Comparison of Implant Torque Controllers using Detorque Value

풀림토크를 이용한 임플란트 토크조절기의 비교

  • Huh, Yoon-Hyuk (Department of Prosthodontics and Institute of Oral Science, Gangneung-Wonju National University) ;
  • Cho, Lee-Ra (Department of Prosthodontics and Institute of Oral Science, Gangneung-Wonju National University) ;
  • Kim, Dae-Gon (Department of Prosthodontics and Institute of Oral Science, Gangneung-Wonju National University) ;
  • Park, Chan-Jin (Department of Prosthodontics and Institute of Oral Science, Gangneung-Wonju National University)
  • 허윤혁 (강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 조리라 (강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 김대곤 (강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 박찬진 (강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소)
  • Received : 2010.10.25
  • Accepted : 2010.12.25
  • Published : 2010.12.30

Abstract

Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

현재 임상적으로 여러 형태의 토크 조절기가 사용되고 있고, 토크 조절기에 따라 오차율이 다양하게 보고되고 있는데 제조회사에서 권장하는 적절한 조임력으로 나사가 조여지지 않을 경우 나사 풀림과 이에 따른 파절이 발생하여 결과적으로 보철물과 임플란트 매식체에 합병증이 야기될 수 있으므로 토크 조절기의 정확성이 필수적이다. 본 연구에서는 일정 토크 수준이 넘으면 핸들의 앞 부위가 꺾여지도록 만들어진 토크 최대값 제한 장치(TLD, torque limiting device), 눈금자가 표시되어 있는 활 형태로 조임력의 크기를 조절할 수 있는 토크 표시 장치(TID, torque indicating device), 콘트라앵글 핸드피스 형태에 조임력의 크기를 조절하거나 이미 정해진 조절기를 끼워서 사용하는 콘트라앵글 토크 조절장치(CA, contraangle torque device), 기계적인 토크 발생장치를 이용하여 적정 회전력을 가하는 전자 토크 조절기(ETC, electronic torque controller)등 네 종류의 토크 조절기를 이용하여 제조회사의 지시대로 나사를 조인 후 풀림 토크값을 측정하고 각각의 차이값을 구하여 토크 조절기의 정확도를 비교, 분석하고자 하였다. 콘트라앵글 토크 조절장치(CA)가 가장 측정값에 근접한 결과를 보였으며 토크 최대값 제한 장치(TLD)를 제외한 나머지 세 종류의 토크 조절기의 정확도는 서로 통계적으로 유의한 차이를 보이지 않지만, 토크 최대값 제한 장치(TLD) 의 경우 유의하게 낮은 정밀성을 보였으므로 이는 토크 부여 시 회전 속도에 따른 오차발생 가능성을 보여준다. 토크 표시 장치 (TID), 콘트라앵글 토크 조절장치 (CA) 와 같은 수동 토크 조절기는는 전자식 토크 조절기와 오차 범위 내에서의 유사한 정밀성을 보여주고 있으며 이는 임상에서 보다 주의 깊게 장치를 사용한다면 효과적인 전하중 부여가 가능함을 의미한다.

