Crack detection in rectangular plate by electromechanical impedance method: modeling and experiment  

Rajabi, Mehdi (Department of Mechanical Engineering, Amirkabir University of Technology)
Shamshirsaz, Mahnaz (New Technologies Research Center, Amirkabir University of Technology)
Naraghi, Mahyar (Department of Mechanical Engineering, Amirkabir University of Technology)
Publication Information
Smart Structures and Systems / v.19, no.4, 2017 , pp. 361-369 More about this Journal
Abstract
Electromechanical impedance method as an efficient tool in Structural Health Monitoring (SHM) utilizes the electromechanical impedance of piezoelectric materials which is directly related to the mechanical impedance of the host structure and will be affected by damages. In this paper, electromechanical impedance of piezoelectric patches attached to simply support rectangular plate is determined theoretically and experimentally in order to detect damage. A pairs of piezoelectric wafer active sensor (PWAS) patches are used on top and bottom of an aluminum plate to generate pure bending. The analytical model and experiments are carried out both for undamaged and damaged plates. To validate theoretical models, the electromechanical impedances of PWAS for undamaged and damaged plate using theoretical models are compared with those obtained experimentally. Both theoretical and experimental results demonstrate that by crack generation and intensifying this crack, natural frequency of structure decreases. Finally, in order to evaluate damage severity, damage metrics such as Root Mean Square Deviation (RMSD), Mean Absolute Percentage Deviation (MAPD), and Correlation Coefficient Deviation (CCD) are used based on experimental results. The results show that generation of crack and crack depth increasing can be detectable by CCD.
Keywords
electromechanical impedance method; Structural Health Monitoring; damage index; crack intensity; thin plate; modeling; experiments;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Giurgiutiu, V. (2005), "Damage detection in thin plates and aerospace structures with the electro-mechanical impedance method", Struct. Hlth. Monit., 4(2), 99-118.   DOI
2 Giurgiutiu, V. and Zagrai, A.N. (2002), "Embedded self-sensing piezoelectric active sensors for on-line structural identification", J. Vib. Acoust., 124(1), 116-125.   DOI
3 Khadem, S.E. and Rezaee, M. (2000), "Introduction of modified comparison functions for vibration analysis of a rectangular cracked plate", J. Sound Vib., 236(2), 245-258.   DOI
4 Lee, J.C., Shin, S.W., Kim, W.J. and Lee, C.J. (2016), "Electromechanical impedance based monitoring for the setting of cement paste using piezoelectricity sensor", Smart Struct. Syst., 17(1), 123-134.   DOI
5 Li, G.Q., Chuan-Yao, C. and Yuan-Tai, H. (2005), "Equivalent electric circuits of thin plates with two-dimensional piezoelectric actuators", J. Sound Vib., 286(1-2), 145-165.   DOI
6 Liang, C., Sun, F.P. and Rogers, C.A. (1994), "Coupled electromechanical analysis of adaptive material systems - determination of the actuator power consumption and system energy transfer", J. Intel. Mater. Syst. Struct., 5(1), 12-20.   DOI
7 Rugina, C., Enciu, D. and Tudose, M. (2015), "Numerical and experimental study of circular disc electromechanical impedance spectroscopy signature changes due to structural damage and sensor degradation", Struct. Hlth. Monit., 14(6), 663-681.   DOI
8 Lim, Y.Y. and Soh, C.K. (2013), "Damage detection and characterization using EMI technique under varying axial load", Smart Struct. Syst., 11(4), 349-364.   DOI
9 Min, J., Yi, J.H. and Yun, C.B. (2015), "Electromechanical impedance-based long-term shm for jacket-type tidal current power plant structure", Smart Struct. Syst., 15(2), 283-297.   DOI
10 Min, J., Yun, C.B. and Hong, J.W. (2016), "An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems", Smart Struct. Syst., 17(1), 107-122.   DOI
11 Sepehry, N., Bakhtiari-Nejad, F. and Shamshirsaz, M. (2014), "Thermo-Electro-Mechanical impedance based structural health monitoring of plates", Compos. Struct., 116, 147-164.   DOI
12 Sepehry, N., Shamshirsaz, M. and Bastani, A. (2011), "Experimental and theoretical analysis in impedance-based structural health monitoring with varying temperature", Struct. Hlth. Monit., 10(6), 573-585.   DOI
13 Tarazaga, P.A., Peairs, D.M., Wilkie, W.K. and Inman, D.J. (2006), "Structural health monitoring of an inflatable boom subjected to simulated micrometeoroid/orbital debris damage", Proceedings of SPIE 11th International Symposium on Nondestructive Evaluation for Health Monitoring and Diagnostics, San Diego, USA, February.
14 Zagrai, A.N. and Giurgiutiu, V. (2001), "Electro-mechanical impedance method for crack detection in thin plates", J. Intel. Mater. Syst. Struct., 12(10), 709-718.   DOI
15 Tseng, K.K. and Wang, L. (2005), "Structural damage identification for thin plates using smart piezoelectric transducers", Comput. Method. Appl. Mech. Eng., 194(27-29), 3192-3209.   DOI
16 Wang, X., Ehlers, C. and Neitzel, M. (1996), "Electro-mechanical dynamic analysis of the piezoelectric stack", Smart Mater. Struct., 5(4), 492-500.   DOI
17 Wang, X., Ehlers, C. and Neitzel, M. (1997), "An analytical investigation of static models of piezoelectric patches attached to beams and plates", Smart Mater. Struct., 6(2), 204-213.   DOI
18 Yan, W., Chen, W.Q., Cai, J.B. and Lim, C.W. (2007), "Quantitative structural damage detection using high-frequency piezoelectric signaturesvia the reverberation matrix method", Int. J. Numer. Method. Eng., 71(5), 505-528.   DOI