수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구 (A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW)

  • 김진만;한중석;이선형;양재호;이재봉;김영수
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과 (Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws)

  • 류승범;허성주;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.103-109
    • /
    • 2020
  • 목적: 본 연구의 목적은 임플란트 지대주 나사에 혐기성 나사 고정제의 적용 유무와 나사 종류에 따른 풀림 토크 값의 차이를 평가하는 것이다. 재료 및 방법: 외부 육각형 임플란트 고정체를 사용하였고, 동일한 제조사의 지대주와 지대주 나사가 사용되었다. 지대주 나사는 두 종류로 티타늄 재질의 나사(티타늄 나사)와 텅스텐 카바이드 코팅된 나사(Ebony 나사)가 사용되었다. 티타늄 나사에 아무 처리하지 않은 군(TI군)과 티타늄 나사에 나사 고정제를 사용한 군(TI_AS군), Ebony 나사에 아무 처리하지 않은 군(EB군)과 Ebony 나사에 나사 고정제를 사용한 군(EB_AS군)에 대해 실험을 진행하였다. 총 4가지 군에서 각 10개씩의 임플란트 고정체-지대주 복합체가 사용되었다. 디지털 토크 측정 장비를 사용하여 풀림 토크 값을 측정한 뒤 통계 처리하여 각 군별 비교하였다. 정규성 분포를 만족하여 Two-way ANOVA test (α = .05)를 이용하여 통계 분석하였다. 결과: 각 군에 대한 결과를 살펴보면 TI 군은 20.3 ± 1.6 N.cm, TI_AS 군에서 32.4 ± 6.7 N.cm, EB 군은 20.2 ± 1.5 N.cm, EB_AS 군에서 30.4 ± 4.5 N.cm의 풀림 토크 값을 나타냈다. 결론: 혐기성 나사 고정제를 사용한 경우 티타늄 나사와 ebony 나사 모두에서 고정제를 사용하지 않은 경우 보다 풀림 토크 값이 높게 나타났다. 하지만 두 나사 군 간의 차이는 존재하지 않았다.

임플랜트 지대주 종류가 나사풀림력과 연결부의 안정성에 미치는 영향 (Influence of Implant Abutment Systems on Detorque Value and Screw Joint Stability)

  • 배병룡;최유성;조인호
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.97-109
    • /
    • 2010
  • 연구목적 : 본 연구는 임플랜트 지대주에 동적하중을 가하기 전, 후의 풀림토크 변화를 측정함으로써 수종의 지대주에 가해진 단기간의 교합력이 임플랜트-지대주의 안정성에 영향을 미치는지를 연구하고자 하였다. 재료및 방법 : 임플랜트 고정체는 외부육각구조를 사용하였고, 티타늄합금 지대주, 지르코니아 지대주, 주조 금합금 지대주인 UCLA plastic abutment를 사용하였다. 초기 풀림회전력을 측정하고, 하중을 $10^5$ 회 가한후, 풀림회전력을 측정하였다. 초기 풀림회전력 상실률, 하중후 풀림회전력 상실률, 동적하중에 의한 풀림회전력 상실률을 계산하였다. 결과 : 초기 풀림회전력, 동적 하중후 풀림회전력, 초기 풀림회전력 상실률, 동적 하중후 풀림회전력 상실률, 동적 하중에 의한 풀림회전력 상실률은 각 지대주간 유의한 차이를 나타내지 않았다. 또한, 각 지대주 내에서 동적 하중 전후의 풀림회전력은 통계적으로 유의한 차이를 나타내지 않았다. 결론 : Titanium, zirconia, UCLA 지대주의 초기 나사풀림은 지대주간 유의한 차이가 없음을 알 수 있었고, 초기의 저작력은 하중전후 나사풀림에 큰 영향을 주지 않는다고 생각된다. 또한, UCLA, zirconia, titanium 지대주의 선택시 초기 나사풀림과 관련하여 특정 종류의 지대주 선택을 기피할 필요는 없다고 생각된다.

Comparative study of abutment screw loosening with or without adhesive material

  • Arshad, Mahnaz;Shirani, Gholamreza;Refoua, Sina;Yeganeh, Mohammadreza Rahimi
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.99-103
    • /
    • 2017
  • PURPOSE. The purpose of this study was to achieve more retention and stability and to delay or prevent screw loosening. MATERIALS AND METHODS. Twenty implants (Implantium 3.4 mm, Dentium, Seoul, Korea) were divided into 2 groups (n = 20). In the first group, an adhesive material was applied around the screw of the abutments (test group). In the second group, the screws are soaked in saliva (control group). All the screws were torqued under 30 N/cm, Then, the samples were gone through a cyclic fatigue loading process. After cyclic loading, we detorqued screws and calculated detorque value. RESULTS. In comparison with the control group, all the implant screws in the test group were smeared with the adhesive material, showing significant higher detorque value. CONCLUSION. There are significantly higher detorque values in the group with adhesive. It is recommended to make biocompatible adhesive to reduce screw loosening.