Keywords

References

  1. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.
  2. Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, et al. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36.
  3. Naerti, Quirynen M, van Steenberghe D, Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-45. https://doi.org/10.1016/0022-3913(92)90461-I
  4. Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-94. https://doi.org/10.1016/0022-3913(90)90177-E
  5. Dellinges M, Curtis D. Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations. J Prosthet Dent 1996;75:93-8. https://doi.org/10.1016/S0022-3913(96)90424-2
  6. Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
  7. Budynas RG, Nisbett JK. Shigley's mechanical engineering design. 8th ed. New York: McGraw Hill;2008. p. 425-9.
  8. Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36.
  9. Patterson EA, John RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7: 26-33.
  10. 장종석 등. 코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구. 대한치과보철학회지 2008;46:500-510.
  11. 김진만, 한중석, 이선형, 양재호, 이재봉, 김영수. 수종 임플랜트 지대 주나사의 반복하중 후 나사풀림에 관한 연구. 대한치과보철학회지 2003;Vol. 41, No. 4:519-531.
  12. Bickford JH. An introduction to the design and behavior of bolted joints. New York: Marcel Dekker; 1995. p. 515-564. 1991;6:270-276.
  13. Jemt T. Linden B, Lekholm U. Failures and complication in 127 consecutively placed fixed partial prostheses supproted by B$\aa$nemark implants. Int J Oral Maxillofac Implants 1992;7:513-22.
  14. Lekholm U, Steenbrrghe D, Hermann I, Osseointegrated implants in the treatment of partially edentulous jaws: a prospective five-year multicenter study. Int J Oral Maxillofac Implants 1994;9:627-635.
  15. Becker W, Becker B. Replacement of maxillary and mandibular molars with single endosseous implant restoration: a retrospective study. J Prosthet Dent 1995;74:51-55. https://doi.org/10.1016/S0022-3913(05)80229-X
  16. Misch CE. Contemporary Implant Dentistry. Mosby- Year Book. Inc., St. Louiss 1993:669-83.
  17. Jaarda MJ, Razzoog ME, Gratton DG. Providing optimum torque to implant prostheses: a pilot study. Implant Dent 1993;2:50-2. https://doi.org/10.1097/00008505-199304000-00010
  18. Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants 1994;9:149-55.
  19. Tan KB, Nicholls JI. The effect of 3 torque delivery systems on gold screw preload at the gold cylinderabutment screw joint. Int J Oral Maxillofac Implants 2002;17:175-83.
  20. Theoharidou et al. Abutment Screw Loosening in Single-Implant Restorations: A Systematic Review Theoharidou et al. Int J Oral Maxillofac Implants 2008;23:681-90.
  21. Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent 2003;90(6):539-46. https://doi.org/10.1016/j.prosdent.2003.09.012
  22. 김대곤. 수종의 임플란트 토크 조절기의 정확성 비교. 대한치과턱관절기능교합학회지 2008;24(2): 157-168.
  23. Vallee M, Conrad H, Basu S, Seong W. Accuracy of Friction-Style and Spring-Style Mechanicla Torque Limiting Devices for Dental Implants. J Prosthet Dent 2008;100:86-92. https://doi.org/10.1016/S0022-3913(08)60154-7
  24. Standlee JP, Caputo AA, Chwu MY, Sun TT. Accuracy of mechanincal torque-limiting devices for implants. Int Oral Maxillofac Implants 2002;17: 220-4.
  25. Standlee JP, Caputo AA. Accuracy of an electric torque-limiting device for implants. Int J Oral Maxillofac Implants 1999;14:278-81.
  26. Mitrani R, Nicholls JI, Philips KM, Ma T. Accuracy of electronic implant torque controllers following time in clinical service. Int J Oral Maxillofac Implants 2001;16:394-9.
  27. Standlee JP, Caputo AA. Accuracy of an electric torque-limiting device for implants. Int J Oral Maxillofac Implants 1999;14:278-81.
  28. Gollen KL, Vermilyea SG, Vossought J, Agar JR. Torque generated using hand held screwdrivers and torque drivers for osseointegrated implants. Proceedings of the Eight Annual Meeting of the Academy of Osseointegration. San Diego, CA, 1993. p.103-4.
  29. Gutierrez K, Nicholls JI, Libman WJ, Buston TJ. Accuracy of the implant torque wrench following time in clinical service. Int J Prosthodont 1997;10(6): 562-567.
  30. Cehreli M, Akca K, Tonuk E. Accuracy of a Manual Torque Application Device for Morse-Taper Implants: A Technical Note. Int J Oral Maxillofac Implants 2004;19:743-748.
  31. McCracken MS, Mitchell L, Hegde R, Mavalli MD. Variability of mechanical torque-limiting devices in clinical service at a US dental school. J Prosthodont. 2010;19(1):20-4. https://doi.org/10.1111/j.1532-849X.2009.00524.x