References
- Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.
- Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, et al. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36.
- Naerti, Quirynen M, van Steenberghe D, Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-45. https://doi.org/10.1016/0022-3913(92)90461-I
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-94. https://doi.org/10.1016/0022-3913(90)90177-E
- Dellinges M, Curtis D. Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations. J Prosthet Dent 1996;75:93-8. https://doi.org/10.1016/S0022-3913(96)90424-2
- Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
- Budynas RG, Nisbett JK. Shigley's mechanical engineering design. 8th ed. New York: McGraw Hill;2008. p. 425-9.
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36.
- Patterson EA, John RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7: 26-33.
- 장종석 등. 코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구. 대한치과보철학회지 2008;46:500-510.
- 김진만, 한중석, 이선형, 양재호, 이재봉, 김영수. 수종 임플랜트 지대 주나사의 반복하중 후 나사풀림에 관한 연구. 대한치과보철학회지 2003;Vol. 41, No. 4:519-531.
- Bickford JH. An introduction to the design and behavior of bolted joints. New York: Marcel Dekker; 1995. p. 515-564. 1991;6:270-276.
-
Jemt T. Linden B, Lekholm U. Failures and complication in 127 consecutively placed fixed partial prostheses supproted by B
$\aa$ nemark implants. Int J Oral Maxillofac Implants 1992;7:513-22. - Lekholm U, Steenbrrghe D, Hermann I, Osseointegrated implants in the treatment of partially edentulous jaws: a prospective five-year multicenter study. Int J Oral Maxillofac Implants 1994;9:627-635.
- Becker W, Becker B. Replacement of maxillary and mandibular molars with single endosseous implant restoration: a retrospective study. J Prosthet Dent 1995;74:51-55. https://doi.org/10.1016/S0022-3913(05)80229-X
- Misch CE. Contemporary Implant Dentistry. Mosby- Year Book. Inc., St. Louiss 1993:669-83.
- Jaarda MJ, Razzoog ME, Gratton DG. Providing optimum torque to implant prostheses: a pilot study. Implant Dent 1993;2:50-2. https://doi.org/10.1097/00008505-199304000-00010
- Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants 1994;9:149-55.
- Tan KB, Nicholls JI. The effect of 3 torque delivery systems on gold screw preload at the gold cylinderabutment screw joint. Int J Oral Maxillofac Implants 2002;17:175-83.
- Theoharidou et al. Abutment Screw Loosening in Single-Implant Restorations: A Systematic Review Theoharidou et al. Int J Oral Maxillofac Implants 2008;23:681-90.
- Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent 2003;90(6):539-46. https://doi.org/10.1016/j.prosdent.2003.09.012
- 김대곤. 수종의 임플란트 토크 조절기의 정확성 비교. 대한치과턱관절기능교합학회지 2008;24(2): 157-168.
- Vallee M, Conrad H, Basu S, Seong W. Accuracy of Friction-Style and Spring-Style Mechanicla Torque Limiting Devices for Dental Implants. J Prosthet Dent 2008;100:86-92. https://doi.org/10.1016/S0022-3913(08)60154-7
- Standlee JP, Caputo AA, Chwu MY, Sun TT. Accuracy of mechanincal torque-limiting devices for implants. Int Oral Maxillofac Implants 2002;17: 220-4.
- Standlee JP, Caputo AA. Accuracy of an electric torque-limiting device for implants. Int J Oral Maxillofac Implants 1999;14:278-81.
- Mitrani R, Nicholls JI, Philips KM, Ma T. Accuracy of electronic implant torque controllers following time in clinical service. Int J Oral Maxillofac Implants 2001;16:394-9.
- Standlee JP, Caputo AA. Accuracy of an electric torque-limiting device for implants. Int J Oral Maxillofac Implants 1999;14:278-81.
- Gollen KL, Vermilyea SG, Vossought J, Agar JR. Torque generated using hand held screwdrivers and torque drivers for osseointegrated implants. Proceedings of the Eight Annual Meeting of the Academy of Osseointegration. San Diego, CA, 1993. p.103-4.
- Gutierrez K, Nicholls JI, Libman WJ, Buston TJ. Accuracy of the implant torque wrench following time in clinical service. Int J Prosthodont 1997;10(6): 562-567.
- Cehreli M, Akca K, Tonuk E. Accuracy of a Manual Torque Application Device for Morse-Taper Implants: A Technical Note. Int J Oral Maxillofac Implants 2004;19:743-748.
- McCracken MS, Mitchell L, Hegde R, Mavalli MD. Variability of mechanical torque-limiting devices in clinical service at a US dental school. J Prosthodont. 2010;19(1):20-4. https://doi.org/10.1111/j.1532-849X.2009.00524.x