코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구 (Detorque force and surface change of coated abutment screw after repeated closing and opening)

  • 장종석;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.500-510
    • /
    • 2008
  • 연구목적: 최근 지대주 나사에 WC/C 또는 TiN 코팅이 연구되고 있으며, 이들을 금속표면에 코팅 시 마찰계수의 감소와 부식에 대한 저항, 물리적 취약함의 해소 등의 효과를 얻을 수 있으며. 코팅된 지대주 나사에서 마모와 적합도, 풀림력이 향상되었다는 결과들이 보고되고 있다. 본 연구에서는 지대주 나사에 적용된 코팅이 나사 풀림에 미치는 영향을 알아보아 임상적으로 문제가 되고 있는 지대주 나사의 풀림현상을 해소하는데 그 목적이 있다. 연구재료 및 방법: 코팅되지 않은 타이타늄 지대주 나사와 (그룹 A) WC/C (그룹 B)와 TiN (그룹 C)으로 코팅된 지대주 나사의 10회 반복 착탈시 풀림력 및 표면의 변화를 비교해본 결과 다음과 같은 결론을 얻었다. 결과: 1. 반복 착탈 전, 그룹 A는 일정한 방향성을 가진 다소 거친 표면이 관찰되었으 나 그룹 B와 그룹 C는 코팅된 입자들이 관찰되었으며 코팅층이 전체적으로 균일하고 매끈한 모양을 나타내었다. 2. 반복 착탈 전, 그룹 B에 비해 그룹 C의 표면에서 코팅 입자의 크기가 더 크고 두껍게 코팅 된 모양을 나타내었다. 3. 반복 착탈 후, 그룹 A와 그룹 B에서는 지대주 나사 표면의 마모와 변형이 관찰 되었으며 그룹 B에서는 코팅 입자의 탈락 현상을 볼 수 있었다. 4. 반복 착탈 전과 후의 지대주 나사 무게의 변화를 측정한 결과 그룹 A가 가장 큰 감소를 보였으며, 그룹 C가 그룹 B 보다 무게의 변화가 적었으나 두 그룹간 통계적으로 유의한 차이는 없었다. 5. 그룹 B와 그룹 C는 그룹 A에 비해 높은 평균 풀림력을 나타내었고 통계학적으로 유의할 만한 차이가 있었다. 6. 그룹 A에서 그룹B 와 그룹 C보다 평균 풀림력의 감소 경향이 더욱 현저 하게 나타났다. 결론: 결론적으로, WC/C 또는 TiN 코팅된 지대주 나사는 반복적인 사용 후에도 코팅되지 않은 타이타늄 지대주 나사에 비해 뚜렷한 표면 변화를 보이지 않았으며 마모에 대한 저항성이 우수하였고 높은 풀림력을 나타내었다. 따라서 지대주 나사에 WC/C 또는 TiN 코팅을 적용 시 나사 풀림의 문제점을 개선할 수 있을 것으로 사료된다.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향 (Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening)

  • 박재경;정창모;전영찬;윤지훈
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.137-147
    • /
    • 2008
  • 임플랜트 보철물에서 각 구성 요소를 연결하는 나사 풀림 현상이 흔히 발생하고 있다. 나사 풀림을 최소화하기 위해서 연결 구성 부품 사이의 압축력을 최대로 하는 것이 중요한데, 나사 신장의 허용 한계 내에서 조임회전력을 증가시켜 나사 내부의 인장력 즉 전하중을 극대화하기 위해서는 마찰 계수를 감소시켜 초기 조임회전력의 손실을 최소화해야 한다. 건조 윤활제를 나사 표면에 코팅한 나사들이 전하중을 증가시키고 나사 풀림을 감소시키나 나사의 반복체결에 따른 코팅표면의 마모가 문제점으로 지적되고 있다. 최근 내마모성이 우수하며 동시에 나사의 마찰 저항을 최소화할 수 있는 텅스텐 카바이드/탄소 코팅을 이용한 나사가 임상에 사용되고 있으나 실제적으로 연결부 안정성에 미치는 영향에 관한 연구는 미미한 편이다. 이에 본 연구에서는 external butt joint 형태를 가지는 US II 시스템과 one stage용 8도의 internal cone 연결형태의 SS II 시스템 및 11도의 internal cone 연결형태의 GS II 시스템에서 티타늄 합금 나사의 텅스텐 카바이드/탄소 코팅이 지대주 나사 풀림에 미치는 영향을 알아보기 위하여 100만 회 반복 하중 전후의 풀림회전력 및 상실률을 비교한 결과 다음과 같은 결론을 얻었다. 1. 초기 풀림회전력은 티타늄 합금나사보다 텅스텐 카바이드/탄소 코팅 나사를 사용한 경우 작게 나타났으며 (P<.01), 동일 나사를 사용한 경우에는 임플랜트 시스템 간에 차이가 없었다 (P>.05). 2. 반복하중에 따른 풀림회전력의 상실률은 두 나사 모두에서 external butt joint 형태의 US II 시스템이 internal cone 연결형태의 SS II 와 GS II 시스템 보다 크게 나타났으나, SS II 와 GS II 시스템 사이에는 차이를 보이지 않았다 (P<.01). 3. 텅스텐 카바이드/탄소 코팅 나사를 사용한 경우 티타늄 합금 나사에 비해 모든 시스템에서 반복하중 후 풀림회전력 상실률이 작게 나타났으며 (P<.01), 코팅 나사 사용으로 인한 상실률의 감소차는 임플랜트 시스템 간에 차이를 보이지 않았다 (P>.05).

