ED for different imaging protocols. The CT number was imported into ED tables for the Pinnacle treatment planning system (TPS) and was used to determine the effect on dose calculations. Conversion tables for radiation dose calculations were generated and subsequently monitored using a dosimeter to determine the effect of different CT scanning protocols and treatment sites. These tables were used to retrospectively recalculate the radiation therapy plans for 41 patients after an incorrect scanning protocol was inadvertently used. The gamma index was further used to assess the dose distribution, percentage dose difference (DD), and distance-to-agreement (DTA). Results: For densities <1.1 g/cm3, the standard deviation of the CT number was ±0.6% and the greatest variation was noted for brain protocol conditions. For densities >1.1 g/cm3, the standard deviation of the CT number was ±21.2% and the greatest variation occurred for the tube voltage and head and neck (H&N) protocol conditions. These findings suggest that the factors most affecting the CT number are the tube voltage and treatment site (brain and H&N). Gamma index analyses for the 41 retrospective clinical cases, as well as brain metastases and H&N tumors, showed gamma passing rates >90% and <90% for the passing criterion of 2%/2 and 1%/1 mm, respectively. Conclusions: The CT protocol should be carefully decided for TPS. The correct protocol should be used for the corresponding TPS based on the treatment site because this especially affects the dose distribution for brain metastases and H&N tumor recognition. Such steps could help reduce systematic errors.

가중표준편차를 이용한 비대칭 모집단에 대한 다변량 공정능력지수 (Multivariate Process Capability Indices for Skewed Populations with Weighted Standard Deviations)

  • 장영순;배도선
    • 대한산업공학회지
    • /
    • 제29권2호
    • /
    • pp.114-125
    • /
    • 2003
  • This paper proposes multivariate process capability indices (PCIs) for skewed populations using $T^2$rand modified process region approaches. The proposed methods are based on the multivariate version of a weighted standard deviation method which adjusts the variance-covariance matrix of quality characteristics and approximates the probability density function using several multivariate Journal distributions with the adjusted variance-covariance matrix. Performance of the proposed PCIs is investigated using Monte Carlo simulation, and finite sample properties of the estimators are studied by means of relative bias and mean square error.

분포분할법을 이용한 휴리스틱 공정능력지수의 비교 분석 (Heuristic Process Capability Indices Using Distribution-decomposition Methods)

  • 장영순
    • 품질경영학회지
    • /
    • 제41권2호
    • /
    • pp.233-248
    • /
    • 2013
  • Purpose: This study develops heuristic process capability indices (PCIs) using distribution-decomposition methods and evaluates the performances. The heuristic methods decompose the variation of a quality characteristic into upper and lower deviations and adjust the value of the PCIs using decomposed deviations in accordance with the skewness. The weighted variance(WV), new WV(NWV), scaled WV(SWV), and weighted standard deviation(WSD) methods are considered. Methods: The performances of the heuristic PCIs are investigated under the varied situations such as various skewed distributions, sample sizes, and specifications. Results: WV PCI is the best under the normal populations, WSD and SWV PCIs are the best under the low skewed populations, NWV PCI is the best under the moderate and high skewed populations. Conclusion: Comprehensive analysis shows that the NWV method is most adequate for a practical use.

Three-Parameter Gamma Distribution and Its Significance in Structural Reliability

  • Zhao, Yan-Gang;Alfredo H-S. Ang
    • Computational Structural Engineering : An International Journal
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 2002
  • Information on the distribution of the basic random variables is essential for the accurate evaluation of structural reliability. The usual method for determining the distribution is to fit a candidate distribution to the histogram of available statistical data of the variable and perform appropriate goodness-of-fit tests. Generally, such candidate distributions would have two parameters that may be evaluated from the mean value and standard deviation of the statistical data. In the present paper, a-parameter Gamma distribution, whose parameters can be directly defined in terms of the mean value, standard deviation and skewness of available data, is suggested. The flexibility and advantages of the distribution in fitting statistical data and its significance in structural reliability evaluation are identified and discussed. Numerical examples are presented to demonstrate these advantages.

  • PDF

이차손실함수를 이용한 유동적인 공정수행척도 (Flexible Process Performance Measures by Quadratic Loss Function)

  • 정영배
    • 산업경영시스템학회지
    • /
    • 제18권36호
    • /
    • pp.275-285
    • /
    • 1995
  • In recent years there has been increasing interest in the issue of process centering in manufacturing process, The traditional process capability indices Cp, Cpk and Cpu are used to provide measure of process performance, but these indices do not represent the issue of process centering. A new measure of the process capability index Cpm is proposed that takes into account the proximity to the target value as well as the process variation when assessing process performance. However, Cpm only considers acceptance cost for deviation from target value within specification limits, do not includes economic consideration for rejected items. This paper proposes flexible process performance measures that considered quadratic loss function caused by quality deviation within specification limits, rejection cost associated with the disposition of rejected items, and inspection cost. In this model disposition of rejected items are considered under perfect corrective procedures and the absence of perfect corrective procedures.

  • PDF