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

회전방지장치와 지대주의 내육각구조가 임플란트로 전달되는 조임 회전력에 미치는 영향 (EFFECT OF A COUNTER-TORQUE DEVICE AND THE INTERNAL HEXAGON OF ABUTMENT ON THE TIGHTENING TORQUE TRANSMITTED TO THE IMPLANT)

  • 이상민;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.223-231
    • /
    • 2003
  • Statement of problem : Little is known about the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Purpose : The purpose of this study was to examine the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Material and Methods : In this study, three types of abutment were used, (1) two-piece conical abutment with hexagon, (2) two-piece conical abutment without hexagon, and (3) one-piece conical abutment without hexagon. The experimental groups were divided into five groups according to the type of abutment and the usage of a counter-torque device. Group I : two-piece conical abutment with internal hexagon was tightened without the use of a counter-torque device. Group II : two-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group III : one-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group IV : two-piece conical abutment with internal hexagon was tightened with the use of a counter-torque device Group V : two-piece conical abutment without internal hexagon was tightened with the use of a counter-torque device. Abutments were tightened 20Ncm torque with the use of manual torque wrench and then torque values were measured by torque-gauge. After the measurement of torque values, all groups were loosened with the use of manual torque wrench and then detorque values were measured by torque-gauge. Results : The results were as follows. 1. There were no differences in torque values among three types of abutment. 2. Regardless of the existence of the internal hexagon of abutment, a counter-torque device decreased the tightening torque transmitted to the implant about 92% 3. In group III showed the highest detorque value, however there were no differences among group I, II, IV and V. Conclusion : Within the limitations of this study, it was concluded that the internal hexagon of abutment has no effect on the tightening torque transmitted to the implant and the detorque value of abutment screw. The use of a counter-torque device is essential to prevent microfracture on the implant-bone interface but has no effect on preload.

풀림토크를 이용한 임플란트 토크조절기의 비교 (Comparison of Implant Torque Controllers using Detorque Value)

  • 허윤혁;조리라;김대곤;박찬진
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.419-432
    • /
    • 2010
  • 현재 임상적으로 여러 형태의 토크 조절기가 사용되고 있고, 토크 조절기에 따라 오차율이 다양하게 보고되고 있는데 제조회사에서 권장하는 적절한 조임력으로 나사가 조여지지 않을 경우 나사 풀림과 이에 따른 파절이 발생하여 결과적으로 보철물과 임플란트 매식체에 합병증이 야기될 수 있으므로 토크 조절기의 정확성이 필수적이다. 본 연구에서는 일정 토크 수준이 넘으면 핸들의 앞 부위가 꺾여지도록 만들어진 토크 최대값 제한 장치(TLD, torque limiting device), 눈금자가 표시되어 있는 활 형태로 조임력의 크기를 조절할 수 있는 토크 표시 장치(TID, torque indicating device), 콘트라앵글 핸드피스 형태에 조임력의 크기를 조절하거나 이미 정해진 조절기를 끼워서 사용하는 콘트라앵글 토크 조절장치(CA, contraangle torque device), 기계적인 토크 발생장치를 이용하여 적정 회전력을 가하는 전자 토크 조절기(ETC, electronic torque controller)등 네 종류의 토크 조절기를 이용하여 제조회사의 지시대로 나사를 조인 후 풀림 토크값을 측정하고 각각의 차이값을 구하여 토크 조절기의 정확도를 비교, 분석하고자 하였다. 콘트라앵글 토크 조절장치(CA)가 가장 측정값에 근접한 결과를 보였으며 토크 최대값 제한 장치(TLD)를 제외한 나머지 세 종류의 토크 조절기의 정확도는 서로 통계적으로 유의한 차이를 보이지 않지만, 토크 최대값 제한 장치(TLD) 의 경우 유의하게 낮은 정밀성을 보였으므로 이는 토크 부여 시 회전 속도에 따른 오차발생 가능성을 보여준다. 토크 표시 장치 (TID), 콘트라앵글 토크 조절장치 (CA) 와 같은 수동 토크 조절기는는 전자식 토크 조절기와 오차 범위 내에서의 유사한 정밀성을 보여주고 있으며 이는 임상에서 보다 주의 깊게 장치를 사용한다면 효과적인 전하중 부여가 가능함을 의미한다.